Rittal 7979211 PDU metered 16A/1P CEE 10xCEE 7/3 Schuko
|
-8% 629,40 EUR 685,61 EUR |
|
|
( 748,99 EUR incl. VAT ) ≈ £526.81 | ≈ $691.71 plus delivery charges: 55,00 € |
|
| Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline | |
| In Stock: >10 pieces | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 1954060 |
| Mfg Part No: | 7979211 |
| UPC/EAN: | 4028177947641 |
| Weight: | 3.7 kg |
| Type: | DK 7979211 |
Product information for Rittal 7979211:
Applications
The PDU is designed for use in IT and network racks, particularly in environments where precise energy consumption measurement and control are required. It is suitable for server racks, network equipment, and other IT systems featuring a 48,3 cm ( 19 inch ) mounting structure. Mounting is possible in racks with a cabinet frame of at least 1,200 mm or 48,3 cm ( 19 inch ) profile rails of at least 1,800 mm. The color-coded phase marking (L1=pink, L2=black, L3=white) supports identification and maintenance.
Functions and Equipment in Detail
The PDU features a powerful CPU (ARM Cortex A8) and enables measurement per phase or input. Measurement accuracy is ±1 % (kWh) according to standard EN 62053-21. An integrated real-time clock with battery backup (up to 10 years, replaceable) ensures continuous time measurement even during power failure. An integrated electromagnetic buzzer enables acoustic alarm signaling for overloads. Adjustable thresholds for voltage, current, and power support proactive monitoring. An operating hour counter (total and cyclic, resettable) documents usage duration. The device is self-powered, requires no external power supply, and features low power consumption.
Technology Explained Simply
Power distribution is handled by an integrated, fully redundant power supply unit, which can be powered from all phases, ensuring fault-tolerant power supply. The display (128x128 pixels, TFT, RGB, with backlight) is rotatable by 180° and replaceable, optimizing the display of performance data and basic configuration. Position sensors ensure correct display on the web interface. Measurement functions include voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current measurement for unbalanced load detection. For PDUs with integrated fuses, fuse monitoring is provided.
Compatibility and Accessories
The PDU is equipped with a variety of interfaces: a USB 2.0 interface (USB-A) for mass configuration, firmware updates, and data logging; a CAN-Bus interface (RJ45) for up to 16 environmental sensors (CMC III); a serial RS232 interface (RJ12) for LTE unit, scripting, and CLI; and a fully redundant Ethernet interface (10/100/1000 Mbit/s). Protocol support includes web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into DCIM software, and FTP/SFTP for updates and file transfers. Additionally, connection to LDAP(S), Radius, Active Directory, and Syslog servers (up to 2 servers) is possible. Email alerting on alarm (SMTP) and user management with rights management are also integrated. Optionally, a Type 3 surge protection device with replaceable discharge elements during operation and status monitoring can be integrated. Differential current measurement (Type B) per input/phase/fuse is also available. Monitoring of the optional surge protection is possible. CMC III CAN-Bus sensors can be connected, with support for up to 16 sensors. Other housing colors are available optionally.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT- or TS IT-racks. The delivery includes mounting hardware. The PDU is designed for vertical mounting and fits in racks with a cabinet frame of at least 1,200 mm or 48,3 cm ( 19 inch ) profile rails of at least 1,800 mm. The connection cable (CEE, 3 m) allows flexible positioning of the power input.
Operational Advantages
The PDU offers high measurement accuracy, redundant power supply, and comprehensive network integration. The integrated real-time clock and operating hour counter support maintenance planning. Tool-free mounting and color-coded phase marking simplify installation and maintenance. Support for protocols such as SNMP, Modbus/TCP, and OPC-UA enables integration into existing monitoring and management systems. The ability to use custom certificates and TLS 1.2 enhances communication security. The integrated alarm output (relay output, changeover contact) enables direct response to critical conditions.
Operating Conditions
The operating temperature range is 5 °C to 50 °C, with non-condensing humidity between 10 % and 95 %. Storage temperature is -20 °C to 70 °C. The PDU is designed for indoor use and complies with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU. Standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21 are met.
| General | |
| Model | PDU, metered |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | Overvoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available |
| Description of measurement functions | measurement per phase or input, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact) |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.095 mm |
| Number of sockets and type | 10 x Schuko (Type F, CEE 7/3) |
| Rated operating voltage | 230 V (AC) |
| Rated current (max.) | 16 A |
| Nominal power | 3,7 kW |
| Power supplies | Number: 1, Phases per input: 1~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,200 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm |
Questions & answers
What is the delivery time of Rittal 7979211 PDU metered 16A/1P CEE 10xCEE 7/3 Schuko?
