Rittal 7979321 DK PDU switched 32A 1-phase 12xC13+12xCombi
|
1.365,28 EUR 1.423,70 EUR |
|
|
( 1.624,68 EUR incl. VAT ) ≈ £1,142.74 | ≈ $1,500.44 plus delivery charges: 55,00 € |
|
| Made to order · Delivery time approx. 5 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 894090 |
| Mfg Part No: | 7979321 |
| UPC/EAN: | 4069196015133 |
| Weight: | 0.123 kg |
| Type: | DK 7979321 |
Product information for Rittal 7979321:
Applications
The PDU is specifically designed for use in Rittal VX IT and TS IT racks, particularly in cabinet frames or 48,3 cm ( 19 inch ) profile rails with a minimum length of 1,800 mm. When mounted vertically, it can be installed toollessly in Zero-U-Space, saving rack space. The colour-coded phase marking (L1=pink, L2=black, L3=white) facilitates assignment and maintenance. The PDU is intended for use in IT infrastructures where precise energy measurement, load monitoring and remote control are required.
Functions and Equipment in Detail
The PDU features 12 C13 sockets and 12 Combi sockets (C13/C19), each individually switchable via an integrated control unit. The switching function is performed by bistable relays, enabling low power consumption and high switching capacity even at high inrush currents up to 300 A. The relay states are retained even during power failure. The PDU offers programmable switching logic, including sequential switching on after power restoration, to avoid overloads. The switching behaviour after power restoration can be programmed to on", "off", or "last status.
Technology Explained Simply
The integrated energy measurement is performed per phase and records voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current. Measurement accuracy is ±1 % (kWh) according to EN 62053-21. The PDU includes an integrated real-time clock with battery backup (up to 10 years, replaceable) and an integrated electromagnetic buzzer for acoustic alarm. Adjustable thresholds for voltage, current and power enable warnings and alarms in case of exceedances. An operating hour counter (total and cyclic, resettable) supports operational monitoring.
Compatibility and Accessories
The PDU is equipped with a fully redundant Ethernet interface (10/100/1000 Mbit/s), suitable for integration into DCIM software and network monitoring systems. It supports protocols such as HTTP/HTTPS, SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, FTP/SFTP. The CAN-Bus interface (RJ45) allows connection of up to 16 CMC III environmental sensors for monitoring temperature, humidity or other parameters. Optionally, a Type 3 surge protection device with replaceable discharge elements during operation can be integrated, with its status monitored. Differential current measurement (Type B) per input/phase/fuse is also possible.
Mounting and Installation
Mounting is toolless in the Zero-U-Space of Rittal VX IT or TS IT racks. The device is supplied with mounting hardware intended for rack installation. The display unit is rotatable by 180° and replaceable to ensure optimal visibility. The PDU is self-powered, requiring no external power supply. The integrated power supply is fault-tolerant and redundantly designed across all phases.
Operational Advantages
The PDU offers high operational reliability through redundant power supply and integrated alarm functions. Remote control via network and serial interfaces enables central monitoring and control. Support for LDAP(S), Radius, Active Directory and Syslog servers (up to 2 servers) allows integration into existing IT infrastructures. The use of own certificates and TLS 1.2 ensures secure communication. The PDU is designed for operating temperatures from 5 °C to 50 °C and humidity levels from 10 % to 95 % (non-condensing). The storage temperature range is -20 °C to 70 °C. The PDU is certified according to EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6 and EN 62053-21, as well as the EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU.
Scope of Delivery
Includes mounting hardware for installation in the rack.
| General | |
| Model | PDU, switched |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | Overvoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.495 mm |
| Number of sockets and type | 12 x C13 / 12x Combi (C13/C19) |
| Rated operating voltage | 230 V AC |
| Rated current (max.) | 32 A |
| Nominal power | 7,4 kW |
| Power supplies | Number: 1, Phases per input: 1~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,800 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm |
Questions & answers
What is the delivery time of Rittal 7979321 DK PDU switched 32A 1-phase 12xC13+12xCombi?
