Xaver Bechtold 30130706

Xaver Bechtold 30130706 NHXMH-J 5x25 Cable halogen-free

Cables > Halogen-free cables and wires > Halogen-free cable NHMH / NHXMH

Xaver Bechtold 30130706 NHXMH-J 5x25 Cable halogen-free

Lieske Part No. 932333
Mfg Part No 30130706
EAN-Code
Manufacturer Xaver Bechtold
Here only 35,73 EUR
42,52 EUR incl. VAT

Further information for Xaver Bechtold 30130706 NHXMH-J 5x25 Cable halogen-free

General
Nominal voltage300/500 V
Test voltage2000 V
Installation temperature range+5 °C - +60 °C
Temperature range after installation-20 °C - +70 °C
Operation temperature+70 °C
Bending radius4 x cable diameter min.
ConductorBare copper according to VDE 0295
Wire insulationCross-linked polyethylene mixture
Conductor markingaccording to VDE 0293-308
Filler compoundHalogen-free and flame retardant
Outer sheathHalogen-free and flame-retardant polymer blend
Sheath colourGrey RAL 7001
Burning behaviouraccording to VDE 0472 T. 804, test type C (IEC 332-1)
Corrosivity of fire gasesaccording to VDE 0472 T. 813
Flue gas densityaccording to VDE 0472 T. 816, test type C (IEC 1034-1)
Halogen-freeAccording to VDE 0472 Part 815
Ozone resistanceAccording to VDE 0472 T. 805
Flame retardancyVDE 0482-266-2-4, IEC 60332-3-24
The NHXMH-J 5X25 cable from Xaver Bechtold is a halogen-free sheathed cable designed for use in buildings with high personnel and/or asset concentration. It is suitable for installation over, on, in, and under plaster, in dry, damp, and wet rooms, as well as in masonry and concrete. Direct embedding in vibrated, compacted, or poured concrete is excluded. The cable is also suitable for outdoor use, provided environmental conditions remain within the specified temperature limits. The construction ensures minimal smoke development in case of fire and prevents the release of corrosive and toxic gases, thereby enhancing safety during a fire.

Applications
This cable is intended for use in residential and commercial buildings, office buildings, hospitals, schools, and other facilities with high visitor traffic or valuable equipment. The halogen-free design makes it particularly suitable for rooms where fire development and smoke production must be minimized. Outdoor installation is possible as long as ambient temperature remains within the permitted range. The cable can be installed in concrete and masonry structures, but not in freshly placed, vibrated, or compacted concrete.

Functions and Equipment in Detail
The cable consists of copper conductors according to VDE 0295, which are either solid round or stranded. The core insulation is made of a cross-linked polyethylene mixture, providing high mechanical and thermal stability. Core identification follows VDE 0293-308, enabling clear identification of individual cores. A halogen-free and flame-retardant filler sheath provides additional stability and fire protection. The outer sheath is made of a halogen-free polymer mixture, also flame-retardant, and has a gray color (RAL 7001). This color is standard for electrical cables in buildings and allows seamless integration into the environment.

Technology Explained Simply
The rated voltage is 300/500 V, indicating the maximum voltage the cable can safely transmit. The test voltage of 2000 V is used for quality assurance and ensures the insulation remains intact under increased electrical stress. The maximum operating temperature is +70 °C, with the cable tolerating temperatures from +5 °C to +60 °C during installation. After installation, it can be exposed to temperatures from -20 °C to +70 °C. The minimum bending radius is 4 times the cable diameter, allowing safe bending without damaging the conductor or insulation. Thus, the cable is suitable for a wide range of installation scenarios requiring bends and routing in confined spaces.

Compatibility and Accessories
The cable is designed for use in electrical installations complying with standards VDE 0472 and IEC 60332-3-24. Testing includes flammability according to VDE 0472 T. 804 (test type C, equivalent to IEC 332-1), corrosivity of combustion gases according to VDE 0472 T. 813, smoke density according to VDE 0472 T. 816 (test type C, equivalent to IEC 1034-1), halogen-free properties according to VDE 0472 T. 815, and ozone resistance according to VDE 0472 T. 805. Flame retardancy is tested according to VDE 0482-266-2-4 and IEC 60332-3-24. These tests ensure the cable meets requirements for safety, fire protection, and environmental compatibility.

Installation and Mounting
Installation must consider specified temperature and bending radius limits. The cable can be installed in various methods, including in plaster, masonry, concrete (not in fresh concrete), and outdoors. Outdoor installation requires careful planning of environmental conditions, especially temperature. The cable is intended for use in buildings with high personnel and/or asset concentration, so installation must comply with applicable regulations and standards. Appropriate tools and mounting methods are required to ensure cable integrity.

Operational Advantages
The halogen-free design offers significant advantages in case of fire: no toxic or corrosive gases are released, which could damage airways or electrical equipment. Minimal smoke development improves visibility and facilitates evacuation. Flame-retardant properties prevent fire spread along the cable. High mechanical stability and a wide temperature range enable flexible use in various environments. The cable is therefore particularly suitable for applications where safety and reliability are paramount.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/932333
qrcode für Xaver Bechtold 30130706 NHXMH-J 5x25 Cable halogen-free