The article Rittal 7979211 PDU metered 16A/1P CEE 10xCEE 7/3 Schuko is currently in stock
According to our experience the article is ready for dispatch within 12 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Rittal 7979211 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Rittal 7979211 PDU metered 16A/1P CEE 10xCEE 7/3 Schuko always at the best possible price. We can give you a discount of 2% on Rittal 7979211 PDU metered 16A/1P CEE 10xCEE 7/3 Schuko if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Rittal 7979211 PDU metered 16A/1P CEE 10xCEE 7/3 Schuko
|
Rittal 7030090 Monitoring system CMC III CAN-Bus cable RJ45 0.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360234 Mfg Part No: 7030090 Type: DK 7030090 |
8,40 EUR
![]() ≈ £7.03 | ≈ $9.23
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360235 Mfg Part No: 7030091 Type: DK 7030091 |
10,01 EUR
![]() ≈ £8.38 | ≈ $11.00
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030092 Monitoring system CMC III CAN-Bus cable RJ45 1.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360238 Mfg Part No: 7030092 Type: DK 7030092 |
-11% 11,62 EUR 13,05 EUR
![]() ≈ £9.73 | ≈ $12.77
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Rittal 7030093 Monitoring system CMC III CAN-Bus connection cable
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360246 Mfg Part No: 7030093 Type: DK 7030093 |
13,23 EUR
![]() ≈ £11.07 | ≈ $14.54
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955010 Coverings PDU socket strip C13 socket 10 pcs
The DK 7955010 from Rittal is a socket cover for IEC 60 320 C13 sockets, used in PDU socket strips (Power Distribution Units). The product is designed to securely close unused sockets, preventing ...Lieske Part No.: 981045 Mfg Part No: 7955010 Type: DK 7955010 |
132,03 EUR
![]() ≈ £110.51 | ≈ $145.10
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955015 Coverings PDU socket strip C19 socket 10 pcs
The DK 7955015 socket cover from Rittal is a special accessory designed for use with PDU socket strips (Power Distribution Units). It is intended for the secure closure of open, unused IEC 60 320 C19 ...Lieske Part No.: 981047 Mfg Part No: 7955015 Type: DK 7955015 |
-12% 9,51 EUR 10,82 EUR
![]() ≈ £7.96 | ≈ $10.45
Made to order · Delivery time approx. 5 workdaysinfo_outline
|
|
Rittal 7000688 Mounting adapter PDU TE 8000 2 pcs
The Rittal mounting adapter DK 7000688 is designed for securing a Power Distribution Unit (PDU) to a horizontal system chassis in the VX IT enclosure type. It is specifically designed for integrating ...Lieske Part No.: 999510 Mfg Part No: 7000688 Type: DK 7000688 |
12,88 EUR
![]() ≈ £10.78 | ≈ $14.16
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979020 PDU universal lock for C14/C20 plugs
The DK 7979020 is a plug lock from the manufacturer Rittal, specifically designed for secure fixation of IEC 60 320 C14 and C20 plugs in PDU- or PSM-modules equipped with C13/C19 sockets. This lock ...Lieske Part No.: 1101023 Mfg Part No: 7979020 Type: DK 7979020 |
26,80 EUR
![]() ≈ £22.43 | ≈ $29.45
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979711 RCM measuring module 48,3 cm ( 19 inch ) inline meter 16A/1P CEE input and output
The Rittal DK 7979711 is an autonomous energy monitoring module in the 1 HE/48,3 cm ( 19 inch ) form factor, specifically developed for integration into existing power supply systems. It serves as an ...Lieske Part No.: 1101086 Mfg Part No: 7979711 Type: DK 7979711 |
-10% 983,25 EUR 1.086,84 EUR
![]() ≈ £822.98 | ≈ $1,080.59
Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline
|
|
Rittal 7030223 Number code lock for CMC III
The Rittal DK 7030223 is a numeric code lock for access control on enclosure doors, specifically designed for use with the CMC III system. It enables secure and controlled access authorization to ...Lieske Part No.: 1775554 Mfg Part No: 7030223 Type: DK 7030223 |
203,92 EUR
![]() ≈ £170.68 | ≈ $224.11
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030233 VX IT CMC III transponder reader, RAL 9005
The Rittal IT 7030233 is a transponder reader for access control at doors, particularly at VX IT doors and side room doors. It is used for secure release of rack, room, or enclosure doors and is ...Lieske Part No.: 1775580 Mfg Part No: 7030233 Type: IT 7030233 |
337,80 EUR
![]() ≈ £282.74 | ≈ $371.24
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979721 Surge protection module Type 3
The Rittal DK 7979721 is an overvoltage protection module of Type 3, specifically designed for end-device protection in 19-inch technology and enclosures. It serves as the final stage in the ...Lieske Part No.: 1775589 Mfg Part No: 7979721 Type: DK 7979721 |
155,83 EUR
![]() ≈ £130.43 | ≈ $171.26
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030611 CMC III online comfort handle VX with Master-Key function
The Rittal IT 7030611 is a CMC III Online comfort handle VX with Master-Key function, specifically developed for use on VX and VX IT enclosures. It provides secure door locking, monitoring of the ...Lieske Part No.: 1775710 Mfg Part No: 7030611 Type: IT 7030611 |
-12% 240,01 EUR 272,99 EUR
![]() ≈ £200.89 | ≈ $263.77
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979713 PDU RCM 48,3 cm ( 19 inch )-Inline Meter, 3-phase, rated power: 1
The Rittal DK 7979713 is an Inline Meter, an autonomous energy monitoring unit in the 1 HE/48,3 cm ( 19 inch ) form factor, which is inserted into the supply line of a consumer, a PDU basic, or a ...Lieske Part No.: 1989426 Mfg Part No: 7979713 Type: DK 7979713 |
1.040,06 EUR
![]() ≈ £870.53 | ≈ $1,143.03