Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English
Rittal Logo

Rittal 7979511 DK PDU metered+ basic power distribution BLT44x1095x70 CEE7/

Your rating:
Average rating
product review for Rittal 7979511 DK PDU metered+ basic power distribution BLT44x1095x70 CEE7/
( 0 / 5 ) 0 ratings
Rittal 7979511
This image may differ from the desired article.
Rittal 7979511Rittal 7979511Rittal 7979511Rittal 7979511Rittal 7979511Rittal 7979511Rittal 7979511
1.213,94 EUR 1.270,20 EUR
( 1.444,59 EUR incl. VAT )
≈ £1,016.07  |  ≈ $1,334.12
plus delivery charges: 55,00 €
Made to order · Delivery time approx. 5 workdaysinfo_outline
1x Rittal 7979511 DK PDU metered+ basic power distribution BLT44x1095x70 CEE7/
Datasheet:file_download Download
Lieske Part No.:1867237
Mfg Part No: 7979511
UPC/EAN: 4028177948303
Weight:0.123 kg
Type:DK 7979511

Product information for Rittal 7979511:

The Rittal DK 7979511 is a PDU (Power Distribution Unit) of the metered plus type, designed as an intelligent power distribution unit for IT network and server racks. The device enables precise energy measurement per individual outlet socket, allowing the power demand of individual consumers to be monitored. The unit is housed in a compact aluminium profile housing with a black anodized surface and features 10 Schuko sockets (Type F, CEE 7/3). The rated operating voltage is 230 V (AC), with a maximum rated current of 16 A, corresponding to a rated power of 3.7 kW. Power supply is via a CEE connection cable with a length of 3 m. The PDU is self-powered and does not require external power supply. The integrated real-time clock is buffered by a replaceable battery with a lifespan of up to 10 years. Measurement accuracy is ±1 % (kWh) in accordance with standard EN 62053-21.

Applications

The PDU is designed for use in IT infrastructures, particularly in racks of the Rittal VX IT type. When mounted vertically, it can be installed tool-free in the Zero-U-Space of VX IT or TS IT racks. The unit is suitable for enclosure types with a cabinet frame of at least 1,200 mm or 48,3 cm ( 19 inch ) profile rails of at least 1,800 mm. The phase colour coding (L1=pink, L2=black, L3=white) facilitates identification and maintenance. The PDU is designed for indoor use, with an operating temperature range of 5 °C to 50 °C and humidity of 10 % to 95 % (non-condensing).

Functions and Equipment in Detail

The PDU features a bright TFT display with 128x128 pixels (RGB) and backlighting, showing performance data and basic configuration. The display is rotatable by 180° and replaceable, ensuring correct display orientation when mounted vertically. Multicoloured LEDs (green/yellow/red) indicate the switching state and threshold values per outlet socket. An integrated electromagnetic buzzer enables acoustic alarm signalling. Voltage, current, and power thresholds can be individually set per outlet socket. The PDU offers an integrated, fully redundant power supply, which can be powered from all phases, ensuring fault-tolerant operation.

Technology Explained Simply

The PDU is equipped with a powerful CPU (ARM Cortex A8) that handles measurement and control functions. Measurement functions include voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current measurement for unbalanced load detection. For PDUs with integrated fuses, fuse monitoring is performed. The PDU features a digital input (potential-free contact) and an additional alarm output/relay output (changeover) for external signals. Power supply is via an integrated, fully redundant power supply unit, which can be powered from all phases.

Compatibility and Accessories

The PDU is expandable with a variety of options. These include a Type 3 surge protection device with replaceable discharge elements during operation, which can be integrated into the housing, as well as residual current measurement (Type B) per input/phase/fuse. Monitoring of the optional surge protection device is also possible. The PDU supports connection of CMC III CAN-Bus sensors for environmental monitoring, with up to 16 sensors connectable. Suitable accessories include, among others, combination locks, CAN-Bus connection cables, covers for socket strips, mounting adapters, and the CMC III Online comfort handle VX with master key function.

Mounting and Installation

Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes the necessary mounting material. Vertical mounting is standard, with the display rotatable by 180° to ensure correct display. The PDU is designed for use in racks with a minimum length of 1,200 mm (cabinet frame) or 1,800 mm (48,3 cm ( 19 inch ) profile rails).

