Rittal 7979239 PDU metered, 32A/400V, 3~, 12 x C13 + 12 x C19
|
899,42 EUR 911,72 EUR |
|
|
( 1.070,31 EUR incl. VAT ) ≈ £752.81 | ≈ $988.46 plus delivery charges: 100,00 € |
|
| Made to order · Delivery time approx. 5 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 1101056 |
| Mfg Part No: | 7979239 |
| UPC/EAN: | 4028177947795 |
| Weight: | 5.8 kg |
| Type: | DK 7979239 |
Product information for Rittal 7979239:
Applications
The PDU is designed for use in IT infrastructures, particularly in data centers, server rooms, and network racks, where precise energy consumption control and optimization are required. Measurement is performed per phase and feed, enabling the total consumption of an entire IT rack to be recorded. The integrated real-time clock with battery backup (up to 10 years, replaceable) ensures continuous time measurement even during power failure. Measurement accuracy is ±1 % (kWh) according to standard EN 62053-21, ensuring reliable data collection for energy balances and cost accounting.
Functions and Equipment in Detail
The device features 12 socket outlets of type C13 and 12 socket outlets of type C19, enabling flexible connection of various IT devices. The rated operating voltage is 400 V (AC), with a maximum rated current of 32 A, corresponding to a rated power of 22 kW. The integrated CPU (ARM Cortex A8) enables powerful data processing. Additionally, it includes a bright TFT display (128x128 pixels, RGB, with backlight) and position sensors for correct display of the PDU position on the web interface. Phases and fuse circuits are color-coded (L1=pink, L2=black, L3=white), facilitating identification and maintenance.
Technology Explained Simply
The PDU continuously measures voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current. Fuse monitoring enables detection of faults in integrated fuses. An integrated electromagnetic buzzer provides acoustic alarm in case of exceedances. Adjustable thresholds for voltage, current, and power allow individual configuration of warning and alarm limits. An operating hour counter (total and cyclic, resettable) documents operating time. The power-saving design ensures low self-consumption.
Compatibility and Accessories
The PDU is designed for Rittal VX IT enclosures with a cabinet frame from 1,800 mm or 19-inch profile rails from 2,000 mm. Optionally, surge protection modules Type 3 with replaceable discharge elements during operation and status monitoring can be integrated. Differential current measurement (Type B) is possible per feed, phase, or fuse. Monitoring of the optional surge protection is also integrated. Up to 16 CMC III CAN-Bus sensors can be connected to monitor environmental parameters such as temperature, air humidity, or smoke. Connection is via a CAN-Bus interface (RJ45), with up to 6 RJ45 ports available for sensor units. Compatible accessories include CAN-Bus cables in various lengths, covers for C13 and C19 socket outlets, mounting adapters, universal locking mechanisms, numeric code locks, transponder readers, and online comfort handles.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT- or TS IT-racks. The delivery includes the fastening material. The connection cable (CEE, 3 m) is connected directly to the feed. The PDU is designed for vertical mounting, with the display unit being rotatable and replaceable by 180° to ensure optimal operability.
Operational Advantages
The PDU offers a fully redundant Ethernet interface (10/100/1000 Mbit/s) and supports numerous protocols such as HTTP/HTTPS, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, FTP/SFTP. Integration into DCIM software is possible via MIB. User management with rights management, LDAP(S)/Radius/Active Directory integration, and Syslog server connection (up to 2 servers) enables centralized administration. Integrated email alarms (SMTP) and an additional relay output (changeover contact) for external alarm systems are provided. The operating temperature range is between 5 °C and 50 °C, with relative humidity (non-condensing) between 10 % and 95 %. The storage temperature range is -20 °C to 70 °C. The PDU complies with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21.
| General | |
| Model | PDU, metered |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | Overvoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available |
| Description of measurement functions | measurement per phase or input, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact) |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.695 mm |
| Number of sockets and type | 12 x C13 / 12 x C19 |
| Rated operating voltage | 400 V (AC) |
| Rated current (max.) | 32 A |
| Nominal power | 22 kW |
| Power supplies | Number: 1, phases per input: 3~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Number of RJ45 ports for sensor units max | 6 |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,800 mm, housing type: VX IT 19"-profile rails: ≥ 2,000 mm |
Questions & answers
What is the delivery time of Rittal 7979239 PDU metered, 32A/400V, 3~, 12 x C13 + 12 x C19?
