Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

Products of Dold

Dold: monitoring relays, timer relays and safety technology for the control cabinet

Lieske Elektronik supplies the Dold range for B2B use – from stock or at short notice. For help choosing: vertrieb@industry-electronics.de.

2,100+
Dold items with us
310
measuring and monitoring relays
196
timer relays
86
safety relays

E. Dold & Söhne – safety on the DIN rail

Dold is among the leading European suppliers for functional and electrical safety. The range runs from safety switchgear through monitoring and timing technology to power electronics – all for the same place: the DIN rail inside the cabinet.

The focus is where something is measured and switched as a result. A Dold device watches a physical quantity – voltage, current, insulation resistance, phase sequence, speed, temperature, level – and either releases a relay or drops out. That sounds plain, and in an emergency it decides whether a plant stops or takes damage.

With safety technology, verifiability is added: positively driven contacts, dual-channel evaluation, monitoring of the device’s own switching state. Anyone having a machine assessed to standard needs devices whose behaviour in a fault is defined and demonstrable.

What Dold stands for
✓functional safety (emergency stop, guard door, interlock)
✓electrical safety and insulation monitoring
✓safety relays with positively driven contacts
✓timing technology in many functions
✓drive technology: soft start, standstill monitoring
✓electronic and control cabinet enclosures

Product lines

Measuring and monitoring relaysVoltage, current, insulation resistance, phase sequence and failure, speed and standstill, temperature via PTC thermistor, level. The largest group in the Dold range and in ours. Timer relaysOn-delay and off-delay, pulse and clock generators, star-delta, multifunction devices with adjustable range – from fractions of a second into hours.
Safety technologyEmergency-stop and guard-door evaluation, interlocks, key transfer systems, dual-channel evaluation with cross-fault detection. Coupling and interface relaysThe narrow link between controller and power section: pass a signal on potential-free without loading the PLC output.
Motor protection and drivesMotor protection switches, soft starters, standstill monitors and speed monitoring – so a drive starts gently and is proven to stand still before anyone opens a door. Switching and isolatingContactors, circuit breakers and load isolators, some with interlocking – the parts that turn the electronics’ decision into moved current.

Typical applications

Machine and plant buildingGuard-door monitoring, emergency stop, standstill monitors before unlocking – and the timers that stagger a sequence. Control cabinet buildingMonitor phase sequence and phase failure, guard a voltage window, couple power section and control potential-free.
Conveying and drivesSoft start against jerk and belt slip, speed and standstill monitoring on belt and shaft. Buildings and liftsImpulse switches and timer relays for lighting and ventilation, safety circuits in lift and escalator controls.
Insulation monitoringIn unearthed (IT) systems the device reports the first fault before the second turns into a short circuit – in industry as in medical locations the basis of supply reliability. Food, timber, metalHarsh surroundings, many drives, high demands on reliable shutdown – the industries Dold has always been strong in.

Why Dold?

One housing, many functionsMultifunction timers and monitoring relays cover with a single item what would otherwise need several types – which shrinks the spares store. Demonstrable behaviour in a faultPositively driven contacts and dual-channel evaluation are the precondition for a safety function to be assessed and approved.
Narrow devicesMany types are 22.5 mm wide. In a full cabinet, DIN rail space is often the tightest dimension of all. Long availabilityIndustrial devices are bought again for decades. Maintaining a plant from 2005 means needing that exact type – not its successor with a different terminal layout.

