APC AP8959EU3 PDU Switched ZeroU 16A
|
1.320,58 EUR |
|
|
( 1.571,49 EUR incl. VAT ) ≈ £1,100.04 | ≈ $1,448.68 plus delivery charges: 55,00 € |
|
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 168504 |
| Mfg Part No: | AP8959EU3 |
| UPC/EAN: | 0731304277149 |
| Weight: | 0.2 kg |
Product information for APC AP8959EU3:
Applications
This PDU is designed for use in data centres, server racks, and IT infrastructures where controlled and monitorable power distribution is required. It is particularly suitable for environments where avoiding power surges, overloads, and unauthorized access to power outlets is prioritized. The Switched function enables individual control of each outlet, allowing systems to be selectively turned on, off, or rebooted — for example, for troubleshooting or restoring failed devices.
Functions and Features in Detail
The APC AP8959EU3 provides power monitoring at the rack level, enabling real-time tracking of total power consumption. This helps proactively avoid overloads. Users can define alarm threshold values, which trigger visual warnings and network notifications when exceeded. The power delay function allows setting time intervals for turning outlets on and off, preventing power surges and ensuring the correct startup sequence of dependent systems. Network management functions enable remote control and monitoring via Web, SNMP, or Telnet interfaces, allowing remote management of IT infrastructures.
Technology Explained Simply
The PDU is designed as a measurement device, meaning it captures and displays power consumption values. The Switched function allows individual control of outlets, enabling targeted control of power supply to individual devices. The IEC 309 16A 2P+E connection at the input is a standardized industrial plug, designed for higher current loads. The C13 and C19 outlets are common standards in IT and server technology. The 3 m long input cable provides sufficient flexibility for placement within the rack. The operating temperature range of -5 to 45 °C and storage temperature range of -25 to 65 °C make the device suitable for typical IT environments.
Compatibility and Accessories
The PDU is designed for use with standard IT and network devices equipped with C13 or C19 connectors. Network management functions are compatible with common monitoring and management platforms, such as APC InfraStruxure Central, Capacity Manager, and Change Manager. Control is via standardized protocols like SNMP, Telnet, and Web interfaces, facilitating integration into existing IT management systems.
Installation and Mounting
The PDU is a 0U device and can be mounted horizontally or vertically. Mounting is done using fastening elements suitable for the specific installation situation. The 3 m cable length allows flexible placement within the rack, with the input cable connected directly to a mains power source. Installation requires no special tools, as tool-free mounting is possible.
Operational Advantages
The APC AP8959EU3 offers high control over rack power supply. Individual outlet control enables targeted recovery of failed systems and reduces downtime. Power monitoring and alarm functions help detect and prevent overloads early. Remote control via network protocols enables efficient management of IT infrastructures, even from a distance. The combination of Switched function, power measurement, and network management makes this PDU a powerful solution for professional IT environments.
Certification and Operating Conditions
The PDU meets certifications cUL, UL, VDE, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, PSE, VCCI A, ensuring safety and compatibility in various markets. Operating conditions include a temperature range of -5 to 45 °C and relative humidity of 5 to 95 %, making the device suitable for typical IT rooms. Storage temperature is -25 to 65 °C, and storage humidity is also 5 to 95 %.
Color and Design
The device is finished in black, allowing it to blend visually into IT racks. Its compact form factor, with a height of 1791 mm, width of 56 mm, and depth of 46 mm, enables space-saving installation. The weight is 5.73 kg, ensuring stable mounting.
Network Management and Control
Control is via a Web interface, SNMP, or Telnet, enabling integration into existing network management systems. Users can individually control outlets, monitor power consumption values, and configure alarms. Remote control enables efficient management of IT systems, even from a distance.
Power Delay and Sequence
The function to define delay times for turning outlets on and off enables control of device startup sequence. This prevents power surges that may occur when multiple devices are powered on simultaneously, and ensures dependent systems start up in the correct order.
Monitoring and Alarms
Power monitoring is performed in real time, and total consumption is displayed. Users can define threshold values for power consumption, triggering visual warnings and network notifications when exceeded. This enables proactive avoidance of overloads and system failures.
| Certificates | |
| Certification | cUL, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, PSE, UL, VCCI A, VDE |
| Design | |
| PDU types | Metered, Switched |
| Rack capacity | 0U |
| Product colour | Black |
| Features | |
| Cable length | 3 m |
| Operational conditions | |
| Operating temperature (T-T) | -5 - 45 °C |
| Storage temperature (T-T) | -25 - 65 °C |
| Operating relative humidity (H-H) | 5 - 95% |
| Storage relative humidity (H-H) | 5 - 95% |
| Packaging data | |
| Package weight | 8.59 kg |
| Package width | 165 mm |
| Package depth | 114 mm |
| Package height | 2002 mm |
| Ports & interfaces | |
| AC outlets quantity | 24 AC outlet(s) |
| Input connection type | IEC 309 16A 2P+E |
| Output connections | (21) IEC 320 C13, (3) IEC 320 C19 |
| Power | |
| AC input frequency | 50 - 60 Hz |
| Nominal output voltage | 230 V |
| Maximum input current per phase | 16 A |
| Maximum total current draw per phase | 16 A |
| Weight & dimensions | |
| Width | 56 mm |
| Depth | 46 mm |
| Height | 1791 mm |
| Weight | 5.73 kg |
Questions & answers
What is the delivery time of APC AP8959EU3 PDU Switched ZeroU 16A ?
The article APC AP8959EU3 PDU Switched ZeroU 16A is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of APC AP8959EU3 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you APC AP8959EU3 PDU Switched ZeroU 16A always at the best possible price. We can give you a discount of 2% on APC AP8959EU3 PDU Switched ZeroU 16A if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.