Rittal 7030150 Monitoring system CMC III analog differential pressure sensor
|
-24% 263,24 EUR 347,21 EUR |
|
|
( 313,26 EUR incl. VAT ) ≈ £220.33 | ≈ $289.30 plus delivery charges: 55,00 € |
|
| Made to order · Delivery time approx. 5 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 1768249 |
| Mfg Part No: | 7030150 |
| UPC/EAN: | 4028177659537 |
| Weight: | 0.539 kg |
| Type: | DK 7030150 |
Product information for Rittal 7030150:
Applications
The sensor is designed for use in IT infrastructures, industrial environments and building technology. It monitors pressure conditions in enclosures, rooms and containers to ensure the efficiency of cooling and ventilation systems. It is particularly suitable for applications such as cold aisle containment, where a constant pressure difference between the cold and hot aisles must be monitored to ensure optimal air circulation. It can also be used in underfloor systems for server cooling to monitor airflow.
Functions and Equipment in Detail
The sensor measures differential pressure in the range of -500 Pa to +500 Pa with a measurement accuracy of ±3 % and a resolution of 1 Pa. Settings for warning and alarm thresholds can be configured via the software of the CMC III Processing Unit and are stored directly in the sensor. The integrated multicolour LED serves as a status indicator and signals the operating state. Automatic detection upon connection to the system enables quick plug-and-play deployment.
Technology Explained Simply
The sensor operates on the principle of differential pressure measurement. It detects air pressure at two points in the space, defined by an air tube, and calculates the difference. This measurement is crucial for identifying pressure losses, airflow disruptions or inefficient cooling in enclosed spaces. The data is transmitted via two RJ45 connectors to the CAN-Bus, allowing the sensor to be directly connected to the Processing Unit or integrated into an existing bus system. The protection rating IP 30 according to EN 60529 protects against mechanical impacts and limited access, but not against dust or water.
Compatibility and Accessories
The sensor is designed for use with CMC III Processing Units and can be directly connected to them. It is compatible with various system configurations: up to 32 participants per IoT Interface, up to 32 participants per PU, up to 4 participants per PU compact, and up to 16 participants per PDU. Accessories include CAN-Bus cables in various lengths (0.5 m to 10.0 m) and connection cables, enabling flexible installation. Alternatively, the sensor DK 7010150 may be considered as a successor or similar model.
Mounting and Installation
The sensor is supplied with a mounting plate and fastening materials, enabling easy installation on enclosure walls or other suitable surfaces. Dimensions are 110 mm (width) × 30 mm (height) × 40 mm (depth). The housing is made of plastic, with the front in RAL 9005 and the housing in RAL 7035. The front is smooth, the housing is textured. Installation takes place at a suitable location within the monitored area, with air tubes routed to the measurement points.
Advantages in Operation
The sensor enables precise and continuous monitoring of pressure conditions in critical environments. The integrated CAN-Bus technology and plug-and-play function reduce installation time and complexity. Storing settings directly in the sensor ensures stable configuration even during system changes. The operating temperature range of 0 °C to 55 °C and relative humidity of 5 % to 95 % (non-condensing) make it suitable for a wide range of operating conditions. The integrated LED indicator supports quick diagnosis of the operating status.
The delivery includes the sensor, a mounting plate and fastening materials. Additionally, according to the manufacturer's data sheet, a 5 m long air tube and a quick start guide are included. The packaging unit is 1 piece.
| General | |
| Model | Analog differential pressure sensor |
| Applications | Monitoring of cabinets in IT, industry and building technology. Monitoring of cabinets, rooms and containers in IT environment. |
| Function principle | Settings can be made via the CMC III Processing Unit or via the IoT Interface. The CMC III differential pressure sensor measures air pressure at two points in the room and displays the pressure difference between the measurement points. The two points in the room are defined using a thin tube connected to the sensor. Application: cold aisle containment, raised floor |
| Material | Plastic, front: smooth, housing: textured |
| Colour | Front: RAL 9005, housing: RAL 7035 |
| Scope of delivery | Sensor, mounting plate, including fastening material, analogue differential pressure sensor |
| Connection to CAN bus | Direct |
| Interfaces | 2 x RJ45 CAN-bus |
| Number of participants per IoT interface (max.) | 32 |
| Number of participants PU compact (max.) | 4 |
| Number of participants PU (max.) | 32 |
| Number of PDU participants (max.) | 16 |
| Measuring method | Differential pressure measurement |
| Width | 110 mm |
| Height | 30 mm |
| Depth | 40 mm |
| Operating temperature range | 0 °C...55 °C |
| Humidity (non-condensing) | 5...95 % |
| PCF/VE (Cradle-to-Gate) | 1.6 kg CO2 eq (Cat B) |
| Note on PCF class | Category B: PCF value (Cradle-to-Gate) approximately calculated based on product weight and self-declared |
Questions & answers
What is the delivery time of Rittal 7030150 Monitoring system CMC III analog differential pressure sensor?