Operational Advantages

The PDU offers high measurement accuracy and enables detailed energy measurement per outlet socket, which is beneficial for energy efficiency and load distribution in data centres. The integrated real-time clock with battery backup ensures continuous time measurement even during power failure. The fully redundant power supply increases reliability. Network interfaces enable remote monitoring and control, allowing the PDU to be integrated into existing DCIM systems. The use of protocols such as SNMP, Modbus/TCP, OPC-UA, and MIB facilitates integration into third-party systems. The PDU also supports email alerts on alarm (SMTP), user management with rights management, and integration with LDAP(S), Radius, or Active Directory. The serial interface RS232 (RJ12) enables use for LTE units, scripting, and CLI. The USB 2.0 interface (USB-A) is used for mass configuration, firmware updates, and data logging. The CAN-Bus interface (RJ45) enables connection of up to 16 environmental sensors. The PDU is designed for indoor use, with an operating temperature range of 5 °C to 50 °C and humidity of 10 % to 95 % (non-condensing). The storage temperature range is -20 °C to 70 °C. The PDU complies with the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21. Protocols include web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into third-party DCIM software, and FTP/SFTP (update/file transfer). The PDU is designed for use in IT infrastructures, particularly in racks of the Rittal VX IT type. When mounted vertically, it can be installed tool-free in the Zero-U-Space of VX IT or TS IT racks. The unit is suitable for enclosure types with a cabinet frame of at least 1,200 mm or 48,3 cm ( 19 inch ) profile rails of at least 1,800 mm. The phase colour coding (L1=pink, L2=black, L3=white) facilitates identification and maintenance. The PDU is designed for indoor use, with an operating temperature range of 5 °C to 50 °C and humidity of 10 % to 95 % (non-condensing). The PDU features a bright TFT display with 128x128 pixels (RGB) and backlighting, showing performance data and basic configuration. The display is rotatable by 180° and replaceable, ensuring correct display orientation when mounted vertically. Multicoloured LEDs (green/yellow/red) indicate the switching state and threshold values per outlet socket. An integrated electromagnetic buzzer enables acoustic alarm signalling. Voltage, current, and power thresholds can be individually set per outlet socket. The PDU offers an integrated, fully redundant power supply, which can be powered from all phases, ensuring fault-tolerant operation. The PDU is equipped with a powerful CPU (ARM Cortex A8) that handles measurement and control functions. Measurement functions include voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current measurement for unbalanced load detection. For PDUs with integrated fuses, fuse monitoring is performed. The PDU features a digital input (potential-free contact) and an additional alarm output/relay output (changeover) for external signals. Power supply is via an integrated, fully redundant power supply unit, which can be powered from all phases. The PDU is expandable with a variety of options. These include a Type 3 surge protection device with replaceable discharge elements during operation, which can be integrated into the housing, as well as residual current measurement (Type B) per input/phase/fuse. Monitoring of the optional surge protection device is also possible. The PDU supports connection of CMC III CAN-Bus sensors for environmental monitoring, with up to 16 sensors connectable. Suitable accessories include, among others, combination locks, CAN-Bus connection cables, covers for socket strips, mounting adapters, and the CMC III Online comfort handle VX with master key function. Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes the necessary mounting material. Vertical mounting is standard, with the display rotatable by 180° to ensure correct display. The PDU is designed for use in racks with a minimum length of 1,200 mm (cabinet frame) or 1,800 mm (48,3 cm ( 19 inch ) profile rails). The PDU offers high measurement accuracy and enables detailed energy measurement per outlet socket, which is beneficial for energy efficiency and load distribution in data centres. The integrated real-time clock with battery backup ensures continuous time measurement even during power failure. The fully redundant power supply increases reliability. Network interfaces enable remote monitoring and control, allowing the PDU to be integrated into existing DCIM systems. The use of protocols such as SNMP, Modbus/TCP, OPC-UA, and MIB facilitates integration into third-party systems. The PDU also supports email alerts on alarm (SMTP), user management with rights management, and integration with LDAP(S), Radius, or Active Directory. The serial interface RS232 (RJ12) enables use for LTE units, scripting, and CLI. The USB 2.0 interface (USB-A) is used for mass configuration, firmware updates, and data logging. The CAN-Bus interface (RJ45) enables connection of up to 16 environmental sensors. The PDU is designed for indoor use, with an operating temperature range of 5 °C to 50 °C and humidity of 10 % to 95 % (non-condensing). The storage temperature range is -20 °C to 70 °C. The PDU complies with the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21. Protocols include web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into third-party DCIM software, and FTP/SFTP (update/file transfer).

