Rittal 7979216, EAN: 4028177947696

Rittal 7979216 PDU metered 24x C13 4x C19

19 Inch-Technology > Accessories/Equipment > Energy Management

Rittal 7979216 PDU metered 24x C13 4x C19

Lieske Part No. 1910547
Mfg Part No 7979216
EAN-Code 4028177947696
Manufacturer Rittal
Here only 668,96 EUR
796,06 EUR incl. VAT

Further information for Rittal 7979216 PDU metered 24x C13 4x C19

General
ModelPDU, metered
MaterialAluminium profile, black anodised, mounting slots: plastic
Scope of deliveryIncluding mounting hardware
OptionsSurge protection Type 3 with replaceable discharge devices during operation, with status monitoring, integrable into PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional surge protection, other housing colours available, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors
Description of measurement functionsmeasurement per phase or input, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact)
Width44 mm
Depth70 mm
Length1.495 mm
Number of sockets and type24 x C13 / 4 x C19
Rated operating voltage230 V (AC)
Rated current (max.)32 A
Nominal power7,4 kW
Power suppliesNumber: 1, Phases per input: 1~
Connection cable length3 m
Electrical connection typeCEE
InterfacesUSB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s
Number of RJ45 ports for sensor units max2
PoliciesEMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU
StandardsEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21
ProtocolsWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer)
Operating temperature range5 °C...50 °C
Humidity (non-condensing)10...95 %
Storage temperature range-20 °C...70 °C
Suitable forHousing type: VX IT cabinet frame: ≥ 1,800 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm
The Rittal DK 7979216 is a PDU (Power Distribution Unit) with energy measurement and integrated network and control system, specifically designed for use in IT network and server racks. As a metered PDU, it enables precise measurement of power consumption per phase or at the input, allowing the energy demand of an entire rack to be monitored. The device is housed in a compact aluminium profile with a black anodized surface and has a length of 1,495 mm, a width of 44 mm, and a depth of 70 mm. Power distribution is provided via 24 C13 outlets and 4 C19 outlets, with the socket inserts made of plastic. The rated operating voltage is 230 V (AC), the maximum rated current is 32 A, corresponding to a rated power of 7.4 kW. Power input is via a CEE supply cable with a length of 3 m.

Applications
The PDU is designed for use in VX IT type racks, particularly in cabinet frames or 48,3 cm ( 19 inch ) profile rails with a minimum length of 1,800 mm. When mounted vertically, it can be installed tool-free in the Zero-U-Space, minimizing rack space requirements. The colour-coded phase marking (L1=pink, L2=black, L3=white) and fuse circuits facilitate identification and maintenance. The PDU is self-powered, meaning it does not require an external power supply for its control and measurement functions.

Functions and Equipment in Detail
The PDU features a powerful CPU (ARM Cortex A8) and enables measurement of voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current. Measurement accuracy is ±1 % (kWh) according to EN 62053-21. A bright TFT display with 128x128 pixels (RGB) and backlighting shows performance data and basic configuration. The display is rotatable by 180° and replaceable, ensuring correct orientation when mounted vertically. Position sensors ensure correct display orientation on the web interface. An integrated electromagnetic buzzer enables acoustic alarm signaling. Operating hour counters for total and cycle operation are resettable. The PDU includes an integrated, fully redundant power supply that can be powered from all phases, ensuring fault-tolerant power supply.

Technology Explained Simply
The PDU is equipped with an integrated real-time clock buffered by a battery with a lifespan of up to 10 years (replaceable), enabling precise timestamping of measurements and events. The PDU supports setting of thresholds for voltage, current, and power, triggering warnings or alarm signals. A digital input (potential-free contact) and an additional alarm output (relay output, changeover) allow integration into external monitoring systems. The PDU is powered via the input, so no additional external power supply is required.

Compatibility and Accessories
The PDU is equipped with a variety of interfaces: A USB 2.0 port (USB-A) is used for mass configuration, firmware updates, and data logging. A CAN-Bus interface (RJ45) enables connection to up to 16 CMC III CAN-Bus sensors for environmental monitoring. A serial interface RS232 (RJ12) supports connection to an LTE unit, scripting, and CLI. The fully redundant Ethernet interface (10/100/1000 Mbit/s) enables communication via TCP/IP v4 and v6. The PDU supports protocols such as HTTP, HTTPS, SSL, SSH, Telnet, NTP, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, and FTP/SFTP. Integration into DCIM software is possible via MIB. Connection to LDAP(S), Radius, Active Directory, and Syslog servers (up to 2 servers) is also supported. Integrated email notification on alarm (SMTP) is available. The PDU includes an integrated monitoring system for optional surge protection Type 3, featuring replaceable surge arresters during operation and can be integrated into the PDU housing. Differential current measurement (Type B) per input, phase, or fuse is also possible. Other housing colours are available as optional.

Mounting and Installation
Mounting is tool-free in the Zero-U-Space of VX IT racks. The delivery includes mounting hardware for installation in VX IT racks. The PDU is designed for use in racks with a minimum length of 1,800 mm. The supply cable has a length of 3 m and is fitted with a CEE plug.

Operational Advantages
The PDU offers high measurement accuracy and comprehensive monitoring functions, which are important for energy efficiency and failure prediction in IT infrastructures. The integrated real-time clock and battery backup ensure reliable timestamping. The fully redundant power supply increases fault tolerance. Support for numerous protocols and interfaces enables flexible integration into existing network and monitoring systems. Tool-free mounting and compact design optimize rack space requirements. The PDU is designed for operating temperatures from 5 °C to 50 °C and humidity levels from 10 % to 95 % (non-condensing). The storage temperature range is -20 °C to 70 °C. The PDU complies with the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1910547
qrcode für Rittal 7979216 PDU metered 24x C13 4x C19