Frequently asked

Are Dold items in stock at Lieske Elektronik?Common monitoring and timer relays are held in stock; the rest of the range is available at short notice. Availability is shown on every item.
I only have the old type designation from the wiring diagram.Send it to us. Dold types run for a long time, and where one has been discontinued there is usually a successor with the same terminal layout – we will find it.
Are there volume prices, framework agreements or project prices?Yes. For larger quantities, recurring demand and projects we quote separately – send us the article number and the annual quantity.
Can you advise on selecting safety technology?On choosing the right device, yes. Assessing a machine’s safety function – performance level, risk assessment – belongs to whoever places the machine on the market.
Dold in the shop by category:

► Measuring and monitoring relays  ·  ► Timer relays  ·  ► Industrial relays  ·  ► Safety relays  ·  ► Electronic modules  ·  ► Contactors  ·  ► Motor protection switches  ·  ► Circuit breakers and isolators  ·  ► Soft starters, frequency converters

Request or order Dold devicesTell us the task – what is to be monitored, at what voltage, with what reaction – and we will pick out the right type. Email vertrieb@industry-electronics.de or use the contact form.


Categories with products from Dold



Dold 0000517 EH9997.11 AC/DC24V US=12-70V fault detection relay Dold EH9997.11AC/DC24VUS=12-70V 0000517Dold 0000517 EH9997.11 AC/DC24V US=12-70V fault detection relay
Das Dold EH9997.11AC/DC24VUS=12-70V ist ein Sammelstörmelder für die Überwachung von Industrieanlagen und Gebäuden. Es handelt sich um ein Trennschaltgerät mit Ruhestromprinzip, das bei ...

Lieske Part No.: 525746
Mfg Part No: 0000517
Type: EH9997.11AC/DC24VUS=12-70V
378,84 EUR
Dold 0000517 plus VAT
≈ £315.95  |  ≈ $423.16
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000524 AA7616.24/100 50/60 Hz 110 V 0.15-1000 S Dold 0000524Dold 0000524 AA7616.24/100 50/60 Hz 110 V 0.15-1000 S


Lieske Part No.: 1011249
Mfg Part No: 0000524
203,27 EUR
Dold 0000524 plus VAT
≈ £169.53  |  ≈ $227.05
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000611 IK8800.12 AC50Hz 240V remote switch Dold IK8800.12 AC50HZ 240V 0000611Dold 0000611 IK8800.12 AC50Hz 240V remote switch


Lieske Part No.: 1001305
Mfg Part No: 0000611
Type: IK8800.12 AC50HZ 240V
89,42 EUR
Dold 0000611 plus VAT
≈ £74.58  |  ≈ $99.88
On order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000659 AA7610.21 AC 50/60 Hz 230 V 2–60 s time relay delayed operation Dold AA7610.21 AC50/60HZ 230V 2-60S 0000659Dold 0000659 AA7610.21 AC 50/60 Hz 230 V 2–60 s time relay delayed operation


Lieske Part No.: 1313010
Mfg Part No: 0000659
Type: AA7610.21 AC50/60HZ 230V 2-60S
259,87 EUR
Dold 0000659 plus VAT
≈ £216.73  |  ≈ $290.27
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000670 AA7616.24 AC 50/60 Hz 110 V 0.15–1000 s time relay delayed operation Dold AA7616.24 AC50/60HZ 110V 0,15-1000S 0000670Dold 0000670 AA7616.24 AC 50/60 Hz 110 V 0.15–1000 s time relay delayed operation


Lieske Part No.: 850189
Mfg Part No: 0000670
Type: AA7616.24 AC50/60HZ 110V 0,15-1000S
263,95 EUR
Dold 0000670 plus VAT
≈ £220.13  |  ≈ $294.83
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000671 AA7616.24 AC 50/60 Hz 110 V 0.15 S–30 H Dold 0000671Dold 0000671 AA7616.24 AC 50/60 Hz 110 V 0.15 S–30 H


Lieske Part No.: 1011244
Mfg Part No: 0000671
175,73 EUR
Dold 0000671 plus VAT
≈ £146.56  |  ≈ $196.29
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000676 AA7616.24 AC 50/60 Hz 230 V 0.15–1000 s time relay delayed operation Dold AA7616.24 AC50/60HZ 230V 0,15-1000S 0000676Dold 0000676 AA7616.24 AC 50/60 Hz 230 V 0.15–1000 s time relay delayed operation


