Applications
The PDU is designed for use in IT infrastructures, particularly in server and network racks, where precise energy management and monitoring are required. It is suitable for racks with a minimum length of 1,800 mm, both with VX IT rack frames and 48,3 cm ( 19 inch ) profile rails. Vertical mounting enables efficient use of the rack space without requiring additional U-space. The phase color coding (L1=pink, L2=black, L3=white) simplifies assignment and maintenance.
Functions and Equipment in Detail
The PDU features 18 C13 sockets and 12 Combi sockets (C13/C19), providing flexible connection options for various IT devices. The rated operating voltage is 400 V (AC), with a maximum rated current of 16 A, corresponding to a rated power of 11 kW. Power supply is via a CEE connector with a 3 m supply cable. Measurement accuracy is ±1 % (kWh) according to standard EN 62053-21. Each output socket can be individually monitored and controlled, with voltage, current, and power thresholds individually adjustable. The PDU includes a bright TFT display (128x128 pixels, RGB) with backlight and energy-saving mode, showing performance data and basic configuration. The display unit is rotatable by 180° and replaceable. Multicolored LEDs (green/yellow/red) indicate the switching status and thresholds for each output.
Technology Explained Simply
The PDU is equipped with a powerful CPU (ARM Cortex A8) enabling energy management and monitoring. The integrated real-time clock with battery backup (up to 10 years, replaceable) ensures time accuracy even during power failure. An integrated electromagnetic buzzer enables acoustic alarm signaling for critical events. Switching is performed via bistable relays, offering low power consumption and high switching capacity, even for inrush currents up to 300 A. Relay states are retained even during power failure. The PDU supports sequential switching of outputs after power restoration to avoid overloading. A digital input (potential-free contact) and an additional alarm output (changeover contact) extend connection options.
Compatibility and Accessories
The PDU features a CAN-Bus interface (RJ45), allowing up to 16 CMC III environmental sensors to be connected. These sensors enable monitoring of environmental parameters such as temperature and humidity. The PDU supports various protocols, including web server (HTTP, HTTPS, SSL), SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into DCIM software, as well as FTP/SFTP for updates and file transfers. User management includes rights management, LDAP(S)/Radius/Active Directory integration, and Syslog server integration (up to 2 servers). Integrated email alerting for alarms (SMTP) is also available. The fully redundant Ethernet interface (10/100/1000 Mbit/s) ensures stable network connectivity. A USB 2.0 port (USB-A) is provided for mass configuration, firmware updates, and data logging.
Mounting and Installation
Mounting is tool-free in the Zero-U-Space of Rittal VX IT or TS IT racks. The delivery includes the necessary mounting hardware. The PDU is designed for vertical mounting and fits in racks with a minimum length of 1,800 mm. The supply cable is 3 m long, allowing flexible positioning. Phase color coding facilitates correct installation.
Operational Advantages
The PDU offers high operational reliability through redundant power supply and integrated fault detection. Precise energy measurement and monitoring per output socket enable efficient energy management and early detection of anomalies. The integrated real-time clock and storage of relay states ensure continuity even during power failure. Support for numerous protocols and interfaces simplifies integration into existing IT infrastructures and DCIM systems. Tool-free mounting and compact design optimize rack space usage. The PDU is designed for operating temperatures from 5 °C to 50 °C and humidity levels from 10 % to 95 % (non-condensing). The storage temperature range is -20 °C to 70 °C. Compliance with standards EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, and EN 62053-21, as well as directives EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, ensures safety and conformity.
| General | |
| Model | PDU, managed |
| Material | Aluminium profile, black anodised, mounting slots: plastic |
| Scope of delivery | Including mounting hardware |
| Options | CMC III CAN-Bus sensors for environmental monitoring connectable, max. 16 sensors |
| Width | 44 mm |
| Depth | 70 mm |
| Length | 1.695 mm |
| Number of sockets and type | 18 x C13 / 12x Combi (C13/C19) |
| Rated operating voltage | 400 V (AC) |
| Rated current (max.) | 16 A |
| Nominal power | 11 kW |
| Power supplies | Number: 1, phases per input: 3~ |
| Connection cable length | 3 m |
| Electrical connection type | CEE |
| Interfaces | USB 2.0 port (USB-A) for mass configuration, firmware update & data logging, CAN-Bus interface (RJ45) for max. 16 environment sensors, serial interface RS232 (RJ12) for LTE unit, scripting, CLI, use of own certificates/TLS 1.2, email sending on alarm (SMTP), user management including rights management, LDAP(S)/Radius/Active Directory integration, Syslog server integration (max. 2 servers), fully redundant Ethernet interface 10/100/1000 Mbit/s |
| Policies | EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU |
| Standards | EN 62368-1, EN 61000-3, EN 61000-4, EN 61000-6, EN 62053-21 |
| Protocols | Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP, TCP/IP v4 & v6, DHCP, DNS, SNMP v1, v2c & v3, Modbus/TCP, OPC-UA, MIB for integration into 3rd party DCIM software, FTP/SFTP (update/file transfer) |
| Operating temperature range | 5 °C...50 °C |
| Humidity (non-condensing) | 10...95 % |
| Storage temperature range | -20 °C...70 °C |
| Suitable for | Housing type: VX IT cabinet frame: ≥ 1,800 mm, housing type: VX IT 19"-profile rails: ≥ 1,800 mm |
Questions & answers
What is the delivery time of Rittal 7979446 DK PDU managed 16A 3-phase 18xC13+12xCombi?
