Aufzugnotruftelefone
Lift emergency phones are legally required and must comply with European standard DIN EN 81-28 ('Remote alarm on passenger and goods passenger lifts'). The standard requires that trapped persons can contact an emergency call centre at all times – including during mains failure. Technically, this is achieved via a 72-hour backup battery, automatic redial to at least two emergency numbers and two-way communication (hands-free). Our range includes lift emergency phones for analogue PSTN connections, GSM/LTE (mains-failure proof) and IP/SIP-based solutions. FHF Funke+Huster Fernsig is one of the leading German manufacturers of standards-compliant lift emergency phones with TÜV certification. |
Top sellers in Elevator Emergency Phones
Elevator Emergency Phones from Telecom Behnke
|
Telecom Behnke 20-3115 Behnke module with microphone and button 1 lift emergency with bell symbol
Module with microphone down button 1 lift emergency with bell symbol above illuminated.Construction: aluminum. Lieske Part No.: 599371 Mfg Part No: 20-3115 |
91,44 EUR
![]() plus delivery charges
Delivery time from supplier's stock (ca.) 6 workdaysinfo_outline
|
|
Telecom Behnke 20-9215 Behnke language module for rear size 1 (small) with connection board
Voice Module Size 1 (small)- Hinterbaumodul, such as sound systems in elevator cars. - Incl. Connection board. - An existing emergency button can be connected to the voice module. - Patch ... Lieske Part No.: 516737 Mfg Part No: 20-9215 |
60,64 EUR
![]() plus delivery charges
Delivery time from supplier's stock (ca.) 6 workdaysinfo_outline
|
|
Telecom Behnke 20-9217 Behnke language module for rear size 2 (medium) with connection board
Voice Module Size 2 (medium)- Hinterbaumodul, such as sound systems in elevator cars. - Incl. Connection board. - An existing emergency button can be connected to the voice module. - Patch ... Lieske Part No.: 839536 Mfg Part No: 20-9217 |
61,60 EUR
![]() plus delivery charges
Delivery time from supplier's stock (ca.) 6 workdaysinfo_outline
|
|
Telecom Behnke 20-9219 Behnke language module for rear size 3 (large) with connection board
Voice module size 3 (large) - Hinterbaumodul, such as sound systems in elevator cars.- Incl. Connection board. - An existing emergency button can be connected to the voice module. - Patch ... Lieske Part No.: 879617 Mfg Part No: 20-9219 |
65,45 EUR
![]() plus delivery charges
Delivery time from supplier's stock (ca.) 6 workdaysinfo_outline
|
|
Telecom Behnke 20-9405 Sticker lift emergency (four pieces)
Sticker lift emergency (four pieces) stickers for mounting on the panel in the elevator car. - On the sticker that are installed in each elevator Behnke features (emergency voice / Viaualnotruf / ...Lieske Part No.: 545760 Mfg Part No: 20-9405 |
12,51 EUR
![]() plus delivery charges
Delivery time from supplier's stock (ca.) 6 workdaysinfo_outline
|
|
Telecom Behnke 20-9506 Behnke DC / DC converter
. BNOS-DC/DC-WandlerThe BNOS-DC/DC-Wandler is a companion board for the BNOS elevator emergency telephone 20-0020 Behnke and other phones and offers The Possibility of a 24V to 12V conversion and ... Lieske Part No.: 773856 Mfg Part No: 20-9506 |
on request
plus delivery charges
Delivery time from supplier's stock (ca.) 6 workdaysinfo_outline
|
|
Telecom Behnke 21-3115 Behnke module with microphone and button 1 lift emergency with bell symbol
Module with microphone down button 1 lift emergency with bell symbol above illuminated.Version: V2A style. Lieske Part No.: 706449 Mfg Part No: 21-3115 |
107,80 EUR
![]() plus delivery charges
Delivery time from supplier's stock (ca.) 6 workdaysinfo_outline
|
Aufzugnotruftelefone – Technical Background & Applications
Lift emergency phones are legally required and must comply with European standard DIN EN 81-28 ('Remote alarm on passenger and goods passenger lifts'). The standard requires that trapped persons can contact an emergency call centre at all times – including during mains failure. Technically, this is achieved via a 72-hour backup battery, automatic redial to at least two emergency numbers and two-way communication (hands-free). Our range includes lift emergency phones for analogue PSTN connections, GSM/LTE (mains-failure proof) and IP/SIP-based solutions. FHF Funke+Huster Fernsig is one of the leading German manufacturers of standards-compliant lift emergency phones with TÜV certification.
Lift emergency phones must be regularly maintained and tested – per DIN EN 81-28 at least every 3 months. When selecting, consider not only standards compliance but also connection type (analogue/GSM/IP), protection class, installation dimensions and remote diagnostics capability. Related products: Emergency phones and Industrial phones. Expert advice on DIN EN 81-28-compliant equipment: +49 (0)7666 / 88499-0, sales@industry-electronics.com.
Application Areas
| ✓ Business Telephony & Call Centres | ✓ Authorities & Public Institutions |
| ✓ Industrial Environments & Production Halls | ✓ Hotels & Hospitality |
| ✓ Hospitals & Care Facilities | ✓ Data Centres & IT Infrastructure |
Frequently Asked Questions
▶ Which standard applies to lift emergency phones in Germany? DIN EN 81-28 (2018 edition) is the definitive European standard for remote alarm systems in passenger and goods lifts. It specifies: 72-hour standby power on mains failure, automatic redial to at least 2 emergency numbers, acoustic confirmation of connection, two-way hands-free communication, and test intervals of maximum 3 months. Additionally, Lift Directive 2014/33/EU and the German BetrSichV apply. |
▶ Can lift emergency phones be operated via GSM/LTE? Yes – GSM/LTE-based lift emergency phones are permitted under DIN EN 81-28 and offer the advantage of operating independently of an analogue PSTN connection. With analogue lines being phased out (All-IP migration), GSM models are particularly future-proof. Network coverage at the installation point (external antenna if needed) and integration into 24/7 monitoring should be considered. |
▶ What must be demonstrated at the annual lift inspection regarding the emergency phone? Per DIN EN 81-28 and BetrSichV, the inspection by an approved body (TÜV, DEKRA) must verify: two-way communication function, correct connection to emergency call centre, backup power function (72h), connection confirmation for the trapped person, and logging of the last test activation. A complete test log (at least every 3 months) is mandatory. |
Why industry-electronics.de?
▶ Professional TK Range Over 15,000 telecoms products from Agfeo, Auerswald, Snom, Yealink, Innovaphone, Gigaset and other leading manufacturers. | ▶ B2B Expert Advice Our TK team advises on SIP migration, DECT planning, emergency call systems and standards compliance – free and vendor-neutral. | ▶ Volume Pricing from 1 Unit Quantity discounts, project prices and framework agreements for system integrators, authorities and industrial companies. |
▶ Fast Delivery Most items available from stock – free shipping across Germany from minimum order value. | ▶ 20+ Years TK Experience For over 20 years, Industry-Electronics has supplied system houses, authorities and industrial customers with professional telecoms technology. | ▶ Standards-Compliant Range All products comply with applicable EN, ETSI and VDE standards and regulatory approvals for commercial use. |









