| General |
| Model | PDU, metered |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | Overvoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available |
| Description of measurement functions | measurement per phase or input, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact) |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.695 mm |
| Number of sockets and type | 12 x C13 / 12 x C19 |
| Rated operating voltage | 400 V (AC) |
| Rated current (max.) | 32 A |
| Nominal power | 22 kW |
| Power supplies | Number: 1, phases per input: 3~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Number of RJ45 ports for sensor units max | 6 |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,800 mm, housing type: VX IT 19"-profile rails: ≥ 2,000 mm |
The Rittal DK 7979239 is a
PDU (Power Distribution Unit) with
energy measurement and integrated network interface, specifically designed for use in IT network and server racks. The device serves for power distribution and monitoring in 19-inch enclosures and enables precise measurement of electrical parameters per phase or feed. The compact design with a length of 1,695 mm, width of 44 mm, and depth of 70 mm allows vertical mounting in the Zero-U-Space of Rittal VX IT- or TS IT-racks, with tool-free installation. The enclosure is made of
aluminum profile, black anodized, and the socket outlets are made of
plastic. Power supply is via a CEE connection cable with a length of 3 m, and the device is self-powered, requiring no external power supply.
Applications
The PDU is designed for use in IT infrastructures, particularly in data centers, server rooms, and network racks, where precise energy consumption control and optimization are required. Measurement is performed per phase and feed, enabling the total consumption of an entire IT rack to be recorded. The integrated real-time clock with battery backup (up to 10 years, replaceable) ensures continuous time measurement even during power failure. Measurement accuracy is ±1 % (kWh) according to standard
EN 62053-21, ensuring reliable data collection for energy balances and cost accounting.
Functions and Equipment in Detail
The device features 12 socket outlets of type
C13 and 12 socket outlets of type
C19, enabling flexible connection of various IT devices. The rated operating voltage is 400 V (AC), with a maximum rated current of 32 A, corresponding to a rated power of 22 kW. The integrated CPU (ARM Cortex A8) enables powerful data processing. Additionally, it includes a bright TFT display (128x128 pixels, RGB, with backlight) and position sensors for correct display of the PDU position on the web interface. Phases and fuse circuits are color-coded (L1=pink, L2=black, L3=white), facilitating identification and maintenance.
Technology Explained Simply
The PDU continuously measures voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current. Fuse monitoring enables detection of faults in integrated fuses. An integrated electromagnetic buzzer provides acoustic alarm in case of exceedances. Adjustable thresholds for voltage, current, and power allow individual configuration of warning and alarm limits. An operating hour counter (total and cyclic, resettable) documents operating time. The power-saving design ensures low self-consumption.
Compatibility and Accessories
The PDU is designed for Rittal VX IT enclosures with a cabinet frame from 1,800 mm or 19-inch profile rails from 2,000 mm. Optionally,
surge protection modules Type 3 with replaceable discharge elements during operation and status monitoring can be integrated.
Differential current measurement (Type B) is possible per feed, phase, or fuse. Monitoring of the optional surge protection is also integrated. Up to 16
CMC III CAN-Bus sensors can be connected to monitor environmental parameters such as temperature, air humidity, or smoke. Connection is via a CAN-Bus interface (RJ45), with up to 6 RJ45 ports available for sensor units. Compatible accessories include CAN-Bus cables in various lengths, covers for C13 and C19 socket outlets, mounting adapters, universal locking mechanisms, numeric code locks, transponder readers, and online comfort handles.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT- or TS IT-racks. The delivery includes the
fastening material. The connection cable (CEE, 3 m) is connected directly to the feed. The PDU is designed for vertical mounting, with the display unit being rotatable and replaceable by 180° to ensure optimal operability.
Operational Advantages
The PDU offers a fully redundant Ethernet interface (10/100/1000 Mbit/s) and supports numerous protocols such as HTTP/HTTPS, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, FTP/SFTP. Integration into DCIM software is possible via MIB. User management with rights management, LDAP(S)/Radius/Active Directory integration, and Syslog server connection (up to 2 servers) enables centralized administration. Integrated email alarms (SMTP) and an additional relay output (changeover contact) for external alarm systems are provided. The operating temperature range is between 5 °C and 50 °C, with relative humidity (non-condensing) between 10 % and 95 %. The storage temperature range is -20 °C to 70 °C. The PDU complies with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21.