Schneider Electric LC1SKGC200P7 Contactor LC1-SKGC200P7 230 VAC
|
44,91 EUR |
|||||||||||
|
incl. 1,35 EUR copper surcharge ( 53,44 EUR incl. VAT ) ≈ £37.59 | ≈ $49.36 plus delivery charges: 55,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline | |||||||||||
| In Stock: >10 pieces | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 226385 | ||||||||||
| Mfg Part No: | LC1SKGC200P7 | ||||||||||
| UPC/EAN: | 3389110563061 | ||||||||||
| Weight: | 0.132 kg | ||||||||||
| Type: | LC1SKGC200P7 | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Schneider Electric LC1SKGC200P7:
Applications
This contactor is suitable for applications in industry, infrastructure projects, and building installations where reliable and compact load control is required. It is particularly suited for small to medium-sized motors and resistive loads operated in continuous or intermittent operating cycles. Mounting is done on a rail, enabling flexible integration into existing control panels. The operating temperature range is between -20 °C and 50 °C, and the device can be used up to an operating altitude of 2,000 m without performance reduction.
Functions and Equipment in Detail
The device features a contact configuration of 2P with 2 normally open contacts (2 S). The mechanical life expectancy is 10 million switching cycles, with a maximum operating rate of 1,200 switching operations per hour. The operating time is 6–8 ms for coil de-energization and NO opening, and 7–14 ms for coil energization and NO closing. The pickup power is 16 VA, and the holding power consumption is 4.2 VA at 50/60 Hz and 20 °C. The heat dissipation of the device is 1.4 W.
Technology Explained Simply
The control circuit voltage of 230 V AC allows for easy integration into existing control systems. The rated insulation voltage is 690 V and complies with international standards such as IEC 60947, VDE 0110, UL 508, and CSA C22.2 No. 14. The conventional thermal current (Ith) is 20 A at 55 °C in free air, describing the thermal load capacity of the device under realistic operating conditions. The rated make capacity and nominal breaking capacity are 50 A and 40 A, respectively, defining the electrical strength during switching operations. The associated fuse is specified as 20 A gI.
Compatibility and Accessories
Overvoltage limiters are available for this contactor, enhancing the reliability of the control circuit. These include the LA4SKC1U (24–250 V DC, diode), LA4SKE1U (110–250 V AC/DC), and LA4SKE1E (varistor). These components can be used for protection against transient voltage spikes, extending the lifespan of the contactor and connected devices.
Mounting and Installation
Mounting is done on a rail, with device dimensions of 27 mm (width) × 56 mm (height) × 55.5 mm (depth). Connections are made via plugs, supporting rigid cables with cross-sections of 1.5 to 6 mm² (plug 1) and 1.5 to 4 mm² (plug 2), and flexible cables with cross-sections of 0.5 to 6 mm² (without cable end) and 0.35 to 2.5 mm² (without cable end), as well as 0.35 to 6 mm² (with cable end) and 0.35 to 1.5 mm² (with cable end). The tightening torque is 0.8 Nm, with mounting using a screwdriver in position No. 1.
Advantages in Operation
The contactor is characterized by a high mechanical life expectancy and robust construction. Its compact design enables efficient space utilization in control enclosures. Certifications according to CB regulation, CE, UKCA, EAC, and cULus, along with compliance with standards EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1, ensure safety and reliability in use. The TC coating complies with IEC 60068 and DIN 50015, ensuring resistance to environmental influences. The protection rating IP2x complies with VDE 0106, providing protection against finger contact and against solid objects larger than 12.5 mm.
| Complementary | |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 230 V AC 50/60 Hz |
| [Ith] conventional free air thermal current | 20 A (at 55 °C) for power circuit |
| Irms rated making capacity | 50 A AC conforming to NF C 63-110; 50 A AC conforming to IEC 60947 |
| Rated breaking capacity | 40 A at |
| [Icw] rated short-time withstand current | 40 A 55 °C for power circuit |
| Associated fuse rating | 20 A gI at |
| Average impedance | 4 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to BS 5424; Power circuit: 690 V conforming to IEC 60947; Power circuit: 690 V conforming to UL 508; Power circuit: 690 V conforming to VDE 0110 group C; Power circuit: 690 V conforming to CSA C22.2 No 14 |
| Mounting support | Rail |
| Standards | EN/IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1 |
| Product certifications | CB Scheme; CE; UKCA; EAC; cULus |
| Connections - terminals | Connector 1 cable(s) 1.5…6 mm²solid; Connector 2 cable(s) 1.5…4 mm²solid; Connector 1 cable(s) 0.5…6 mm²flexible without cable end; Connector 2 cable(s) 0.35…2.5 mm²flexible without cable end; Connector 1 cable(s) 0.35…6 mm²flexible with cable end; Connector 2 cable(s) 0.35…1.5 mm²flexible with cable end |
| Tightening torque | Power circuit: 0.8 N.m - on connector - with screwdriver pozidriv No 1 |
| Operating time | 6...8 ms coil de-energisation and NO opening; 7...14 ms coil energisation and NO closing |
| Mechanical durability | 10 Mcycles |
| Maximum operating rate | 1200 cyc/h |
| Control circuit voltage limits | Operational: 0.85...1.1 Uc at 50/60 Hz (at |
| Inrush power in VA | 16 VA 50/60 Hz (at 20 °C) |
| Hold-in power consumption in VA | 4.2 VA 50/60 Hz (at 20 °C) |
| Heat dissipation | 1.4 W at 50/60 Hz |
| Contractual warranty | |
| Warranty (in months) | 18 |
| Environment | |
| IP degree of protection | IP2X conforming to VDE 0106 |
| Protective treatment | TC conforming to IEC 60068; TC conforming to DIN 50015 |
| Ambient air temperature for operation | -20…50 °C |
| Ambient air temperature for storage | -50…70 °C |
| Operating altitude | 2000 m without derating |
| Height | 56 mm |
| Width | 27 mm |
| Depth | 55.5 mm |
| Net weight | 0.132 kg |
| Logistical informations | |
| Country of origin | CZ |
| Main | |
| Range | TeSys |
| Product name | TeSys SK |
| Product or component type | Mini contactor |
| Device short name | LC1SKGC |
| Contactor application | Resistive load; Motor control |
| Utilisation category | AC-1; AC-3 |
| power pole contact composition | 2P |
| Pole contact composition | 2 NO |
| [Ie] rated operational current | 5 A at |
| [Ue] rated operational voltage | Power circuit: 690 V AC 50/60 Hz |
| Packing Units | |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.400 cm |
| Package 1 Width | 6.000 cm |
| Package 1 Length | 7.000 cm |
| Package 1 Weight | 127.000 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 40 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 15.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.257 kg |
Questions & answers
What is the delivery time of Schneider Electric LC1SKGC200P7 Contactor LC1-SKGC200P7 230 VAC?
