Rittal 7979216 PDU metered, 32A/230V, 1~, 24 x C13 + 4 x C19
|
668,96 EUR |
|
|
( 796,06 EUR incl. VAT ) ≈ £559.92 | ≈ $735.19 plus delivery charges: 100,00 € |
|
| Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline | |
| In Stock: 2 pieces | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 1910547 |
| Mfg Part No: | 7979216 |
| UPC/EAN: | 4028177947696 |
| Weight: | 5.36 kg |
| Type: | DK 7979216 |
Product information for Rittal 7979216:
Applications
The PDU is designed for use in VX IT type racks, particularly in cabinet frames or 48,3 cm ( 19 inch ) profile rails with a minimum length of 1,800 mm. When mounted vertically, it can be installed tool-free in the Zero-U-Space, minimizing rack space requirements. The colour-coded phase marking (L1=pink, L2=black, L3=white) and fuse circuits facilitate identification and maintenance. The PDU is self-powered, meaning it does not require an external power supply for its control and measurement functions.
Functions and Equipment in Detail
The PDU features a powerful CPU (ARM Cortex A8) and enables measurement of voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current. Measurement accuracy is ±1 % (kWh) according to EN 62053-21. A bright TFT display with 128x128 pixels (RGB) and backlighting shows performance data and basic configuration. The display is rotatable by 180° and replaceable, ensuring correct orientation when mounted vertically. Position sensors ensure correct display orientation on the web interface. An integrated electromagnetic buzzer enables acoustic alarm signaling. Operating hour counters for total and cycle operation are resettable. The PDU includes an integrated, fully redundant power supply that can be powered from all phases, ensuring fault-tolerant power supply.
Technology Explained Simply
The PDU is equipped with an integrated real-time clock buffered by a battery with a lifespan of up to 10 years (replaceable), enabling precise timestamping of measurements and events. The PDU supports setting of thresholds for voltage, current, and power, triggering warnings or alarm signals. A digital input (potential-free contact) and an additional alarm output (relay output, changeover) allow integration into external monitoring systems. The PDU is powered via the input, so no additional external power supply is required.
Compatibility and Accessories
The PDU is equipped with a variety of interfaces: A USB 2.0 port (USB-A) is used for mass configuration, firmware updates, and data logging. A CAN-Bus interface (RJ45) enables connection to up to 16 CMC III CAN-Bus sensors for environmental monitoring. A serial interface RS232 (RJ12) supports connection to an LTE unit, scripting, and CLI. The fully redundant Ethernet interface (10/100/1000 Mbit/s) enables communication via TCP/IP v4 and v6. The PDU supports protocols such as HTTP, HTTPS, SSL, SSH, Telnet, NTP, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, and FTP/SFTP. Integration into DCIM software is possible via MIB. Connection to LDAP(S), Radius, Active Directory, and Syslog servers (up to 2 servers) is also supported. Integrated email notification on alarm (SMTP) is available. The PDU includes an integrated monitoring system for optional surge protection Type 3, featuring replaceable surge arresters during operation and can be integrated into the PDU housing. Differential current measurement (Type B) per input, phase, or fuse is also possible. Other housing colours are available as optional.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of VX IT racks. The delivery includes mounting hardware for installation in VX IT racks. The PDU is designed for use in racks with a minimum length of 1,800 mm. The supply cable has a length of 3 m and is fitted with a CEE plug.
Operational Advantages
The PDU offers high measurement accuracy and comprehensive monitoring functions, which are important for energy efficiency and failure prediction in IT infrastructures. The integrated real-time clock and battery backup ensure reliable timestamping. The fully redundant power supply increases fault tolerance. Support for numerous protocols and interfaces enables flexible integration into existing network and monitoring systems. Tool-free mounting and compact design optimize rack space requirements. The PDU is designed for operating temperatures from 5 °C to 50 °C and humidity levels from 10 % to 95 % (non-condensing). The storage temperature range is -20 °C to 70 °C. The PDU complies with the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21.
| General | |
| Model | PDU, metered |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | Surge protection Type 3 with replaceable discharge devices during operation, with status monitoring, integrable into PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional surge protection, other housing colours available, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors |
| Description of measurement functions | measurement per phase or input, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact) |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.495 mm |
| Number of sockets and type | 24 x C13 / 4 x C19 |
| Rated operating voltage | 230 V (AC) |
| Rated current (max.) | 32 A |
| Nominal power | 7,4 kW |
| Power supplies | Number: 1, Phases per input: 1~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Number of RJ45 ports for sensor units max | 2 |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,800 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm |
Questions & answers
What is the delivery time of Rittal 7979216 PDU metered, 32A/230V, 1~, 24 x C13 + 4 x C19?
