Rittal 7979215 PDU Metered 16A/1P CEE 24xC13 / 4xC19
|
-9% 659,41 EUR 723,77 EUR |
|
|
( 784,70 EUR incl. VAT ) ≈ £551.93 | ≈ $724.69 plus delivery charges: 100,00 € |
|
| Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline | |
| In Stock: 2 pieces | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 1910546 |
| Mfg Part No: | 7979215 |
| UPC/EAN: | 4028177947689 |
| Weight: | 5.46 kg |
| Type: | DK 7979215 |
Product information for Rittal 7979215:
Applications
The PDU is designed for use in IT infrastructures, particularly in server racks, network, and data processing environments. It is suitable for power distribution and monitoring in racks with a minimum length of 1,800 mm, both in VX IT enclosure frames and VX IT 48,3 cm ( 19 inch ) profile rails. The integrated energy measurement per phase enables accurate monitoring of power consumption for individual IT systems or entire rack loads, which is relevant for energy efficiency analysis, load management, and data center infrastructure management (DCIM). The color coding of phases (L1=pink, L2=black, L3=white) supports phase assignment and error prevention during installation.
Functions and Equipment in Detail
The DK 7979215 features 24 C13 outlets and 4 C19 outlets, made of plastic and arranged on an aluminum profile with a black anodized finish. Measurement functions include voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current measurement for unbalanced load detection. Measurement accuracy is ±1 % (kWh) according to standard EN 62053-21. A bright TFT display with 128x128 pixels (RGB) and backlighting shows power data and basic configuration. The display is rotatable by 180° and replaceable, ensuring optimal readability during vertical mounting. An integrated electromagnetic buzzer provides acoustic alarm for exceeding set thresholds for voltage, current, or power. Operating hour counters are resettable both globally and cyclically.
Technology Explained Simply
The PDU is equipped with a powerful CPU (ARM Cortex A8) ensuring data processing and communication. Power supply is via an integrated, fully redundant power supply unit, which can be powered from all phases, ensuring fault-tolerant and reliable operation. The PDU is self-powered and does not require external power supply. The integrated real-time clock is buffered by a replaceable battery with a lifespan of up to 10 years, ensuring time accuracy even during power failure. Measurement is performed per phase or per input, enabling detailed load analysis.
Compatibility and Accessories
The PDU is equipped with a variety of interfaces enabling flexible integration into existing IT infrastructures. These include a fully redundant Ethernet interface (10/100/1000 Mbit/s), a CAN-Bus interface (RJ45) for connecting up to 16 CMC III environmental sensors, an RS232 interface (RJ12) for LTE modules, scripting, and CLI, as well as a USB 2.0 port (USB-A) for mass configuration, firmware updates, and data logging. Communication occurs via protocols such as HTTP/HTTPS, SSH, Telnet, SNMP v1/v2c/v3, Modbus/TCP, OPC-UA, FTP/SFTP, NTP, TCP/IP v4 & v6, DHCP, DNS, and MIB, enabling integration into DCIM software and other monitoring systems. Additionally, the PDU supports connection to LDAP(S), Radius, Active Directory, and Syslog servers (up to 2 servers). Optionally, a Type 3 surge protection device with replaceable discharge elements during operation can be integrated, with status monitoring. Differential current measurement (Type B) per input/phase/fuse is also possible. The PDU includes a digital input (potential-free contact) and an additional relay output (changeover contact) to process external signals and trigger alarms.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes necessary mounting hardware. Vertical mounting enables optimal space utilization in the rack. The 3 m long power cord allows flexible positioning of the input. The PDU is designed for an operating temperature of 5 °C to 50 °C and humidity of 10 % to 95 % (non-condensing). Storage temperature is -20 °C to 70 °C.
Operational Advantages
The DK 7979215 offers high operational reliability through redundant power supply and integrated alarm functions. Precise energy measurement enables detailed load analysis and optimization of energy consumption. Support for various protocols and interfaces simplifies integration into existing IT monitoring systems. Tool-free mounting and compact design reduce installation time. The integrated real-time clock with battery backup ensures continuous time measurement even during power failure. The PDU is compliant with IT infrastructure standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, as well as the EMC Directive 2014/30/EU and the Low Voltage Directive 2014/35/EU.
| General | |
| Model | PDU, metered |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | Overvoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available |
| Description of measurement functions | measurement per phase or input, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact) |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.295 mm |
| Number of sockets and type | 24 x C13 / 4 x C19 |
| Rated operating voltage | 230 V (AC) |
| Rated current (max.) | 16 A |
| Nominal power | 3,7 kW |
| Power supplies | Number: 1, Phases per input: 1~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,800 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm |
Questions & answers
What is the delivery time of Rittal 7979215 PDU Metered 16A/1P CEE 24xC13 / 4xC19?