Lieske Part No.: 1313007
Mfg Part No: 0000676
Type: AA7616.24 AC50/60HZ 230V 0,15-1000S
263,95 EUR
Dold 0000676 plus VAT
≈ £220.13  |  ≈ $294.83
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000678 AA7616.24 AC 50/60 Hz 230 V 0.15 S–30 H time relay delayed operation Dold AA7616.24AC50/60HZ230V0,15S-30H 0000678Dold 0000678 AA7616.24 AC 50/60 Hz 230 V 0.15 S–30 H time relay delayed operation
Das Dold Zeitrelais AA7616.24AC50/60HZ230V0,15S-30H ist ein ansprechverzögertes Zeitrelais der MINITIMER-Serie, entwickelt für den Einsatz in industriellen Steuerungen und Schaltanlagen. Es dient ...

Lieske Part No.: 297534
Mfg Part No: 0000678
Type: AA7616.24AC50/60HZ230V0,15S-30H
263,95 EUR
Dold 0000678 plus VAT
≈ £220.13  |  ≈ $294.83
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000679 AA7616.24/100 50/60 Hz 230 V 0.15 S–30 H time relay delayed-on Dold AA7616.24/10050/60HZ230V0,15S-30H 0000679Dold 0000679 AA7616.24/100 50/60 Hz 230 V 0.15 S–30 H time relay delayed-on
Das Dold Zeitrelais AA7616.24/10050/60HZ230V0,15S-30H ist ein ansprechverzögertes Zeitrelais der MINITIMER-Serie, entwickelt für den Einsatz in industriellen Steuerungs- und Schaltanlagen. Es dient ...

Lieske Part No.: 114429
Mfg Part No: 0000679
Type: AA7616.24/10050/60HZ230V0,15S-30H
305,31 EUR
Dold 0000679 plus VAT
≈ £254.63  |  ≈ $341.03
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000680 AA7616.24 AC 50/60 Hz 230 V 0.2 s–60 h time relay delayed operation Dold AA7616.24 AC50/60HZ 230V 0,2S-60H 0000680Dold 0000680 AA7616.24 AC 50/60 Hz 230 V 0.2 s–60 h time relay delayed operation


Lieske Part No.: 841315
Mfg Part No: 0000680
Type: AA7616.24 AC50/60HZ 230V 0,2S-60H
283,98 EUR
Dold 0000680 plus VAT
≈ £236.84  |  ≈ $317.21
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000681 AA7616.24 AC50/60Hz 240V 0.15s–30h time relay, delayed operation Dold AA7616.24 AC50/60HZ 240V 0,15S-30H 0000681Dold 0000681 AA7616.24 AC50/60Hz 240V 0.15s–30h time relay, delayed operation


Lieske Part No.: 1153858
Mfg Part No: 0000681
Type: AA7616.24 AC50/60HZ 240V 0,15S-30H
250,19 EUR
Dold 0000681 plus VAT
≈ £208.66  |  ≈ $279.46
On order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000682 AA7616.24 AC 50/60 Hz 240 V 0.2 s–60 h time relay delayed operation Dold AA7616.24 AC50/60HZ 240V 0,2S-60H 0000682Dold 0000682 AA7616.24 AC 50/60 Hz 240 V 0.2 s–60 h time relay delayed operation
Das Dold Zeitrelais AA7616.24 ist ein ansprechverzögertes Relais für den Einsatz in Schaltschränken, ausgelegt für eine Nennspannung von AC 240 V und eine Frequenz von 50/60 Hz. Es dient zur ...