The article Rittal 7979239 PDU metered, 32A/400V, 3~, 12 x C13 + 12 x C19 is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Rittal 7979239 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Rittal 7979239 PDU metered, 32A/400V, 3~, 12 x C13 + 12 x C19 always at the best possible price. We can give you a discount of 2% on Rittal 7979239 PDU metered, 32A/400V, 3~, 12 x C13 + 12 x C19 if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Rittal 7979239 PDU metered, 32A/400V, 3~, 12 x C13 + 12 x C19
|
Rittal 7030090 Monitoring system CMC III CAN-Bus cable RJ45 0.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360234 Mfg Part No: 7030090 Type: DK 7030090 |
8,40 EUR
![]() ≈ £7.03 | ≈ $9.23
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360235 Mfg Part No: 7030091 Type: DK 7030091 |
10,01 EUR
![]() ≈ £8.38 | ≈ $11.00
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030092 Monitoring system CMC III CAN-Bus cable RJ45 1.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360238 Mfg Part No: 7030092 Type: DK 7030092 |
-11% 11,62 EUR 13,05 EUR
![]() ≈ £9.73 | ≈ $12.77
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Rittal 7030093 Monitoring system CMC III CAN-Bus connection cable
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360246 Mfg Part No: 7030093 Type: DK 7030093 |
13,23 EUR
![]() ≈ £11.07 | ≈ $14.54
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955010 Coverings PDU socket strip C13 socket 10 pcs
The DK 7955010 from Rittal is a socket cover for IEC 60 320 C13 sockets, used in PDU socket strips (Power Distribution Units). The product is designed to securely close unused sockets, preventing ...Lieske Part No.: 981045 Mfg Part No: 7955010 Type: DK 7955010 |
132,03 EUR
![]() ≈ £110.51 | ≈ $145.10
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955015 Coverings PDU socket strip C19 socket 10 pcs
The DK 7955015 socket cover from Rittal is a special accessory designed for use with PDU socket strips (Power Distribution Units). It is intended for the secure closure of open, unused IEC 60 320 C19 ...Lieske Part No.: 981047 Mfg Part No: 7955015 Type: DK 7955015 |
-12% 9,51 EUR 10,82 EUR
![]() ≈ £7.96 | ≈ $10.45
Made to order · Delivery time approx. 5 workdaysinfo_outline
|
|
Rittal 7000688 Mounting adapter PDU TE 8000 2 pcs
The Rittal mounting adapter DK 7000688 is designed for securing a Power Distribution Unit (PDU) to a horizontal system chassis in the VX IT enclosure type. It is specifically designed for integrating ...Lieske Part No.: 999510 Mfg Part No: 7000688 Type: DK 7000688 |
12,88 EUR
![]() ≈ £10.78 | ≈ $14.16
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979020 PDU universal lock for C14/C20 plugs
The DK 7979020 is a plug lock from the manufacturer Rittal, specifically designed for secure fixation of IEC 60 320 C14 and C20 plugs in PDU- or PSM-modules equipped with C13/C19 sockets. This lock ...Lieske Part No.: 1101023 Mfg Part No: 7979020 Type: DK 7979020 |
26,80 EUR
![]() ≈ £22.43 | ≈ $29.45
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030223 Number code lock for CMC III
The Rittal DK 7030223 is a numeric code lock for access control on enclosure doors, specifically designed for use with the CMC III system. It enables secure and controlled access authorization to ...Lieske Part No.: 1775554 Mfg Part No: 7030223 Type: DK 7030223 |
203,92 EUR
![]() ≈ £170.68 | ≈ $224.11
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030233 VX IT CMC III transponder reader, RAL 9005
The Rittal IT 7030233 is a transponder reader for access control at doors, particularly at VX IT doors and side room doors. It is used for secure release of rack, room, or enclosure doors and is ...Lieske Part No.: 1775580 Mfg Part No: 7030233 Type: IT 7030233 |
337,80 EUR
![]() ≈ £282.74 | ≈ $371.24
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979724 Surge protection module for end device protection
The Rittal surge protection module Type 3, model DK 7979724, is a compact protection device for end-device protection in electrical installations. It serves as the final stage in the surge protection ...Lieske Part No.: 1775586 Mfg Part No: 7979724 Type: DK 7979724 |
235,28 EUR
![]() ≈ £196.93 | ≈ $258.57
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030611 CMC III online comfort handle VX with Master-Key function
The Rittal IT 7030611 is a CMC III Online comfort handle VX with Master-Key function, specifically developed for use on VX and VX IT enclosures. It provides secure door locking, monitoring of the ...Lieske Part No.: 1775710 Mfg Part No: 7030611 Type: IT 7030611 |
-12% 240,01 EUR 272,99 EUR
![]() ≈ £200.89 | ≈ $263.77
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|