The article Rittal 7979446 DK PDU managed 16A 3-phase 18xC13+12xCombi is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 5 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Rittal 7979446 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Rittal 7979446 DK PDU managed 16A 3-phase 18xC13+12xCombi always at the best possible price. We can give you a discount of 2% on Rittal 7979446 DK PDU managed 16A 3-phase 18xC13+12xCombi if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
Fitting accessory for Rittal 7979446 DK PDU managed 16A 3-phase 18xC13+12xCombi
|
Rittal 7030090 Monitoring system CMC III CAN-Bus cable RJ45 0.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360234 Mfg Part No: 7030090 Type: DK 7030090 |
8,40 EUR
![]() ≈ £7.03 | ≈ $9.23
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030091 Monitoring system CMC III CAN-Bus cable RJ45 1.0 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360235 Mfg Part No: 7030091 Type: DK 7030091 |
10,01 EUR
![]() ≈ £8.38 | ≈ $11.00
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030092 Monitoring system CMC III CAN-Bus cable RJ45 1.5 m
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360238 Mfg Part No: 7030092 Type: DK 7030092 |
-11% 11,62 EUR 13,05 EUR
![]() ≈ £9.73 | ≈ $12.77
Delivery time from supplier's stock (ca.) 9 workdaysinfo_outline
|
|
Rittal 7030093 Monitoring system CMC III CAN-Bus connection cable
This can be used to connect the PU with the CAN bus sensors III, units III, control units III as a bus. Also for cabling together.Applications: For connecting the CAN bus units. Information and power ... Lieske Part No.: 360246 Mfg Part No: 7030093 Type: DK 7030093 |
13,23 EUR
![]() ≈ £11.07 | ≈ $14.54
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955010 Coverings PDU socket strip C13 socket 10 pcs
The DK 7955010 from Rittal is a socket cover for IEC 60 320 C13 sockets, used in PDU socket strips (Power Distribution Units). The product is designed to securely close unused sockets, preventing ...Lieske Part No.: 981045 Mfg Part No: 7955010 Type: DK 7955010 |
132,03 EUR
![]() ≈ £110.51 | ≈ $145.10
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7955015 Coverings PDU socket strip C19 socket 10 pcs
The DK 7955015 socket cover from Rittal is a special accessory designed for use with PDU socket strips (Power Distribution Units). It is intended for the secure closure of open, unused IEC 60 320 C19 ...Lieske Part No.: 981047 Mfg Part No: 7955015 Type: DK 7955015 |
-12% 9,51 EUR 10,82 EUR
![]() ≈ £7.96 | ≈ $10.45
Made to order · Delivery time approx. 5 workdaysinfo_outline
|
|
Rittal 7000688 Mounting adapter PDU TE 8000 2 pcs
The Rittal mounting adapter DK 7000688 is designed for securing a Power Distribution Unit (PDU) to a horizontal system chassis in the VX IT enclosure type. It is specifically designed for integrating ...Lieske Part No.: 999510 Mfg Part No: 7000688 Type: DK 7000688 |
12,88 EUR
![]() ≈ £10.78 | ≈ $14.16
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7979020 PDU universal lock for C14/C20 plugs
The DK 7979020 is a plug lock from the manufacturer Rittal, specifically designed for secure fixation of IEC 60 320 C14 and C20 plugs in PDU- or PSM-modules equipped with C13/C19 sockets. This lock ...Lieske Part No.: 1101023 Mfg Part No: 7979020 Type: DK 7979020 |
26,80 EUR
![]() ≈ £22.43 | ≈ $29.45
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030223 Number code lock for CMC III
The Rittal DK 7030223 is a numeric code lock for access control on enclosure doors, specifically designed for use with the CMC III system. It enables secure and controlled access authorization to ...Lieske Part No.: 1775554 Mfg Part No: 7030223 Type: DK 7030223 |
203,92 EUR
![]() ≈ £170.68 | ≈ $224.11
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030233 VX IT CMC III transponder reader, RAL 9005
The Rittal IT 7030233 is a transponder reader for access control at doors, particularly at VX IT doors and side room doors. It is used for secure release of rack, room, or enclosure doors and is ...Lieske Part No.: 1775580 Mfg Part No: 7030233 Type: IT 7030233 |
337,80 EUR
![]() ≈ £282.74 | ≈ $371.24
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|
|
Rittal 7030611 CMC III online comfort handle VX with Master-Key function
The Rittal IT 7030611 is a CMC III Online comfort handle VX with Master-Key function, specifically developed for use on VX and VX IT enclosures. It provides secure door locking, monitoring of the ...Lieske Part No.: 1775710 Mfg Part No: 7030611 Type: IT 7030611 |
-12% 240,01 EUR 272,99 EUR
![]() ≈ £200.89 | ≈ $263.77
Delivery time from supplier's stock (ca.) 12 workdaysinfo_outline
|