Rittal 7979442 PDU managed 16A/3P CEE 42xC13
|
-10% 2.014,80 EUR 2.228,54 EUR |
|
|
( 2.397,61 EUR incl. VAT ) ≈ £1,686.39 | ≈ $2,214.27 plus delivery charges: 55,00 € |
|
| Made to order · Delivery time approx. 5 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 1101077 |
| Mfg Part No: | 7979442 |
| UPC/EAN: | 4028177948259 |
| Weight: | 0.001 kg |
| Type: | DK 7979442 |
Product information for Rittal 7979442:
Applications
The PDU is designed for use in data centers, server rooms, and IT infrastructures where precise energy management, load monitoring, and remote control are required. It enables central control and monitoring of power consumption, voltage, current, and power per socket. The integrated real-time clock with battery backup (max. 10 years, replaceable) ensures continuity of time data even during power failure. The PDU is designed for an operating temperature of 5 °C to 50 °C and humidity of 10 % to 95 % (non-condensing).
Functions and Equipment in Detail
The PDU features 42 sockets of type C13 (IEC 60320), each of which can be individually monitored and controlled. The rated operating voltage is 400 V (AC), the maximum rated current is 16 A, corresponding to a rated power of 11 kW. Power input is via a CEE plug with a 3 m long supply cable. The PDU is self-powered, without external power supply. Measurement accuracy is ±1 % (kWh) according to standard EN 62053-21.
The sockets are color-coded: L1 (pink), L2 (black), L3 (white), to visually distinguish phases and fuse circuits. The integrated control unit with a bright TFT display (128x128 pixels, RGB, with backlight) shows performance data and basic configuration. The display is rotatable by 180° and replaceable. Multicolored LEDs (green/yellow/red) indicate the switching status and thresholds per socket. An integrated electromagnetic buzzer provides acoustic alarm.
Technology Explained Simply
The PDU is equipped with a powerful CPU (ARM Cortex A8) enabling processing of measurement data and control of functions. The PDU is redundantly powered across all phases, ensuring fault-tolerant operation. The relays are bistable, allowing low power consumption and high switching capacity even at high inrush currents (up to max. 300 A). Switching functions include programmable on/off behavior after voltage recovery (on/off/last status) and programmable switching behavior (time/programmable logic). Relay states are stored even during power failure.
Compatibility and Accessories
The PDU is equipped with a variety of interfaces: a fully redundant Ethernet interface (10/100/1000 Mbit/s), a USB 2.0 port (USB-A) for mass configuration, firmware updates, and data logging, a CAN-Bus interface (RJ45) for up to 16 environmental sensors of type CMC III, and a serial interface RS232 (RJ12) for LTE unit, scripting, and CLI. Communication occurs via protocols such as HTTP/HTTPS, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, and FTP/SFTP. Integration into DCIM software is possible via MIB.
Additionally, optional features include surge protection Type 3 with replaceable discharge elements during operation and status monitoring, differential current measurement (Type B) per input/phase/fuse, and monitoring of optional surge protection. Connection to LDAP(S), Radius, or Active Directory, as well as to Syslog servers (max. 2 servers), is possible. E-mail alarms can be sent via SMTP.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of VX IT or TS IT racks. The delivery includes the required mounting material. The PDU is designed for vertical mounting and can be installed in racks with a minimum length of 1,800 mm (cabinet frame) or 2,000 mm (48,3 cm ( 19 inch ) profile rails). Dimensions are 44 mm (width) × 1,695 mm (length) × 70 mm (depth).
Operational Advantages
The PDU enables precise energy management with individual control and monitoring per socket. The integrated real-time clock and storage of relay states ensure reliable operational continuity. Redundant power supply and bistable relays increase operational safety. Support for protocols such as SNMP, Modbus/TCP, and OPC-UA facilitates integration into existing monitoring and management systems. The ability to set individual thresholds for voltage, current, and power per socket enables flexible and safe use.
The PDU complies with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU. Standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21 are met. The PDU is suitable for use in IT infrastructures with high requirements for reliability and energy efficiency.
Batteries are not included in the delivery scope.
| General | |
| Model | PDU, managed |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | Overvoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.695 mm |
| Number of sockets and type | 42 x C13 |
| Socket outlets | 42 x C 13 |
| Rated operating voltage | 400 V (AC) |
| Rated current (max.) | 16 A |
| Nominal power | 11 kW |
| Power supplies | Number: 1, phases per input: 3~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,800 mm, housing type: VX IT 19"-profile rails: ≥ 2,000 mm |
Questions & answers
What is the delivery time of Rittal 7979442 PDU managed 16A/3P CEE 42xC13?
