Rittal 7979335 PDU Switched 16A/3P CEE 18xC13 / 3xC19

Your rating:
Average rating
product review for Rittal 7979335 PDU Switched 16A/3P CEE 18xC13 / 3xC19
( 5 / 5 ) 1 ratings
Rittal 7979335
This image may differ from the desired article.
Rittal 7979335Rittal 7979335Rittal 7979335Rittal 7979335Rittal 7979335Rittal 7979335Rittal 7979335Rittal 7979335
1.255,77 EUR 1.278,69 EUR
( 1.494,37 EUR incl. VAT )
≈ £1,051.08  |  ≈ $1,380.09
plus delivery charges: 55,00 €
Made to order · Delivery time approx. 5 workdaysinfo_outline
1x Rittal 7979335 PDU Switched 16A/3P CEE 18xC13 / 3xC19
Datasheet:file_download Download
Lieske Part No.:1101067
Mfg Part No: 7979335
UPC/EAN: 4028177947979
Weight:4.5 kg
Type:DK 7979335

Product information for Rittal 7979335:

The Rittal DK 7979335 is a switched PDU (Power Distribution Unit) for use in IT network and server racks. It serves as an intelligent power distribution unit with integrated energy measurement per phase and enables individual switching control of the output sockets. The device is designed for use in racks of type VX IT, where tool-free mounting in Zero-U-Space is possible. The PDU is housed in a compact aluminium profile with a black anodized surface and has an overall length of 1,095 mm, a width of 44 mm, and a depth of 70 mm.

Applications

The PDU is designed for use in professional IT infrastructures, particularly in server and network racks, where precise power distribution and monitoring are required. It is suitable for applications requiring central control and measurement of power consumers, for example in data centres, data hubs, or critical IT systems. The integrated energy measurement per phase enables detailed analysis of energy consumption and supports efficiency improvements in IT infrastructure.

Functions and Equipment in Detail

The PDU features a total of 21 sockets: 18 x C13 and 3 x C19, each individually switchable. The sockets are made of plastic. Power supply is via a 3-phase input (3~) with a rated operating voltage of 400 V (AC) and a maximum rated current of 16 A, corresponding to a rated power of 11 kW. The PDU is self-powered, meaning it does not require an external power supply for its control and measurement functions. The supply cable has a length of 3 m and is equipped with a CEE plug.

Technology Explained Simply

The PDU integrates a powerful CPU (ARM Cortex A8) and features a fully redundant Ethernet interface (10/100/1000 Mbit/s), ensuring a reliable network connection. Measurement accuracy is ±1 % (kWh) according to standard EN 62053-21. The integrated real-time clock is buffered by a replaceable battery (maximum 10-year lifespan) to maintain time and operating hour counting even during power failure. The PDU offers programmable switching logic, for example enabling sequential switching of outputs after power restoration to avoid overloading peaks. Relay states are stored even during power failure. An integrated electromagnetic buzzer provides acoustic alarm notification for warning or alarm thresholds.

Compatibility and Accessories

The PDU is designed for racks with a cabinet frame ≥ 1,200 mm and 48,3 cm ( 19 inch ) profile rails ≥ 1,800 mm. It is supplied with a tool-free mounting kit for VX IT racks. The sockets are colour-coded (L1=pink, L2=black, L3=white) to facilitate phase assignment. Available accessories include various CAN-Bus cables for the CMC III monitoring system, covers for C13 and C19 sockets, mounting adapters, and a PDU surge protector (Type 3, 11 kW, 50 A). The PDU supports connection of up to 16 environmental sensors via CAN-Bus.

Mounting and Installation

Mounting is tool-free in the Zero-U-Space of VX IT or TS IT racks. The device is supplied with mounting hardware required for installation in the rack. The display/controller unit is rotatable and replaceable within the housing by 180°, allowing flexible adaptation to the mounting position. The supply cable is integrated and has a length of 3 m.

t
Operational Advantages

The PDU offers high operational reliability through redundant power supply from all phases and fault-tolerant power supply. The integrated energy measurement per phase enables precise consumption analysis. The switching function per output socket allows flexible control of connected devices. Support for protocols such as SNMP, Modbus/TCP, OPC-UA, and MIB enables integration into DCIM software and other monitoring systems. The PDU also supports email alerts (SMTP), Syslog server connection (up to 2 servers), user management with rights management, and integration with LDAP(S)/Radius/Active Directory. The operating temperature range is between 5 °C and 50 °C, and the relative humidity (non-condensing) is between 10 % and 95 %.

