1.651,75 EUR 1.722,42 EUR |
|
|
( 1.965,58 EUR incl. VAT ) ≈ £1,382.51 | ≈ $1,815.27 plus delivery charges: 55,00 € |
|
| Made to order · Delivery time approx. 5 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 894143 |
| Mfg Part No: | 7979345 |
| UPC/EAN: | 4069196015119 |
| Weight: | 0.123 kg |
| Type: | DK 7979345 |
Product information for Rittal 7979345:
Applications
The PDU is specifically designed for use in IT infrastructures, particularly in Rittal VX IT racks with a cabinet frame of 2,000 mm or more, or 19-inch profile rails of 2,200 mm or more. When mounted vertically, it can be installed tool-free in the Zero-U-Space, minimizing rack space requirements. The color-coded phase marking (L1=pink, L2=black, L3=white) supports circuit identification and maintenance.
Functions and Features in Detail
The PDU provides 18 C13 outlets and 12 Combi outlets (C13/C19), each individually switchable. The switching function is performed by bistable relays, which enable low power consumption and high switching capacity, even with inrush currents up to 300 A. Relay states are retained even during power failure. The PDU includes an integrated real-time clock with battery backup (up to 10 years, replaceable) and an integrated electromagnetic buzzer for acoustic alarm signaling. The operating hour counters are resettable both globally and cyclically.
Technology Explained Simply
Power distribution is achieved via a 3-phase input. Energy measurement is performed per phase and includes voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current measurement for imbalance detection. Measurement accuracy is ±1 % (kWh) according to EN 62053-21. The PDU is self-powered and does not require external power supply. The integrated, fully redundant power supply draws power from all phases, ensuring fault-tolerant power supply. The display (TFT, 128x128 pixels, RGB, with backlight) is rotatable by 180° and replaceable, showing performance data and basic configuration. Multicolor LEDs (green/yellow/red) indicate switching states and warning or alarm threshold values.
Compatibility and Accessories
The PDU supports connection to CMC III CAN-Bus sensors for environmental monitoring, with up to 16 sensors connectable. Optionally, a Type 3 surge protection device with replaceable discharge elements during operation can be integrated, with its status monitored. Differential current measurement (Type B) is possible per input, phase, or fuse. Available accessories include CAN-Bus cables (0.5 m, 1.0 m, 1.5 m), covers for C13 and C19 sockets, mounting adapters, a universal locking device for C14/C20 plugs, a numeric code lock for CMC III, a CMC III transponder reader, and an online comfort handle VX with master key function.
Mounting and Installation
Mounting is tool-free in Rittal VX IT or TS IT racks. The delivery includes the necessary mounting hardware. The PDU is designed for vertical mounting and fits into the Zero-U-Space. The connection cable (CEE, 3 m) allows flexible positioning of the power input.
Operational Advantages
The PDU offers high operational reliability through redundant power supply and integrated fault detection. Programmable switching functions allow sequential activation of outputs after power restoration, preventing overloading peaks. Adjustable thresholds for voltage, current, and power, along with the ability to send warnings and alarms via email (SMTP), enhance operational safety. User management with rights management, LDAP(S)/Radius/Active Directory integration, and Syslog server connection (up to 2 servers) enables centralized administration. Support for protocols such as HTTP/HTTPS, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, and FTP/SFTP allows integration into DCIM software and other network management systems. Interfaces include a USB 2.0 port (USB-A) for mass configuration, firmware updates, and data logging, a CAN-Bus interface (RJ45) for environmental sensors, and a serial RS232 interface (RJ12) for LTE unit, scripting, and CLI. The PDU is specified according to EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21, and complies with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU. The operating temperature range is between 5 °C and 50 °C, with relative humidity (non-condensing) between 10 % and 95 %. Storage temperature is -20 °C to 70 °C. The housing is made of an aluminum profile, black anodized, with plastic sockets.
| General | |
| Model | PDU, switched |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | Overvoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.895 mm |
| Number of sockets and type | 18 x C13 / 12x Combi (C13/C19) |
| Rated operating voltage | 400 V AC |
| Rated current (max.) | 32 A |
| Nominal power | 22 kW |
| Power supplies | Number: 1, phases per input: 3~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Cabinet type: VX IT cabinet frame: ≥ 2,000 mm, cabinet type: VX IT 19"-profile rails: ≥ 2,200 mm |
Questions & answers
What is the delivery time of Rittal 7979345 DK PDU switched 32A 3-phase 18xC13+12xCombi?