The article Rittal 7979321 DK PDU switched 32A 1-phase 12xC13+12xCombi is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Rittal 7979321 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Rittal 7979321 DK PDU switched 32A 1-phase 12xC13+12xCombi always at the best possible price. We can give you a discount of 2% on Rittal 7979321 DK PDU switched 32A 1-phase 12xC13+12xCombi if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Rittal 7979321 DK PDU switched 32A 1-phase 12xC13+12xCombi
|
Rittal 7030090 Monitoring system CMC III CAN-Bus cable RJ45 0.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360234 Mfg Part No: 7030090 Type: DK 7030090 |
8,40 EUR
![]() ≈ £7.03 | ≈ $9.23
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360235 Mfg Part No: 7030091 Type: DK 7030091 |
10,01 EUR
![]() ≈ £8.38 | ≈ $11.00
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030092 Monitoring system CMC III CAN-Bus cable RJ45 1.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360238 Mfg Part No: 7030092 Type: DK 7030092 |
-11% 11,62 EUR 13,05 EUR
![]() ≈ £9.73 | ≈ $12.77
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Rittal 7030093 Monitoring system CMC III CAN-Bus connection cable
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360246 Mfg Part No: 7030093 Type: DK 7030093 |
13,23 EUR
![]() ≈ £11.07 | ≈ $14.54
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955010 Coverings PDU socket strip C13 socket 10 pcs
The DK 7955010 from Rittal is a socket cover for IEC 60 320 C13 sockets, used in PDU socket strips (Power Distribution Units). The product is designed to securely close unused sockets, preventing ...Lieske Part No.: 981045 Mfg Part No: 7955010 Type: DK 7955010 |
132,03 EUR
![]() ≈ £110.51 | ≈ $145.10
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955015 Coverings PDU socket strip C19 socket 10 pcs
The DK 7955015 socket cover from Rittal is a special accessory designed for use with PDU socket strips (Power Distribution Units). It is intended for the secure closure of open, unused IEC 60 320 C19 ...Lieske Part No.: 981047 Mfg Part No: 7955015 Type: DK 7955015 |
-12% 9,51 EUR 10,82 EUR
![]() ≈ £7.96 | ≈ $10.45
Made to order · Delivery time approx. 5 workdaysinfo_outline
|
|
Rittal 7000688 Mounting adapter PDU TE 8000 2 pcs
The Rittal mounting adapter DK 7000688 is designed for securing a Power Distribution Unit (PDU) to a horizontal system chassis in the VX IT enclosure type. It is specifically designed for integrating ...Lieske Part No.: 999510 Mfg Part No: 7000688 Type: DK 7000688 |
12,88 EUR
![]() ≈ £10.78 | ≈ $14.16
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979020 PDU universal lock for C14/C20 plugs
The DK 7979020 is a plug lock from the manufacturer Rittal, specifically designed for secure fixation of IEC 60 320 C14 and C20 plugs in PDU- or PSM-modules equipped with C13/C19 sockets. This lock ...Lieske Part No.: 1101023 Mfg Part No: 7979020 Type: DK 7979020 |
26,80 EUR
![]() ≈ £22.43 | ≈ $29.45
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030223 Number code lock for CMC III
The Rittal DK 7030223 is a numeric code lock for access control on enclosure doors, specifically designed for use with the CMC III system. It enables secure and controlled access authorization to ...Lieske Part No.: 1775554 Mfg Part No: 7030223 Type: DK 7030223 |
203,92 EUR
![]() ≈ £170.68 | ≈ $224.11
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030233 VX IT CMC III transponder reader, RAL 9005
The Rittal IT 7030233 is a transponder reader for access control at doors, particularly at VX IT doors and side room doors. It is used for secure release of rack, room, or enclosure doors and is ...Lieske Part No.: 1775580 Mfg Part No: 7030233 Type: IT 7030233 |
337,80 EUR
![]() ≈ £282.74 | ≈ $371.24
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030611 CMC III online comfort handle VX with Master-Key function
The Rittal IT 7030611 is a CMC III Online comfort handle VX with Master-Key function, specifically developed for use on VX and VX IT enclosures. It provides secure door locking, monitoring of the ...Lieske Part No.: 1775710 Mfg Part No: 7030611 Type: IT 7030611 |
-12% 240,01 EUR 272,99 EUR
![]() ≈ £200.89 | ≈ $263.77
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|