General
ModelPDU, metered plus
MaterialAluminium profile, black anodised, mounting slots: plastic
Scope of deliveryIncluding mounting hardware
OptionsOvervoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available
Description of measurement functionsMeasurement per phase or input, additional measurement per output socket, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact)
Width44 mm
Depth70 mm
Length1.095 mm
Number of sockets and type10 x Schuko (Type F, CEE 7/3)
Socket outlets10 x Schuko
Rated operating voltage230 V (AC)
Rated current (max.)16 A
Nominal power3,7 kW
Power suppliesNumber: 1, Phases per input: 1~
Connection cable length3 m
Electrical connection typeCEE
InterfacesUSB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s
PoliciesEMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU
StandardsEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21
ProtocolsWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer)
Operating temperature range5 °C...50 °C
Humidity (non-condensing)10...95 %
Storage temperature range-20 °C...70 °C
Suitable forHousing type: VX IT cabinet frame: ≥ 1,200 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm


Product data sheet
Datasheet for Rittal 7979511, EAN: 4028177948303

Questions & answers

What is the delivery time of Rittal 7979511 DK PDU metered+ basic power distribution BLT44x1095x70 CEE7/?

The article Rittal 7979511 DK PDU metered+ basic power distribution BLT44x1095x70 CEE7/ is currently not in stock and must be ordered on a per-order basis.

According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Rittal 7979511 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Rittal 7979511 DK PDU metered+ basic power distribution BLT44x1095x70 CEE7/ always at the best possible price. We can give you a discount of 2% on Rittal 7979511 DK PDU metered+ basic power distribution BLT44x1095x70 CEE7/ if you choose payment in advance on ordering.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Fitting accessory for Rittal 7979511 DK PDU metered+ basic power distribution BLT44x1095x70 CEE7/

Rittal 7030090 Monitoring system CMC III CAN-Bus cable RJ45 0.5 m Rittal LogoRittal 7030090 Monitoring system CMC III CAN-Bus cable RJ45 0.5 m This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.
Applications: For connecting the CAN bus units.
Information and power ...

Lieske Part No.: 360234
Mfg Part No: 7030090
Type: DK 7030090
8,40 EUR
Rittal 7030090 plus VAT
≈ £7.03  |  ≈ $9.23
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m Rittal LogoRittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.
Applications: For connecting the CAN bus units.
Information and power ...

Lieske Part No.: 360235
Mfg Part No: 7030091
Type: DK 7030091
10,01 EUR
Rittal 7030091 plus VAT
≈ £8.38  |  ≈ $11.00
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7030092 Monitoring system CMC III CAN-Bus cable RJ45 1.5 m Rittal LogoRittal 7030092 Monitoring system CMC III CAN-Bus cable RJ45 1.5 m This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.
Applications: For connecting the CAN bus units.
Information and power ...

Lieske Part No.: 360238
Mfg Part No: 7030092
Type: DK 7030092
-11% 11,62 EUR 13,05 EUR
Rittal 7030092 plus VAT
≈ £9.73  |  ≈ $12.77
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
Rittal 7030093 Monitoring system CMC III CAN-Bus connection cable Rittal LogoRittal 7030093 Monitoring system CMC III CAN-Bus connection cable This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.
Applications: For connecting the CAN bus units.
Information and power ...

Lieske Part No.: 360246
Mfg Part No: 7030093
Type: DK 7030093
13,23 EUR
Rittal 7030093 plus VAT
≈ £11.07  |  ≈ $14.54
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7955010 Coverings PDU socket strip C13 socket 10 pcs Rittal LogoRittal 7955010 Coverings PDU socket strip C13 socket 10 pcs The DK 7955010 from Rittal is a socket cover for IEC 60 320 C13 sockets, used in PDU socket strips (Power Distribution Units). The product is designed to securely close unused sockets, preventing ...

Lieske Part No.: 981045
Mfg Part No: 7955010
Type: DK 7955010
132,03 EUR
Rittal 7955010 plus VAT
≈ £110.51  |  ≈ $145.10
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7955015 Coverings PDU socket strip C19 socket 10 pcs Rittal LogoRittal 7955015 Coverings PDU socket strip C19 socket 10 pcs The DK 7955015 socket cover from Rittal is a special accessory designed for use with PDU socket strips (Power Distribution Units). It is intended for the secure closure of open, unused IEC 60 320 C19 ...