The article Rittal 7979345 DK PDU switched 32A 3-phase 18xC13+12xCombi is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Rittal 7979345 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Rittal 7979345 DK PDU switched 32A 3-phase 18xC13+12xCombi always at the best possible price. We can give you a discount of 2% on Rittal 7979345 DK PDU switched 32A 3-phase 18xC13+12xCombi if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Rittal 7979345 DK PDU switched 32A 3-phase 18xC13+12xCombi
|
Rittal 7030090 Monitoring system CMC III CAN-Bus cable RJ45 0.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360234 Mfg Part No: 7030090 Type: DK 7030090 |
8,40 EUR
![]() ≈ £7.03 | ≈ $9.23
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360235 Mfg Part No: 7030091 Type: DK 7030091 |
10,01 EUR
![]() ≈ £8.38 | ≈ $11.00
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030092 Monitoring system CMC III CAN-Bus cable RJ45 1.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360238 Mfg Part No: 7030092 Type: DK 7030092 |
-11% 11,62 EUR 13,05 EUR
![]() ≈ £9.73 | ≈ $12.77
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Rittal 7030093 Monitoring system CMC III CAN-Bus connection cable
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360246 Mfg Part No: 7030093 Type: DK 7030093 |
13,23 EUR
![]() ≈ £11.07 | ≈ $14.54
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955010 Coverings PDU socket strip C13 socket 10 pcs
The DK 7955010 from Rittal is a socket cover for IEC 60 320 C13 sockets, used in PDU socket strips (Power Distribution Units). The product is designed to securely close unused sockets, preventing ...Lieske Part No.: 981045 Mfg Part No: 7955010 Type: DK 7955010 |
132,03 EUR
![]() ≈ £110.51 | ≈ $145.10
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955015 Coverings PDU socket strip C19 socket 10 pcs
The DK 7955015 socket cover from Rittal is a special accessory designed for use with PDU socket strips (Power Distribution Units). It is intended for the secure closure of open, unused IEC 60 320 C19 ...Lieske Part No.: 981047 Mfg Part No: 7955015 Type: DK 7955015 |
-12% 9,51 EUR 10,82 EUR
![]() ≈ £7.96 | ≈ $10.45
Made to order · Delivery time approx. 5 workdaysinfo_outline
|
|
Rittal 7000688 Mounting adapter PDU TE 8000 2 pcs
The Rittal mounting adapter DK 7000688 is designed for securing a Power Distribution Unit (PDU) to a horizontal system chassis in the VX IT enclosure type. It is specifically designed for integrating ...Lieske Part No.: 999510 Mfg Part No: 7000688 Type: DK 7000688 |
12,88 EUR
![]() ≈ £10.78 | ≈ $14.16
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979020 PDU universal lock for C14/C20 plugs
The DK 7979020 is a plug lock from the manufacturer Rittal, specifically designed for secure fixation of IEC 60 320 C14 and C20 plugs in PDU- or PSM-modules equipped with C13/C19 sockets. This lock ...Lieske Part No.: 1101023 Mfg Part No: 7979020 Type: DK 7979020 |
26,80 EUR
![]() ≈ £22.43 | ≈ $29.45
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030223 Number code lock for CMC III
The Rittal DK 7030223 is a numeric code lock for access control on enclosure doors, specifically designed for use with the CMC III system. It enables secure and controlled access authorization to ...Lieske Part No.: 1775554 Mfg Part No: 7030223 Type: DK 7030223 |
203,92 EUR
![]() ≈ £170.68 | ≈ $224.11
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030233 VX IT CMC III transponder reader, RAL 9005
The Rittal IT 7030233 is a transponder reader for access control at doors, particularly at VX IT doors and side room doors. It is used for secure release of rack, room, or enclosure doors and is ...Lieske Part No.: 1775580 Mfg Part No: 7030233 Type: IT 7030233 |
337,80 EUR
![]() ≈ £282.74 | ≈ $371.24
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030611 CMC III online comfort handle VX with Master-Key function
The Rittal IT 7030611 is a CMC III Online comfort handle VX with Master-Key function, specifically developed for use on VX and VX IT enclosures. It provides secure door locking, monitoring of the ...Lieske Part No.: 1775710 Mfg Part No: 7030611 Type: IT 7030611 |
-12% 240,01 EUR 272,99 EUR
![]() ≈ £200.89 | ≈ $263.77
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|