The article Rittal 7030150 Monitoring system CMC III analog differential pressure sensor is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Rittal 7030150 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Rittal 7030150 Monitoring system CMC III analog differential pressure sensor always at the best possible price. We can give you a discount of 2% on Rittal 7030150 Monitoring system CMC III analog differential pressure sensor if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
This product is recommended as accessory for
|
Rittal 7979312 PDU switched, 32A/230V, 1~, 16 x C13 + 2 x C19
The Rittal DK 7979312 is a switched PDU (Power Distribution Unit) for use in IT network and server racks. It serves as an intelligent power distribution unit with integrated energy measurement per ...Lieske Part No.: 1101058 Mfg Part No: 7979312 Type: DK 7979312 |
-9% 1.198,53 EUR 1.316,52 EUR
![]() ≈ £1,003.17 | ≈ $1,317.18
Made to order · Delivery time approx. 5 workdaysinfo_outline
|
|
Rittal 7979539 DK PDU metered plus 32A/3P CEE 12xC13+12xC19
DK PDU metered+, compact basic power distribution including energy measurement per output, with network interface and display, BLT: 44x1695x70 mm, IEC 60 320: 12x C13 + 12x C19Lieske Part No.: 1910670 Mfg Part No: 7979539 Type: DK 7979539 |
2.008,91 EUR 2.094,87 EUR
![]() ≈ £1,681.46 | ≈ $2,207.79
Made to order · Delivery time approx. 5 workdaysinfo_outline
|
Fitting accessory for Rittal 7030150 Monitoring system CMC III analog differential pressure sensor
|
Rittal 7030000 CMC III Processing Units 32 Sensors
The Processing Unit/Compact is the central unit of the CMC III monitoring system. Up to 32/4 external sensors/CAN bus connection units may be connected to the integral sensors. The units may be ...Lieske Part No.: 360022 Mfg Part No: 7030000 Type: DK 7030000 |
704,89 EUR
![]() ≈ £589.99 | ≈ $774.67
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Rittal 7030090 Monitoring system CMC III CAN-Bus cable RJ45 0.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360234 Mfg Part No: 7030090 Type: DK 7030090 |
8,40 EUR
![]() ≈ £7.03 | ≈ $9.23
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360235 Mfg Part No: 7030091 Type: DK 7030091 |
10,01 EUR
![]() ≈ £8.38 | ≈ $11.00
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030092 Monitoring system CMC III CAN-Bus cable RJ45 1.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360238 Mfg Part No: 7030092 Type: DK 7030092 |
-11% 11,62 EUR 13,05 EUR
![]() ≈ £9.73 | ≈ $12.77
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Rittal 7030093 Monitoring system CMC III CAN-Bus connection cable
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360246 Mfg Part No: 7030093 Type: DK 7030093 |
13,23 EUR
![]() ≈ £11.07 | ≈ $14.54
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030094 Monitoring system CMC III CAN-Bus cable RJ45 5.0 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360247 Mfg Part No: 7030094 Type: DK 7030094 |
15,53 EUR
![]() ≈ £13.00 | ≈ $17.07
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030095 Monitoring system CMC III CAN-Bus cable RJ45 10.0 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 962294 Mfg Part No: 7030095 Type: DK 7030095 |
26,22 EUR
![]() ≈ £21.95 | ≈ $28.82
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979202 PDU Metered 16A/1P IEC-C20 6xC13 (48,3 cm ( 19 inch ))
The Rittal DK 7979202 is a 48,3 cm ( 19 inch ) power distribution unit (PDU) with integrated energy measurement, specifically designed for use in IT network and server racks. It enables precise ...Lieske Part No.: 1980388 Mfg Part No: 7979202 Type: DK 7979202 |
657,92 EUR
![]() ≈ £550.68 | ≈ $723.05
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
Altenative Products for Rittal 7030150 Monitoring system CMC III analog differential pressure sensor
|
Rittal 7010150 Differential pressure sensor DK W x H x D: 110x30x40 mm housing: RAL 7035
The Rittal differential pressure sensor, type DK 7010.150, is a specialised sensor for monitoring the physical environment in enclosures, rooms and containers in IT, industrial and building technology ...Lieske Part No.: 1028162 Mfg Part No: 7010150 |
259,23 EUR
![]() ≈ £216.98 | ≈ $284.89
Made to order · Delivery time approx. 5 workdaysinfo_outline
|