Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English
Xaver Bechtold Logo

Xaver Bechtold 30130706 NHXMH-J 5x25 mm² sheathed cable halogen-free without FE Dca, s2, d2, a1

Your rating:
Average rating
product review for Xaver Bechtold 30130706 NHXMH-J 5x25 mm² sheathed cable halogen-free without FE Dca, s2, d2, a1
( 4.4 / 5 ) 22 ratings
Xaver Bechtold 30130706
This image may differ from the desired article.
35,73 EUR
incl. 12,74 EUR copper surcharge
( 42,52 EUR incl. VAT )
≈ £29.91  |  ≈ $39.27
plus delivery charges: 55,00 €
Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline
In Stock: >1000 meters
1x Xaver Bechtold 30130706 NHXMH-J 5x25 mm² sheathed cable halogen-free without FE Dca, s2, d2, a1
Lieske Part No.:932333
Mfg Part No: 30130706
Weight:1.932 kg
Type:NHXMH-J 5X25
Graduated prices net
From piecesPrice per meters
1532,97 EUR
3030,21 EUR
7027,45 EUR
10024,69 EUR

Product information for Xaver Bechtold 30130706:

The NHXMH-J 5X25 cable from Xaver Bechtold is a halogen-free sheathed cable designed for use in buildings with high personnel and/or asset concentration. It is suitable for installation over, on, in, and under plaster, in dry, damp, and wet rooms, as well as in masonry and concrete. Direct embedding in vibrated, compacted, or poured concrete is excluded. The cable is also suitable for outdoor use, provided environmental conditions remain within the specified temperature limits. The construction ensures minimal smoke development in case of fire and prevents the release of corrosive and toxic gases, thereby enhancing safety during a fire.

Applications
This cable is intended for use in residential and commercial buildings, office buildings, hospitals, schools, and other facilities with high visitor traffic or valuable equipment. The halogen-free design makes it particularly suitable for rooms where fire development and smoke production must be minimized. Outdoor installation is possible as long as ambient temperature remains within the permitted range. The cable can be installed in concrete and masonry structures, but not in freshly placed, vibrated, or compacted concrete.

Functions and Equipment in Detail
The cable consists of copper conductors according to VDE 0295, which are either solid round or stranded. The core insulation is made of a cross-linked polyethylene mixture, providing high mechanical and thermal stability. Core identification follows VDE 0293-308, enabling clear identification of individual cores. A halogen-free and flame-retardant filler sheath provides additional stability and fire protection. The outer sheath is made of a halogen-free polymer mixture, also flame-retardant, and has a gray color (RAL 7001). This color is standard for electrical cables in buildings and allows seamless integration into the environment.

Technology Explained Simply
The rated voltage is 300/500 V, indicating the maximum voltage the cable can safely transmit. The test voltage of 2000 V is used for quality assurance and ensures the insulation remains intact under increased electrical stress. The maximum operating temperature is +70 °C, with the cable tolerating temperatures from +5 °C to +60 °C during installation. After installation, it can be exposed to temperatures from -20 °C to +70 °C. The minimum bending radius is 4 times the cable diameter, allowing safe bending without damaging the conductor or insulation. Thus, the cable is suitable for a wide range of installation scenarios requiring bends and routing in confined spaces.

Compatibility and Accessories
The cable is designed for use in electrical installations complying with standards VDE 0472 and IEC 60332-3-24. Testing includes flammability according to VDE 0472 T. 804 (test type C, equivalent to IEC 332-1), corrosivity of combustion gases according to VDE 0472 T. 813, smoke density according to VDE 0472 T. 816 (test type C, equivalent to IEC 1034-1), halogen-free properties according to VDE 0472 T. 815, and ozone resistance according to VDE 0472 T. 805. Flame retardancy is tested according to VDE 0482-266-2-4 and IEC 60332-3-24. These tests ensure the cable meets requirements for safety, fire protection, and environmental compatibility.

Installation and Mounting
Installation must consider specified temperature and bending radius limits. The cable can be installed in various methods, including in plaster, masonry, concrete (not in fresh concrete), and outdoors. Outdoor installation requires careful planning of environmental conditions, especially temperature. The cable is intended for use in buildings with high personnel and/or asset concentration, so installation must comply with applicable regulations and standards. Appropriate tools and mounting methods are required to ensure cable integrity.

Operational Advantages
The halogen-free design offers significant advantages in case of fire: no toxic or corrosive gases are released, which could damage airways or electrical equipment. Minimal smoke development improves visibility and facilitates evacuation. Flame-retardant properties prevent fire spread along the cable. High mechanical stability and a wide temperature range enable flexible use in various environments. The cable is therefore particularly suitable for applications where safety and reliability are paramount.

General
Nominal voltage300/500 V
Test voltage2000 V
Installation temperature range+5 °C - +60 °C
Temperature range after installation-20 °C - +70 °C
Operation temperature+70 °C
Bending radius4 x cable diameter min.
ConductorBare copper according to VDE 0295
Wire insulationCross-linked polyethylene mixture
Conductor markingaccording to VDE 0293-308
Filler compoundHalogen-free and flame retardant
Outer sheathHalogen-free and flame-retardant polymer blend
Sheath colourGrey RAL 7001
Burning behaviouraccording to VDE 0472 T. 804, test type C (IEC 332-1)
Corrosivity of fire gasesaccording to VDE 0472 T. 813
Flue gas densityaccording to VDE 0472 T. 816, test type C (IEC 1034-1)
Halogen-freeAccording to VDE 0472 Part 815
Ozone resistanceAccording to VDE 0472 T. 805
Flame retardancyVDE 0482-266-2-4, IEC 60332-3-24


Please note...
For this article, we charge 14,85 EUR for measuring, cutting and re-furling the cable. If you take a whole 100m or 500m cable reel, the charge will of course be dropped.

The final cable weight will be determined before invoicing. The calculation is based on the copper content and any additional weight due to drums, pallets, or outer packaging. Prices are subject to this subsequent calculation.

Please note that for cables, that are not in stock and must be produced, the manufacturer may need an order of a minimum length that can be 5-10km depending on cable type!
This article contains a copper surcharge of 12,74 EUR. This depends on daily copper prices and weight of included copper. You can inquire the copper price via phone under +49 7666 884990

Questions & answers

What is the delivery time of Xaver Bechtold 30130706 NHXMH-J 5x25 mm² sheathed cable halogen-free without FE Dca, s2, d2, a1?

The article Xaver Bechtold 30130706 NHXMH-J 5x25 mm² sheathed cable halogen-free without FE Dca, s2, d2, a1 is currently in stock

According to our experience the article is ready for dispatch within 2 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Xaver Bechtold 30130706 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Xaver Bechtold 30130706 NHXMH-J 5x25 mm² sheathed cable halogen-free without FE Dca, s2, d2, a1 always at the best possible price. We can give you a discount of 2% on Xaver Bechtold 30130706 NHXMH-J 5x25 mm² sheathed cable halogen-free without FE Dca, s2, d2, a1 if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 15 meters of Xaver Bechtold 30130706 NHXMH-J 5x25 mm² sheathed cable halogen-free without FE Dca, s2, d2, a1 we can offer you a price of 32,97 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Xaver Bechtold 30130706 NHXMH-J 5x25 Cable halogen-free
Xaver Bechtold 30130706 NHXMH-J 5x25 mm² sheathed cable halogen-free without FE Dca, s2, d2, a1
35,73 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Xaver Bechtold 30130706 NHXMH-J 5x25 Cable halogen-free
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
4 + 9 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.