Rittal 7979345, EAN: 4069196015119

Rittal 7979345 PDU switched 32A 3-phase

19 Inch-Technology > Accessories/Equipment > Energy Management

Rittal 7979345 PDU switched 32A 3-phase

Lieske Part No. 894143
Mfg Part No 7979345
EAN-Code 4069196015119
Manufacturer Rittal
Here only 1.651,75 EUR
1.965,58 EUR incl. VAT

Further information for Rittal 7979345 PDU switched 32A 3-phase

General
ModelPDU, switched
MaterialAluminium profile, black anodised, mounting slots: plastic
Scope of deliveryIncluding mounting hardware
OptionsOvervoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available
Width44 mm
Depth70 mm
Length1.895 mm
Number of sockets and type18 x C13 / 12x Combi (C13/C19)
Rated operating voltage400 V AC
Rated current (max.)32 A
Nominal power22 kW
Power suppliesNumber: 1, phases per input: 3~
Connection cable length3 m
Electrical connection typeCEE
InterfacesUSB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s
PoliciesEMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU
StandardsEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21
ProtocolsWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer)
Operating temperature range5 °C...50 °C
Humidity (non-condensing)10...95 %
Storage temperature range-20 °C...70 °C
Suitable forCabinet type: VX IT cabinet frame: ≥ 2,000 mm, cabinet type: VX IT 19"-profile rails: ≥ 2,200 mm
Rittal DK 7979345 is a switched PDU (Power Distribution Unit) for use in IT network and server racks. It is designed for intelligent power distribution and monitoring in data centers and data processing facilities. The device features a compact design with a width of 44 mm, a length of 1,895 mm, and a depth of 70 mm, allowing it to be seamlessly integrated into standard 19-inch racks. The PDU is rated for an operating voltage of 400 V AC and supports a maximum rated current of 32 A and a rated power of 22 kW. Power supply is via a CEE connection cable with a length of 3 m.

Applications

The PDU is specifically designed for use in IT infrastructures, particularly in Rittal VX IT racks with a cabinet frame of 2,000 mm or more, or 19-inch profile rails of 2,200 mm or more. When mounted vertically, it can be installed tool-free in the Zero-U-Space, minimizing rack space requirements. The color-coded phase marking (L1=pink, L2=black, L3=white) supports circuit identification and maintenance.

Functions and Features in Detail

The PDU provides 18 C13 outlets and 12 Combi outlets (C13/C19), each individually switchable. The switching function is performed by bistable relays, which enable low power consumption and high switching capacity, even with inrush currents up to 300 A. Relay states are retained even during power failure. The PDU includes an integrated real-time clock with battery backup (up to 10 years, replaceable) and an integrated electromagnetic buzzer for acoustic alarm signaling. The operating hour counters are resettable both globally and cyclically.

Technology Explained Simply

Power distribution is achieved via a 3-phase input. Energy measurement is performed per phase and includes voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current measurement for imbalance detection. Measurement accuracy is ±1 % (kWh) according to EN 62053-21. The PDU is self-powered and does not require external power supply. The integrated, fully redundant power supply draws power from all phases, ensuring fault-tolerant power supply. The display (TFT, 128x128 pixels, RGB, with backlight) is rotatable by 180° and replaceable, showing performance data and basic configuration. Multicolor LEDs (green/yellow/red) indicate switching states and warning or alarm threshold values.

Compatibility and Accessories

The PDU supports connection to CMC III CAN-Bus sensors for environmental monitoring, with up to 16 sensors connectable. Optionally, a Type 3 surge protection device with replaceable discharge elements during operation can be integrated, with its status monitored. Differential current measurement (Type B) is possible per input, phase, or fuse. Available accessories include CAN-Bus cables (0.5 m, 1.0 m, 1.5 m), covers for C13 and C19 sockets, mounting adapters, a universal locking device for C14/C20 plugs, a numeric code lock for CMC III, a CMC III transponder reader, and an online comfort handle VX with master key function.

Mounting and Installation

Mounting is tool-free in Rittal VX IT or TS IT racks. The delivery includes the necessary mounting hardware. The PDU is designed for vertical mounting and fits into the Zero-U-Space. The connection cable (CEE, 3 m) allows flexible positioning of the power input.

Operational Advantages

The PDU offers high operational reliability through redundant power supply and integrated fault detection. Programmable switching functions allow sequential activation of outputs after power restoration, preventing overloading peaks. Adjustable thresholds for voltage, current, and power, along with the ability to send warnings and alarms via email (SMTP), enhance operational safety. User management with rights management, LDAP(S)/Radius/Active Directory integration, and Syslog server connection (up to 2 servers) enables centralized administration. Support for protocols such as HTTP/HTTPS, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, and FTP/SFTP allows integration into DCIM software and other network management systems. Interfaces include a USB 2.0 port (USB-A) for mass configuration, firmware updates, and data logging, a CAN-Bus interface (RJ45) for environmental sensors, and a serial RS232 interface (RJ12) for LTE unit, scripting, and CLI. The PDU is specified according to EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21, and complies with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU. The operating temperature range is between 5 °C and 50 °C, with relative humidity (non-condensing) between 10 % and 95 %. Storage temperature is -20 °C to 70 °C. The housing is made of an aluminum profile, black anodized, with plastic sockets.