The article Rittal 7979215 PDU Metered 16A/1P CEE 24xC13 / 4xC19 is currently in stock
According to our experience the article is ready for dispatch within 12 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Rittal 7979215 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Rittal 7979215 PDU Metered 16A/1P CEE 24xC13 / 4xC19 always at the best possible price. We can give you a discount of 2% on Rittal 7979215 PDU Metered 16A/1P CEE 24xC13 / 4xC19 if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Rittal 7979215 PDU Metered 16A/1P CEE 24xC13 / 4xC19
|
Rittal 7030090 Monitoring system CMC III CAN-Bus cable RJ45 0.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360234 Mfg Part No: 7030090 Type: DK 7030090 |
8,40 EUR
![]() ≈ £7.03 | ≈ $9.23
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360235 Mfg Part No: 7030091 Type: DK 7030091 |
10,01 EUR
![]() ≈ £8.38 | ≈ $11.00
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030092 Monitoring system CMC III CAN-Bus cable RJ45 1.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360238 Mfg Part No: 7030092 Type: DK 7030092 |
-11% 11,62 EUR 13,05 EUR
![]() ≈ £9.73 | ≈ $12.77
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Rittal 7030093 Monitoring system CMC III CAN-Bus connection cable
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360246 Mfg Part No: 7030093 Type: DK 7030093 |
13,23 EUR
![]() ≈ £11.07 | ≈ $14.54
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955010 Coverings PDU socket strip C13 socket 10 pcs
The DK 7955010 from Rittal is a socket cover for IEC 60 320 C13 sockets, used in PDU socket strips (Power Distribution Units). The product is designed to securely close unused sockets, preventing ...Lieske Part No.: 981045 Mfg Part No: 7955010 Type: DK 7955010 |
132,03 EUR
![]() ≈ £110.51 | ≈ $145.10
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955015 Coverings PDU socket strip C19 socket 10 pcs
The DK 7955015 socket cover from Rittal is a special accessory designed for use with PDU socket strips (Power Distribution Units). It is intended for the secure closure of open, unused IEC 60 320 C19 ...Lieske Part No.: 981047 Mfg Part No: 7955015 Type: DK 7955015 |
-12% 9,51 EUR 10,82 EUR
![]() ≈ £7.96 | ≈ $10.45
Made to order · Delivery time approx. 5 workdaysinfo_outline
|
|
Rittal 7000688 Mounting adapter PDU TE 8000 2 pcs
The Rittal mounting adapter DK 7000688 is designed for securing a Power Distribution Unit (PDU) to a horizontal system chassis in the VX IT enclosure type. It is specifically designed for integrating ...Lieske Part No.: 999510 Mfg Part No: 7000688 Type: DK 7000688 |
12,88 EUR
![]() ≈ £10.78 | ≈ $14.16
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979020 PDU universal lock for C14/C20 plugs
The DK 7979020 is a plug lock from the manufacturer Rittal, specifically designed for secure fixation of IEC 60 320 C14 and C20 plugs in PDU- or PSM-modules equipped with C13/C19 sockets. This lock ...Lieske Part No.: 1101023 Mfg Part No: 7979020 Type: DK 7979020 |
26,80 EUR
![]() ≈ £22.43 | ≈ $29.45
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979711 RCM measuring module 48,3 cm ( 19 inch ) inline meter 16A/1P CEE input and output
The Rittal DK 7979711 is an autonomous energy monitoring module in the 1 HE/48,3 cm ( 19 inch ) form factor, specifically developed for integration into existing power supply systems. It serves as an ...Lieske Part No.: 1101086 Mfg Part No: 7979711 Type: DK 7979711 |
-10% 983,25 EUR 1.086,84 EUR
![]() ≈ £822.98 | ≈ $1,080.59
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Rittal 7030223 Number code lock for CMC III
The Rittal DK 7030223 is a numeric code lock for access control on enclosure doors, specifically designed for use with the CMC III system. It enables secure and controlled access authorization to ...Lieske Part No.: 1775554 Mfg Part No: 7030223 Type: DK 7030223 |
203,92 EUR
![]() ≈ £170.68 | ≈ $224.11
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030233 VX IT CMC III transponder reader, RAL 9005
The Rittal IT 7030233 is a transponder reader for access control at doors, particularly at VX IT doors and side room doors. It is used for secure release of rack, room, or enclosure doors and is ...Lieske Part No.: 1775580 Mfg Part No: 7030233 Type: IT 7030233 |
337,80 EUR
![]() ≈ £282.74 | ≈ $371.24
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979721 Surge protection module Type 3
The Rittal DK 7979721 is an overvoltage protection module of Type 3, specifically designed for end-device protection in 19-inch technology and enclosures. It serves as the final stage in the ...Lieske Part No.: 1775589 Mfg Part No: 7979721 Type: DK 7979721 |
155,83 EUR
![]() ≈ £130.43 | ≈ $171.26
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030611 CMC III online comfort handle VX with Master-Key function
The Rittal IT 7030611 is a CMC III Online comfort handle VX with Master-Key function, specifically developed for use on VX and VX IT enclosures. It provides secure door locking, monitoring of the ...Lieske Part No.: 1775710 Mfg Part No: 7030611 Type: IT 7030611 |
-12% 240,01 EUR 272,99 EUR
![]() ≈ £200.89 | ≈ $263.77
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|