Lieske Part No.: 981047
Mfg Part No: 7955015
Type: DK 7955015
-12% 9,51 EUR 10,82 EUR
Rittal 7955015 plus VAT
≈ £7.96  |  ≈ $10.45
Made to order · Delivery time approx. 5 workdaysinfo_outline
Rittal 7000688 Mounting adapter PDU TE 8000 2 pcs Rittal LogoRittal 7000688 Mounting adapter PDU TE 8000 2 pcs The Rittal mounting adapter DK 7000688 is designed for securing a Power Distribution Unit (PDU) to a horizontal system chassis in the VX IT enclosure type. It is specifically designed for integrating ...

Lieske Part No.: 999510
Mfg Part No: 7000688
Type: DK 7000688
12,88 EUR
Rittal 7000688 plus VAT
≈ £10.78  |  ≈ $14.16
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7979020 PDU universal lock for C14/C20 plugs Rittal LogoRittal 7979020 PDU universal lock for C14/C20 plugs The DK 7979020 is a plug lock from the manufacturer Rittal, specifically designed for secure fixation of IEC 60 320 C14 and C20 plugs in PDU- or PSM-modules equipped with C13/C19 sockets. This lock ...

Lieske Part No.: 1101023
Mfg Part No: 7979020
Type: DK 7979020
26,80 EUR
Rittal 7979020 plus VAT
≈ £22.43  |  ≈ $29.45
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7979711 RCM measuring module 48,3 cm ( 19 inch ) inline meter 16A/1P CEE input and output Rittal LogoRittal 7979711 RCM measuring module 48,3 cm ( 19 inch ) inline meter 16A/1P CEE input and output The Rittal DK 7979711 is an autonomous energy monitoring module in the 1 HE/48,3 cm ( 19 inch ) form factor, specifically developed for integration into existing power supply systems. It serves as an ...

Lieske Part No.: 1101086
Mfg Part No: 7979711
Type: DK 7979711
-10% 983,25 EUR 1.086,84 EUR
Rittal 7979711 plus VAT
≈ £822.98  |  ≈ $1,080.59
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
Rittal 7030223 Number code lock for CMC III Rittal LogoRittal 7030223 Number code lock for CMC III The Rittal DK 7030223 is a numeric code lock for access control on enclosure doors, specifically designed for use with the CMC III system. It enables secure and controlled access authorization to ...

Lieske Part No.: 1775554
Mfg Part No: 7030223
Type: DK 7030223
203,92 EUR
Rittal 7030223 plus VAT
≈ £170.68  |  ≈ $224.11
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7030233 VX IT CMC III transponder reader, RAL 9005 Rittal LogoRittal 7030233 VX IT CMC III transponder reader, RAL 9005 The Rittal IT 7030233 is a transponder reader for access control at doors, particularly at VX IT doors and side room doors. It is used for secure release of rack, room, or enclosure doors and is ...

Lieske Part No.: 1775580
Mfg Part No: 7030233
Type: IT 7030233
337,80 EUR
Rittal 7030233 plus VAT
≈ £282.74  |  ≈ $371.24
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7979721 Surge protection module Type 3 Rittal LogoRittal 7979721 Surge protection module Type 3 The Rittal DK 7979721 is an overvoltage protection module of Type 3, specifically designed for end-device protection in 19-inch technology and enclosures. It serves as the final stage in the ...

Lieske Part No.: 1775589
Mfg Part No: 7979721
Type: DK 7979721
155,83 EUR
Rittal 7979721 plus VAT
≈ £130.43  |  ≈ $171.26
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7030611 CMC III online comfort handle VX with Master-Key function Rittal LogoRittal 7030611 CMC III online comfort handle VX with Master-Key function The Rittal IT 7030611 is a CMC III Online comfort handle VX with Master-Key function, specifically developed for use on VX and VX IT enclosures. It provides secure door locking, monitoring of the ...

Lieske Part No.: 1775710
Mfg Part No: 7030611
Type: IT 7030611
-12% 240,01 EUR 272,99 EUR
Rittal 7030611 plus VAT
≈ £200.89  |  ≈ $263.77
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Rittal 7979511 PDU metered+ basic power distribution BLT44x1095x70 CEE7/
Rittal 7979511 DK PDU metered+ basic power distribution BLT44x1095x70 CEE7/
1.213,94 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Rittal 7979511 PDU metered+ basic power distribution BLT44x1095x70 CEE7/
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
1 + 6 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.