The article Rittal 7979442 PDU managed 16A/3P CEE 42xC13 is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Rittal 7979442 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Rittal 7979442 PDU managed 16A/3P CEE 42xC13 always at the best possible price. We can give you a discount of 2% on Rittal 7979442 PDU managed 16A/3P CEE 42xC13 if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Rittal 7979442 PDU managed 16A/3P CEE 42xC13
|
Rittal 7030090 Monitoring system CMC III CAN-Bus cable RJ45 0.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360234 Mfg Part No: 7030090 Type: DK 7030090 |
8,40 EUR
![]() ≈ £7.03 | ≈ $9.23
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360235 Mfg Part No: 7030091 Type: DK 7030091 |
10,01 EUR
![]() ≈ £8.38 | ≈ $11.00
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030092 Monitoring system CMC III CAN-Bus cable RJ45 1.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360238 Mfg Part No: 7030092 Type: DK 7030092 |
-11% 11,62 EUR 13,05 EUR
![]() ≈ £9.73 | ≈ $12.77
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Rittal 7030093 Monitoring system CMC III CAN-Bus connection cable
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360246 Mfg Part No: 7030093 Type: DK 7030093 |
13,23 EUR
![]() ≈ £11.07 | ≈ $14.54
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955010 Coverings PDU socket strip C13 socket 10 pcs
The DK 7955010 from Rittal is a socket cover for IEC 60 320 C13 sockets, used in PDU socket strips (Power Distribution Units). The product is designed to securely close unused sockets, preventing ...Lieske Part No.: 981045 Mfg Part No: 7955010 Type: DK 7955010 |
132,03 EUR
![]() ≈ £110.51 | ≈ $145.10
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955015 Coverings PDU socket strip C19 socket 10 pcs
The DK 7955015 socket cover from Rittal is a special accessory designed for use with PDU socket strips (Power Distribution Units). It is intended for the secure closure of open, unused IEC 60 320 C19 ...Lieske Part No.: 981047 Mfg Part No: 7955015 Type: DK 7955015 |
-12% 9,51 EUR 10,82 EUR
![]() ≈ £7.96 | ≈ $10.45
Made to order · Delivery time approx. 5 workdaysinfo_outline
|
|
Rittal 7000688 Mounting adapter PDU TE 8000 2 pcs
The Rittal mounting adapter DK 7000688 is designed for securing a Power Distribution Unit (PDU) to a horizontal system chassis in the VX IT enclosure type. It is specifically designed for integrating ...Lieske Part No.: 999510 Mfg Part No: 7000688 Type: DK 7000688 |
12,88 EUR
![]() ≈ £10.78 | ≈ $14.16
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979020 PDU universal lock for C14/C20 plugs
The DK 7979020 is a plug lock from the manufacturer Rittal, specifically designed for secure fixation of IEC 60 320 C14 and C20 plugs in PDU- or PSM-modules equipped with C13/C19 sockets. This lock ...Lieske Part No.: 1101023 Mfg Part No: 7979020 Type: DK 7979020 |
26,80 EUR
![]() ≈ £22.43 | ≈ $29.45
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030223 Number code lock for CMC III
The Rittal DK 7030223 is a numeric code lock for access control on enclosure doors, specifically designed for use with the CMC III system. It enables secure and controlled access authorization to ...Lieske Part No.: 1775554 Mfg Part No: 7030223 Type: DK 7030223 |
203,92 EUR
![]() ≈ £170.68 | ≈ $224.11
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030233 VX IT CMC III transponder reader, RAL 9005
The Rittal IT 7030233 is a transponder reader for access control at doors, particularly at VX IT doors and side room doors. It is used for secure release of rack, room, or enclosure doors and is ...Lieske Part No.: 1775580 Mfg Part No: 7030233 Type: IT 7030233 |
337,80 EUR
![]() ≈ £282.74 | ≈ $371.24
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979723 PDU surge protection, rated power: 11 kW, rated current: 50 A,
The Rittal DK 7979723 is an overvoltage protection module of type 3, specifically designed for end-device protection in electrical installations. It serves as the final stage in the overvoltage ...Lieske Part No.: 1775587 Mfg Part No: 7979723 Type: DK 7979723 |
218,73 EUR
![]() ≈ £183.08 | ≈ $240.38
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030611 CMC III online comfort handle VX with Master-Key function
The Rittal IT 7030611 is a CMC III Online comfort handle VX with Master-Key function, specifically developed for use on VX and VX IT enclosures. It provides secure door locking, monitoring of the ...Lieske Part No.: 1775710 Mfg Part No: 7030611 Type: IT 7030611 |
-12% 240,01 EUR 272,99 EUR
![]() ≈ £200.89 | ≈ $263.77
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979713 PDU RCM 48,3 cm ( 19 inch )-Inline Meter, 3-phase, rated power: 1
The Rittal DK 7979713 is an Inline Meter, an autonomous energy monitoring unit in the 1 HE/48,3 cm ( 19 inch ) form factor, which is inserted into the supply line of a consumer, a PDU basic, or a ...Lieske Part No.: 1989426 Mfg Part No: 7979713 Type: DK 7979713 |
1.040,06 EUR
![]() ≈ £870.53 | ≈ $1,143.03
Delivery time from supplier's stock (ca.) 6 workdaysinfo_outline
|