The article Schneider Electric LC1SKGC200P7 Contactor LC1-SKGC200P7 230 VAC is currently in stock
According to our experience the article is ready for dispatch within 2 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Schneider Electric LC1SKGC200P7 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Schneider Electric LC1SKGC200P7 Contactor LC1-SKGC200P7 230 VAC always at the best possible price. We can give you a discount of 2% on Schneider Electric LC1SKGC200P7 Contactor LC1-SKGC200P7 230 VAC if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 10 pieces of Schneider Electric LC1SKGC200P7 Contactor LC1-SKGC200P7 230 VAC we can offer you a price of 43,93 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
This product is recommended as accessory for
|
Schneider Electric LA4SKE1E overvoltage limiter varistor
Mini contactors 0.06 - 5.5 kW TeSys K offers you a complete range of mini contactors with an optimal ratio of performance to compactness and seamless integration into your applications.Lieske Part No.: 478157 Mfg Part No: LA4SKE1E |
188,57 EUR 196,52 EUR
![]() ≈ £157.83 | ≈ $207.24
Made to order · Delivery time approx. 7 workdaysinfo_outline
|
|
Schneider Electric LA4SKE1U overvoltage limiter 110-250 V AC/DC
The product LA4SKE1U from Schneider Electric is an interference suppressor module of the TeSys series, specifically designed as a Varistor mounting module. It is used for suppressing overvoltages in ...Lieske Part No.: 773299 Mfg Part No: LA4SKE1U |
202,35 EUR 210,87 EUR
![]() ≈ £169.37 | ≈ $222.38
Made to order · Delivery time approx. 7 workdaysinfo_outline
|
|
Schneider Electric LA4SKC1U overvoltage limiter 24-250 VDC diode
Mini contactors 0.06 - 5.5 kW TeSys K offers you a complete range of mini contactors with an optimal ratio of performance to compactness and seamless integration into your applications.Lieske Part No.: 799222 Mfg Part No: LA4SKC1U |
188,57 EUR 196,52 EUR
![]() ≈ £157.83 | ≈ $207.24
Made to order · Delivery time approx. 7 workdaysinfo_outline
|
Fitting accessory for Schneider Electric LC1SKGC200P7 Contactor LC1-SKGC200P7 230 VAC
|
Schneider Electric LA4SKE1E overvoltage limiter varistor
Mini contactors 0.06 - 5.5 kW TeSys K offers you a complete range of mini contactors with an optimal ratio of performance to compactness and seamless integration into your applications.Lieske Part No.: 478157 Mfg Part No: LA4SKE1E |
188,57 EUR 196,52 EUR
![]() ≈ £157.83 | ≈ $207.24
Made to order · Delivery time approx. 7 workdaysinfo_outline
|
|
Schneider Electric LA4SKE1U overvoltage limiter 110-250 V AC/DC
The product LA4SKE1U from Schneider Electric is an interference suppressor module of the TeSys series, specifically designed as a Varistor mounting module. It is used for suppressing overvoltages in ...Lieske Part No.: 773299 Mfg Part No: LA4SKE1U |
202,35 EUR 210,87 EUR
![]() ≈ £169.37 | ≈ $222.38
Made to order · Delivery time approx. 7 workdaysinfo_outline
|
|
Schneider Electric LA4SKC1U overvoltage limiter 24-250 VDC diode
Mini contactors 0.06 - 5.5 kW TeSys K offers you a complete range of mini contactors with an optimal ratio of performance to compactness and seamless integration into your applications.Lieske Part No.: 799222 Mfg Part No: LA4SKC1U |
188,57 EUR 196,52 EUR
![]() ≈ £157.83 | ≈ $207.24
Made to order · Delivery time approx. 7 workdaysinfo_outline
|