Lieske Part No.: 697766
Mfg Part No: 0000682
Type: AA7616.24 AC50/60HZ 240V 0,2S-60H
283,98 EUR
Dold 0000682 plus VAT
≈ £236.84  |  ≈ $317.21
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000683 AA7616.24 AC50/60Hz 240V 0.15-1000s time relay, delayed-on AA7616.24 Dold 0000683Dold 0000683 AA7616.24 AC50/60Hz 240V 0.15-1000s time relay, delayed-on AA7616.24


Lieske Part No.: 1011245
Mfg Part No: 0000683
175,73 EUR
Dold 0000683 plus VAT
≈ £146.56  |  ≈ $196.29
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000691 AA7616.32 time relay AC50/60Hz 110V 0.15s-30h delayed-on Dold 0000691Dold 0000691 AA7616.32 time relay AC50/60Hz 110V 0.15s-30h delayed-on


Lieske Part No.: 1011277
Mfg Part No: 0000691
175,73 EUR
Dold 0000691 plus VAT
≈ £146.56  |  ≈ $196.29
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000694 AA7616.32 AC50/60Hz 127V 0.15s–30h time relay, delayed-on AA7616.32 Dold 0000694Dold 0000694 AA7616.32 AC50/60Hz 127V 0.15s–30h time relay, delayed-on AA7616.32


Lieske Part No.: 1011279
Mfg Part No: 0000694
175,73 EUR
Dold 0000694 plus VAT
≈ £146.56  |  ≈ $196.29
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000696 AA7616.32 AC 50/60 Hz 230 V 0.15–1000 s time relay delayed operation Dold AA7616.32 AC50/60HZ 230V 0,15-1000S 0000696Dold 0000696 AA7616.32 AC 50/60 Hz 230 V 0.15–1000 s time relay delayed operation


Lieske Part No.: 1580460
Mfg Part No: 0000696
Type: AA7616.32 AC50/60HZ 230V 0,15-1000S
263,95 EUR
Dold 0000696 plus VAT
≈ £220.13  |  ≈ $294.83
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000697 AA7616.32 AC 50/60 Hz 230 V 0.15 s–30 h time relay delayed-on Dold AA7616.32AC50/60HZ230V0,15S-30H 0000697Dold 0000697 AA7616.32 AC 50/60 Hz 230 V 0.15 s–30 h time relay delayed-on
Das Dold Zeitrelais AA7616.32AC50/60HZ230V0,15S-30H ist ein ansprechverzögertes Zeitrelais der MINITIMER-Serie, entwickelt für den Einsatz in industriellen Steuerungen und Schaltschränken. Es dient ...

Lieske Part No.: 328012
Mfg Part No: 0000697
Type: AA7616.32AC50/60HZ230V0,15S-30H
263,95 EUR
Dold 0000697 plus VAT
≈ £220.13  |  ≈ $294.83
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000698 AA7616.32 AC 50/60 Hz 230 V 0.2 s–60 h time relay delayed operation Dold AA7616.32 AC50/60HZ 230V 0,2S-60H 0000698Dold 0000698 AA7616.32 AC 50/60 Hz 230 V 0.2 s–60 h time relay delayed operation
Das Dold Zeitrelais AA7616.32 ist ein ansprechverzögertes Relais für den Einsatz in Schaltschränken, ausgelegt für eine Nennspannung von AC 230 V und eine Frequenz von 50/60 Hz. Es dient zur ...

Lieske Part No.: 624672
Mfg Part No: 0000698
Type: AA7616.32 AC50/60HZ 230V 0,2S-60H
283,98 EUR
Dold 0000698 plus VAT
≈ £236.84  |  ≈ $317.21
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000700 AA7616.32 AC50/60Hz 240V 0.15s–30h time relay, delayed-on Dold AA7616.32 AC50/60HZ 240V 0,15S-30H 0000700Dold 0000700 AA7616.32 AC50/60Hz 240V 0.15s–30h time relay, delayed-on


Lieske Part No.: 1153859
Mfg Part No: 0000700
Type: AA7616.32 AC50/60HZ 240V 0,15S-30H
250,19 EUR
Dold 0000700 plus VAT
≈ £208.66  |  ≈ $279.46
On order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000843 AI 837 DC0.5-1A RW48% undercurrent relay Dold AI 837 DC0,5-1A RW48% 0000843Dold 0000843 AI 837 DC0.5-1A RW48% undercurrent relay


