| Certificates |
| Certification | cUL, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, PSE, UL, VCCI A, VDE |
| Design |
| PDU types | Metered, Switched |
| Rack capacity | 0U |
| Product colour | Black |
| Features |
| Cable length | 3 m |
| Operational conditions |
| Operating temperature (T-T) | -5 - 45 °C |
| Storage temperature (T-T) | -25 - 65 °C |
| Operating relative humidity (H-H) | 5 - 95% |
| Storage relative humidity (H-H) | 5 - 95% |
| Packaging data |
| Package weight | 8.59 kg |
| Package width | 165 mm |
| Package depth | 114 mm |
| Package height | 2002 mm |
| Ports & interfaces |
| AC outlets quantity | 24 AC outlet(s) |
| Input connection type | IEC 309 16A 2P+E |
| Output connections | (21) IEC 320 C13, (3) IEC 320 C19 |
| Power |
| AC input frequency | 50 - 60 Hz |
| Nominal output voltage | 230 V |
| Maximum input current per phase | 16 A |
| Maximum total current draw per phase | 16 A |
| Weight & dimensions |
| Width | 56 mm |
| Depth | 46 mm |
| Height | 1791 mm |
| Weight | 5.73 kg |
The APC AP8959EU3 is a
Switched Rack Power Distribution Unit (PDU), designed for central power distribution in IT racks. As a
0U device, it is compact and can be mounted horizontally or vertically without occupying rack space. The unit features
24 AC outlets, divided into
21 IEC 320 C13 and
3 IEC 320 C19 connectors, enabling flexible connection of various IT and network devices. Power supply is via an
IEC 309 16A 2P+E input, delivering a nominal output voltage of
230 V at a frequency of
50–60 Hz. The maximum current draw per phase is
16 A, enabling a total power capacity of up to 3.68 kW. The input cable length is
3 m, allowing flexible placement within the rack.
Applications
This PDU is designed for use in data centres, server racks, and IT infrastructures where controlled and monitorable power distribution is required. It is particularly suitable for environments where avoiding power surges, overloads, and unauthorized access to power outlets is prioritized. The
Switched function enables individual control of each outlet, allowing systems to be selectively turned on, off, or rebooted — for example, for troubleshooting or restoring failed devices.
Functions and Features in Detail
The APC AP8959EU3 provides
power monitoring at the rack level, enabling real-time tracking of total power consumption. This helps proactively avoid overloads. Users can
define alarm threshold values, which trigger visual warnings and network notifications when exceeded. The
power delay function allows setting time intervals for turning outlets on and off, preventing power surges and ensuring the correct startup sequence of dependent systems.
Network management functions enable remote control and monitoring via Web, SNMP, or Telnet interfaces, allowing remote management of IT infrastructures.
Technology Explained Simply
The PDU is designed as a
measurement device, meaning it captures and displays power consumption values. The
Switched function allows individual control of outlets, enabling targeted control of power supply to individual devices. The
IEC 309 16A 2P+E connection at the input is a standardized industrial plug, designed for higher current loads. The
C13 and
C19 outlets are common standards in IT and server technology. The
3 m long input cable provides sufficient flexibility for placement within the rack. The operating temperature range of
-5 to 45 °C and storage temperature range of
-25 to 65 °C make the device suitable for typical IT environments.
Compatibility and Accessories
The PDU is designed for use with standard IT and network devices equipped with C13 or C19 connectors. Network management functions are compatible with common monitoring and management platforms, such as APC InfraStruxure Central, Capacity Manager, and Change Manager. Control is via standardized protocols like SNMP, Telnet, and Web interfaces, facilitating integration into existing IT management systems.
Installation and Mounting
The PDU is a
0U device and can be mounted horizontally or vertically. Mounting is done using fastening elements suitable for the specific installation situation. The 3 m cable length allows flexible placement within the rack, with the input cable connected directly to a mains power source. Installation requires no special tools, as tool-free mounting is possible.
Operational Advantages
The APC AP8959EU3 offers high control over rack power supply. Individual outlet control enables targeted recovery of failed systems and reduces downtime. Power monitoring and alarm functions help detect and prevent overloads early. Remote control via network protocols enables efficient management of IT infrastructures, even from a distance. The combination of
Switched function,
power measurement, and
network management makes this PDU a powerful solution for professional IT environments.
Certification and Operating Conditions
The PDU meets certifications
cUL, UL, VDE, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, PSE, VCCI A, ensuring safety and compatibility in various markets. Operating conditions include a temperature range of
-5 to 45 °C and relative humidity of
5 to 95 %, making the device suitable for typical IT rooms. Storage temperature is
-25 to 65 °C, and storage humidity is also
5 to 95 %.
Color and Design
The device is finished in
black, allowing it to blend visually into IT racks. Its compact form factor, with a height of
1791 mm, width of
56 mm, and depth of
46 mm, enables space-saving installation. The weight is
5.73 kg, ensuring stable mounting.
Network Management and Control
Control is via a Web interface, SNMP, or Telnet, enabling integration into existing network management systems. Users can individually control outlets, monitor power consumption values, and configure alarms. Remote control enables efficient management of IT systems, even from a distance.
Power Delay and Sequence
The function to define delay times for turning outlets on and off enables control of device startup sequence. This prevents power surges that may occur when multiple devices are powered on simultaneously, and ensures dependent systems start up in the correct order.
Monitoring and Alarms
Power monitoring is performed in real time, and total consumption is displayed. Users can define threshold values for power consumption, triggering visual warnings and network notifications when exceeded. This enables proactive avoidance of overloads and system failures.