| General |
| Model | PDU, metered |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | Overvoltage protection Type 3 with replaceable diverters during operation, with status monitoring, integrable in PDU housing, differential current measurement (Type B) per input/phase/fuse, monitoring of optional overvoltage protection, CMC III CAN-Bus sensors for environment monitoring connectable, max. 16 sensors, other housing colours available |
| Description of measurement functions | measurement per phase or input, powerful CPU (ARM Cortex A8), digital input (potential-free contact), additional alarm output/relay output (changeover contact) |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.095 mm |
| Number of sockets and type | 10 x Schuko (Type F, CEE 7/3) |
| Rated operating voltage | 230 V (AC) |
| Rated current (max.) | 16 A |
| Nominal power | 3,7 kW |
| Power supplies | Number: 1, Phases per input: 1~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,200 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm |
The Rittal DK 7979211 is a
PDU (Power Distribution Unit) with integrated
energy measurement per phase, designed for use in IT network and server racks. As a
metered PDU, it provides detailed power consumption data and enables precise monitoring of energy efficiency in data centers and IT infrastructures. The device features a compact aluminum housing in black anodized finish and is suitable for vertical mounting in the Zero-U-Space of Rittal VX IT- or TS IT-racks, with tool-free installation. Power distribution is provided via 10 Schuko outlets (Type F, CEE 7/3), supporting a maximum rated power of 3.7 kW at 230 V (AC) and a rated current of 16 A. Power input is via a CEE connection cable with a length of 3 m.
Applications
The PDU is designed for use in IT and network racks, particularly in environments where precise energy consumption measurement and control are required. It is suitable for server racks, network equipment, and other IT systems featuring a 48,3 cm ( 19 inch ) mounting structure. Mounting is possible in racks with a cabinet frame of at least 1,200 mm or 48,3 cm ( 19 inch ) profile rails of at least 1,800 mm. The color-coded phase marking (L1=pink, L2=black, L3=white) supports identification and maintenance.
Functions and Equipment in Detail
The PDU features a powerful CPU (ARM Cortex A8) and enables measurement per phase or input. Measurement accuracy is ±1 % (kWh) according to standard EN 62053-21. An integrated real-time clock with battery backup (up to 10 years, replaceable) ensures continuous time measurement even during power failure. An integrated electromagnetic buzzer enables acoustic alarm signaling for overloads. Adjustable thresholds for voltage, current, and power support proactive monitoring. An operating hour counter (total and cyclic, resettable) documents usage duration. The device is self-powered, requires no external power supply, and features low power consumption.
Technology Explained Simply
Power distribution is handled by an integrated, fully redundant power supply unit, which can be powered from all phases, ensuring fault-tolerant power supply. The display (128x128 pixels, TFT, RGB, with backlight) is rotatable by 180° and replaceable, optimizing the display of performance data and basic configuration. Position sensors ensure correct display on the web interface. Measurement functions include voltage, current, frequency, active power, active energy, apparent power, apparent energy, power factor (cosPhi), phase angle, and neutral conductor current measurement for unbalanced load detection. For PDUs with integrated fuses, fuse monitoring is provided.
Compatibility and Accessories
The PDU is equipped with a variety of interfaces: a USB 2.0 interface (USB-A) for mass configuration, firmware updates, and data logging; a CAN-Bus interface (RJ45) for up to 16 environmental sensors (CMC III); a serial RS232 interface (RJ12) for LTE unit, scripting, and CLI; and a fully redundant Ethernet interface (10/100/1000 Mbit/s). Protocol support includes web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into DCIM software, and FTP/SFTP for updates and file transfers. Additionally, connection to LDAP(S), Radius, Active Directory, and Syslog servers (up to 2 servers) is possible. Email alerting on alarm (SMTP) and user management with rights management are also integrated. Optionally, a Type 3 surge protection device with replaceable discharge elements during operation and status monitoring can be integrated. Differential current measurement (Type B) per input/phase/fuse is also available. Monitoring of the optional surge protection is possible. CMC III CAN-Bus sensors can be connected, with support for up to 16 sensors. Other housing colors are available optionally.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT- or TS IT-racks. The delivery includes mounting hardware. The PDU is designed for vertical mounting and fits in racks with a cabinet frame of at least 1,200 mm or 48,3 cm ( 19 inch ) profile rails of at least 1,800 mm. The connection cable (CEE, 3 m) allows flexible positioning of the power input.
Operational Advantages
The PDU offers high measurement accuracy, redundant power supply, and comprehensive network integration. The integrated real-time clock and operating hour counter support maintenance planning. Tool-free mounting and color-coded phase marking simplify installation and maintenance. Support for protocols such as SNMP, Modbus/TCP, and OPC-UA enables integration into existing monitoring and management systems. The ability to use custom certificates and TLS 1.2 enhances communication security. The integrated alarm output (relay output, changeover contact) enables direct response to critical conditions.
Operating Conditions
The operating temperature range is 5 °C to 50 °C, with non-condensing humidity between 10 % and 95 %. Storage temperature is -20 °C to 70 °C. The PDU is designed for indoor use and complies with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU. Standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21 are met.