The PDU is certified in accordance with the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, as well as standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21. Interfaces include USB 2.0 (USB-A), CAN-Bus (RJ45), RS232 (RJ12), and a fully redundant Ethernet interface. Protocol support includes HTTP, HTTPS, SSL, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, FTP/SFTP, and MIB for integration into external systems.

Note: Batteries are not included in the delivery scope.

General
ModelPDU, switched
MaterialAluminium profile, black anodised, mounting slots: plastic
Scope of deliveryIncluding mounting hardware
Width44 mm
Depth70 mm
Length1.095 mm
Number of sockets and type18 x C13 / 3 x C19
Socket outlets18 x C 13, 3 x C 19
Rated operating voltage400 V (AC)
Rated current (max.)16 A
Nominal power11 kW
Power suppliesPhases per input: 3~
Connection cable length3 m
Electrical connection typeCEE
InterfacesUSB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s
PoliciesEMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU
StandardsEN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21
ProtocolsWeb server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer)
Operating temperature range5 °C...50 °C
Humidity (non-condensing)10...95 %
Storage temperature range-20 °C...70 °C
Suitable forHousing type: VX IT cabinet frame: ≥ 1,200 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm


Product data sheet
Datasheet for Rittal 7979335, EAN: 4028177947979

Questions & answers

What is the delivery time of Rittal 7979335 PDU Switched 16A/3P CEE 18xC13 / 3xC19?

The article Rittal 7979335 PDU Switched 16A/3P CEE 18xC13 / 3xC19 is currently not in stock and must be ordered on a per-order basis.

According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Rittal 7979335 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Rittal 7979335 PDU Switched 16A/3P CEE 18xC13 / 3xC19 always at the best possible price. We can give you a discount of 2% on Rittal 7979335 PDU Switched 16A/3P CEE 18xC13 / 3xC19 if you choose payment in advance on ordering.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Fitting accessory for Rittal 7979335 PDU Switched 16A/3P CEE 18xC13 / 3xC19

Rittal 7030090 Monitoring system CMC III CAN-Bus cable RJ45 0.5 m Rittal LogoRittal 7030090 Monitoring system CMC III CAN-Bus cable RJ45 0.5 m This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.
Applications: For connecting the CAN bus units.
Information and power ...

Lieske Part No.: 360234
Mfg Part No: 7030090
Type: DK 7030090
8,40 EUR
Rittal 7030090 plus VAT
≈ £7.03  |  ≈ $9.23
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m Rittal LogoRittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.
Applications: For connecting the CAN bus units.
Information and power ...

Lieske Part No.: 360235
Mfg Part No: 7030091
Type: DK 7030091
10,01 EUR
Rittal 7030091 plus VAT
≈ £8.38  |  ≈ $11.00
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7030092 Monitoring system CMC III CAN-Bus cable RJ45 1.5 m Rittal LogoRittal 7030092 Monitoring system CMC III CAN-Bus cable RJ45 1.5 m This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.
Applications: For connecting the CAN bus units.
Information and power ...

Lieske Part No.: 360238
Mfg Part No: 7030092
Type: DK 7030092
-11% 11,62 EUR 13,05 EUR
Rittal 7030092 plus VAT
≈ £9.73  |  ≈ $12.77
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
Rittal 7030093 Monitoring system CMC III CAN-Bus connection cable Rittal LogoRittal 7030093 Monitoring system CMC III CAN-Bus connection cable This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.
Applications: For connecting the CAN bus units.
Information and power ...

Lieske Part No.: 360246
Mfg Part No: 7030093
Type: DK 7030093
13,23 EUR
Rittal 7030093 plus VAT
≈ £11.07  |  ≈ $14.54
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7955010 Coverings PDU socket strip C13 socket 10 pcs Rittal LogoRittal 7955010 Coverings PDU socket strip C13 socket 10 pcs The DK 7955010 from Rittal is a socket cover for IEC 60 320 C13 sockets, used in PDU socket strips (Power Distribution Units). The product is designed to securely close unused sockets, preventing ...

Lieske Part No.: 981045
Mfg Part No: 7955010
Type: DK 7955010
132,03 EUR
Rittal 7955010 plus VAT
≈ £110.51  |  ≈ $145.10
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7955015 Coverings PDU socket strip C19 socket 10 pcs Rittal LogoRittal 7955015 Coverings PDU socket strip C19 socket 10 pcs The DK 7955015 socket cover from Rittal is a special accessory designed for use with PDU socket strips (Power Distribution Units). It is intended for the secure closure of open, unused IEC 60 320 C19 ...