Lieske Part No.: 1312708
Mfg Part No: 0000843
Type: AI 837 DC0,5-1A RW48%
298,43 EUR
Dold 0000843 plus VAT
≈ £248.89  |  ≈ $333.35
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000844 AI 837 AC 50/60 Hz 0.8–1.6 A undercurrent relay Dold AI 837 AC50/60HZ 0,8-1,6A 0000844Dold 0000844 AI 837 AC 50/60 Hz 0.8–1.6 A undercurrent relay


Lieske Part No.: 1774407
Mfg Part No: 0000844
Type: AI 837 AC50/60HZ 0,8-1,6A
298,43 EUR
Dold 0000844 plus VAT
≈ £248.89  |  ≈ $333.35
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000850 AI 837 AC 50/60 Hz 2.5–5 A undercurrent relay Dold AI837AC50/60HZ2,5-5A 0000850Dold 0000850 AI 837 AC 50/60 Hz 2.5–5 A undercurrent relay


Lieske Part No.: 974954
Mfg Part No: 0000850
Type: AI837AC50/60HZ2,5-5A
298,43 EUR
Dold 0000850 plus VAT
≈ £248.89  |  ≈ $333.35
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000853 AI 837 AC 50/60 Hz 4-8 A undercurrent relay Dold AI 837 AC50/60HZ 4-8A 0000853Dold 0000853 AI 837 AC 50/60 Hz 4-8 A undercurrent relay


Lieske Part No.: 1312709
Mfg Part No: 0000853
Type: AI 837 AC50/60HZ 4-8A
298,43 EUR
Dold 0000853 plus VAT
≈ £248.89  |  ≈ $333.35
Made to order · Delivery time approx. 20 workdaysinfo_outline
Dold 0000854 AI 837 DC4-8A RW48% undercurrent relay Dold 0000854Dold 0000854 AI 837 DC4-8A RW48% undercurrent relay


Lieske Part No.: 1010587
Mfg Part No: 0000854
198,70 EUR
Dold 0000854 plus VAT
≈ £165.72  |  ≈ $221.95
Made to order · Delivery time approx. 20 workdaysinfo_outline
1 3 4 5 6 8 10 .. 20 .. 30 .. 40 .. 50 .. 60 .. 70 .. 80 .. 90 92

What needs to be monitored?

Choosing a monitoring relay rarely starts with the type code. It starts with the question of which quantity is watched, and what should happen when it leaves the permitted range. The short version:

  • Voltage too high, too low or gone – voltage monitoring, single- or three-phase. Often combined with phase sequence and phase failure in one device: a reversed rotating field runs a motor backwards, and on a pump that only shows when nothing is delivered.
  • Current outside the window – current monitoring. Undercurrent is often the more telling signal: it shows the broken belt, the agitator running in an empty vessel, the tool that fell off.
  • Insulation resistance dropping – insulation monitoring for unearthed systems. It reports the FIRST fault while the plant is still running; without it, the fault only shows with the second one, and then as a short circuit.
  • Motor getting too warm – PTC thermistor tripping unit. It measures inside the motor rather than at the supply current, and therefore catches what a motor protection switch cannot see: blocked ventilation, too many starts, high ambient temperature.
  • Shaft must stand still before anyone opens the door – standstill monitor, usually together with an interlock. A drive being switched off does not mean it has stopped.
  • Something should switch delayed, pulsed or staggered – timer relay. Multifunction types cover a dozen functions and several time ranges, replacing a whole drawer of single-purpose devices.
  • Evaluating emergency stop or a guard door – safety switchgear with positively driven contacts. Which design is required follows from the performance level demanded of the safety function.

You know the task but not the type? Tell us both – the quantity, the range and the reaction you want – and we will pick out the right item.

Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
We use cookies to provide the service. Using this website you agree with that. Information on the privacy policy OK und schließen

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.