The article Rittal 7979216 PDU metered, 32A/230V, 1~, 24 x C13 + 4 x C19 is currently in stock
According to our experience the article is ready for dispatch within 12 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Rittal 7979216 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Rittal 7979216 PDU metered, 32A/230V, 1~, 24 x C13 + 4 x C19 always at the best possible price. We can give you a discount of 2% on Rittal 7979216 PDU metered, 32A/230V, 1~, 24 x C13 + 4 x C19 if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Rittal 7979216 PDU metered, 32A/230V, 1~, 24 x C13 + 4 x C19
|
Rittal 7030090 Monitoring system CMC III CAN-Bus cable RJ45 0.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360234 Mfg Part No: 7030090 Type: DK 7030090 |
8,40 EUR
![]() ≈ £7.03 | ≈ $9.23
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360235 Mfg Part No: 7030091 Type: DK 7030091 |
10,01 EUR
![]() ≈ £8.38 | ≈ $11.00
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030092 Monitoring system CMC III CAN-Bus cable RJ45 1.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360238 Mfg Part No: 7030092 Type: DK 7030092 |
-11% 11,62 EUR 13,05 EUR
![]() ≈ £9.73 | ≈ $12.77
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Rittal 7030093 Monitoring system CMC III CAN-Bus connection cable
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360246 Mfg Part No: 7030093 Type: DK 7030093 |
13,23 EUR
![]() ≈ £11.07 | ≈ $14.54
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955010 Coverings PDU socket strip C13 socket 10 pcs
The DK 7955010 from Rittal is a socket cover for IEC 60 320 C13 sockets, used in PDU socket strips (Power Distribution Units). The product is designed to securely close unused sockets, preventing ...Lieske Part No.: 981045 Mfg Part No: 7955010 Type: DK 7955010 |
132,03 EUR
![]() ≈ £110.51 | ≈ $145.10
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955015 Coverings PDU socket strip C19 socket 10 pcs
The DK 7955015 socket cover from Rittal is a special accessory designed for use with PDU socket strips (Power Distribution Units). It is intended for the secure closure of open, unused IEC 60 320 C19 ...Lieske Part No.: 981047 Mfg Part No: 7955015 Type: DK 7955015 |
-12% 9,51 EUR 10,82 EUR
![]() ≈ £7.96 | ≈ $10.45
Made to order · Delivery time approx. 5 workdaysinfo_outline
|
|
Rittal 7000688 Mounting adapter PDU TE 8000 2 pcs
The Rittal mounting adapter DK 7000688 is designed for securing a Power Distribution Unit (PDU) to a horizontal system chassis in the VX IT enclosure type. It is specifically designed for integrating ...Lieske Part No.: 999510 Mfg Part No: 7000688 Type: DK 7000688 |
12,88 EUR
![]() ≈ £10.78 | ≈ $14.16
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979020 PDU universal lock for C14/C20 plugs
The DK 7979020 is a plug lock from the manufacturer Rittal, specifically designed for secure fixation of IEC 60 320 C14 and C20 plugs in PDU- or PSM-modules equipped with C13/C19 sockets. This lock ...Lieske Part No.: 1101023 Mfg Part No: 7979020 Type: DK 7979020 |
26,80 EUR
![]() ≈ £22.43 | ≈ $29.45
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030223 Number code lock for CMC III
The Rittal DK 7030223 is a numeric code lock for access control on enclosure doors, specifically designed for use with the CMC III system. It enables secure and controlled access authorization to ...Lieske Part No.: 1775554 Mfg Part No: 7030223 Type: DK 7030223 |
203,92 EUR
![]() ≈ £170.68 | ≈ $224.11
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030233 VX IT CMC III transponder reader, RAL 9005
The Rittal IT 7030233 is a transponder reader for access control at doors, particularly at VX IT doors and side room doors. It is used for secure release of rack, room, or enclosure doors and is ...Lieske Part No.: 1775580 Mfg Part No: 7030233 Type: IT 7030233 |
337,80 EUR
![]() ≈ £282.74 | ≈ $371.24
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979722 PDU surge protection, rated power: 7.4 kW, rated voltage: 230 V,
The Rittal DK 7979722 is a surge protection module of Type 3 design, specifically developed for end-device protection in electrical installations. It serves as the final stage in the surge protection ...Lieske Part No.: 1775588 Mfg Part No: 7979722 Type: DK 7979722 |
-10% 158,70 EUR 176,10 EUR
![]() ≈ £132.83 | ≈ $174.41
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030611 CMC III online comfort handle VX with Master-Key function
The Rittal IT 7030611 is a CMC III Online comfort handle VX with Master-Key function, specifically developed for use on VX and VX IT enclosures. It provides secure door locking, monitoring of the ...Lieske Part No.: 1775710 Mfg Part No: 7030611 Type: IT 7030611 |
-12% 240,01 EUR 272,99 EUR
![]() ≈ £200.89 | ≈ $263.77
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|