Lieske Part No.: 981047
Mfg Part No: 7955015
Type: DK 7955015
-12% 9,51 EUR 10,82 EUR
Rittal 7955015 plus VAT
≈ £7.96  |  ≈ $10.45
Made to order · Delivery time approx. 5 workdaysinfo_outline
Rittal 7000688 Mounting adapter PDU TE 8000 2 pcs Rittal LogoRittal 7000688 Mounting adapter PDU TE 8000 2 pcs The Rittal mounting adapter DK 7000688 is designed for securing a Power Distribution Unit (PDU) to a horizontal system chassis in the VX IT enclosure type. It is specifically designed for integrating ...

Lieske Part No.: 999510
Mfg Part No: 7000688
Type: DK 7000688
12,88 EUR
Rittal 7000688 plus VAT
≈ £10.78  |  ≈ $14.16
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7979020 PDU universal lock for C14/C20 plugs Rittal LogoRittal 7979020 PDU universal lock for C14/C20 plugs The DK 7979020 is a plug lock from the manufacturer Rittal, specifically designed for secure fixation of IEC 60 320 C14 and C20 plugs in PDU- or PSM-modules equipped with C13/C19 sockets. This lock ...

Lieske Part No.: 1101023
Mfg Part No: 7979020
Type: DK 7979020
26,80 EUR
Rittal 7979020 plus VAT
≈ £22.43  |  ≈ $29.45
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7030223 Number code lock for CMC III Rittal LogoRittal 7030223 Number code lock for CMC III The Rittal DK 7030223 is a numeric code lock for access control on enclosure doors, specifically designed for use with the CMC III system. It enables secure and controlled access authorization to ...

Lieske Part No.: 1775554
Mfg Part No: 7030223
Type: DK 7030223
203,92 EUR
Rittal 7030223 plus VAT
≈ £170.68  |  ≈ $224.11
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7030233 VX IT CMC III transponder reader, RAL 9005 Rittal LogoRittal 7030233 VX IT CMC III transponder reader, RAL 9005 The Rittal IT 7030233 is a transponder reader for access control at doors, particularly at VX IT doors and side room doors. It is used for secure release of rack, room, or enclosure doors and is ...

Lieske Part No.: 1775580
Mfg Part No: 7030233
Type: IT 7030233
337,80 EUR
Rittal 7030233 plus VAT
≈ £282.74  |  ≈ $371.24
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7979723 PDU surge protection, rated power: 11 kW, rated current: 50 A, Rittal LogoRittal 7979723 PDU surge protection, rated power: 11 kW, rated current: 50 A, The Rittal DK 7979723 is an overvoltage protection module of type 3, specifically designed for end-device protection in electrical installations. It serves as the final stage in the overvoltage ...

Lieske Part No.: 1775587
Mfg Part No: 7979723
Type: DK 7979723
218,73 EUR
Rittal 7979723 plus VAT
≈ £183.08  |  ≈ $240.38
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7030611 CMC III online comfort handle VX with Master-Key function Rittal LogoRittal 7030611 CMC III online comfort handle VX with Master-Key function The Rittal IT 7030611 is a CMC III Online comfort handle VX with Master-Key function, specifically developed for use on VX and VX IT enclosures. It provides secure door locking, monitoring of the ...

Lieske Part No.: 1775710
Mfg Part No: 7030611
Type: IT 7030611
-12% 240,01 EUR 272,99 EUR
Rittal 7030611 plus VAT
≈ £200.89  |  ≈ $263.77
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
Rittal 7979713 PDU RCM 48,3 cm ( 19 inch )-Inline Meter, 3-phase, rated power: 1 Rittal LogoRittal 7979713 PDU RCM 48,3 cm ( 19 inch )-Inline Meter, 3-phase, rated power: 1 The Rittal DK 7979713 is an Inline Meter, an autonomous energy monitoring unit in the 1 HE/48,3 cm ( 19 inch ) form factor, which is inserted into the supply line of a consumer, a PDU basic, or a ...

Lieske Part No.: 1989426
Mfg Part No: 7979713
Type: DK 7979713
1.040,06 EUR
Rittal 7979713 plus VAT
≈ £870.53  |  ≈ $1,143.03
Delivery time from supplier's stock (ca.) 6 workdaysinfo_outline
Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Rittal 7979335 PDU Switched 16A/3P CEE 18xC13 3xC19
Rittal 7979335 PDU Switched 16A/3P CEE 18xC13 / 3xC19
1.255,77 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Rittal 7979335 PDU Switched 16A/3P CEE 18xC13 3xC19
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
3 + 5 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.