Pepperl+Fuchs 70157025 KFD2-UT2-Ex1 universal temperature transmitter
|
-6% 507,49 EUR 540,62 EUR |
|
|
( 603,91 EUR incl. VAT ) ≈ £424.77 | ≈ $557.73 plus delivery charges: 55,00 € |
|
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |
| Datasheet: | file_download Download |
|---|---|
| Lieske Part No.: | 839781 |
| Mfg Part No: | 70157025 |
| UPC/EAN: | 4050143526529 |
| Weight: | 0.15 kg |
| Type: | KFD2-UT2-Ex1 |
Product information for Pepperl+Fuchs 70157025:
Applications
The KFD2-UT2-Ex1 is used in industrial process environments, particularly in the chemical, petrochemical, and process engineering industries, where secure transmission of temperature data from hazardous zones to the control level is required. It is intended for use in Zone 2 (Div. 2) and Zones 0, 1, 2 (Div. 1, 2), with the exact zone assignment varying depending on installation and environment. The integrated wire fault and sensor break monitoring enables reliable fault detection, signaled via LEDs and a separate fault output.
Functions and Equipment in Detail
The device features a universal input supporting various sensor types: thermocouples of types B, E, J, K, N, R, S, T (IEC 584-1:1995), L (DIN 43710:1985), TXK, TXKH, TXA (P8.585-2001), RTD types such as Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751:1995), Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94), Cu10, Cu50, Cu100 (P50353-92), Ni100 (DIN 43760), potentiometers in the range 0...20 kΩ (2-wire connection) or 0.8...20 kΩ (3-wire connection), and voltage signals in the range -100...100 mV. Measurement is performed with a measurement current of approximately 200 μA for RTD sensors. The maximum line resistance capacity is 50 Ω per line. Calibration deviation is ±(0.06 % of measured value in K + 0.1 % of measurement range + 0.1 K) for Pt100 with 4-wire connection, ±(0.05 % of measured value in °C + 0.1 % of measurement range + 1 K, with 1.2 K for types R and S) for thermocouples, ±(50 μV + 0.1 % of measurement range) for mV signals, and ±(0.05 % of scaling + 0.1 % of measurement range, without considering line errors) for potentiometers.
Technology Explained Simply
The isolation barrier ensures galvanic isolation between the field side (sensor) and the control level to prevent electrical interference and potential ignition sources. The current output is in the range of 0/4 mA to 20 mA, with the output configurable as sink or source. In case of a fault, the signal is set to 0 mA (downscale) or 21.5 mA (upscale) according to NAMUR NE43. The supply voltage is between 20 and 30 V DC, with a maximum power consumption of 0.98 W. Temperature deviation is ±(0.0015 % of measured value in K + 0.006 % of measurement range)/K ΔT amb for Pt100, ±(0.02 K + 0.005 % of measured value in °C + 0.006 % of measurement range)/K ΔT amb for thermocouples, ±(0.01 % of measured value + 0.006 % of measurement range)/K ΔT amb for mV signals, and ±0.006 % of measurement range/K ΔT amb for potentiometers.
Compatibility and Accessories
For internal cold junction compensation (CJC) for thermocouples, the optional accessory K-CJC-** is available. This can be connected to improve measurement accuracy for thermocouples. Configuration is performed via the PACTware software, connected through a programming interface on the device. The devices are designed for mounting in standard 35 mm control panels, with a housing width of 20 mm.
Mounting and Installation
Mounting is in standard control panels with 35 mm width. Connections are made via a removable terminal block. Power is supplied via the Power Rail with 24 V DC. Input and output lines are connected to the corresponding terminals (1–4 for input, 7–9 for output). Configuration is done via PACTware, where parameters such as measurement range, output characteristic, and fault detection settings are adjusted.
Operational Advantages
The KFD2-UT2-Ex1 offers high safety integrity up to SIL 2 according to IEC/EN 61508 and IEC/EN 61511, making it suitable for safety-critical applications. The integrated fault detection ensures reliable signal transmission, with faults signaled via LEDs and a separate fault output. Universal input support allows use with various sensor types, increasing flexibility in application. Configuration via PACTware enables simple and precise adjustment of device parameters.
Safety Integrity Level (SIL)
The device achieves a Safety Integrity Level (SIL) of SIL 2 according to IEC/EN 61508 and IEC/EN 61511, enabling use in safety-critical applications. The functions for wire fault and sensor break monitoring contribute to reliability.
Supply Voltage
The rated voltage is between 20 and 30 V DC, with power supplied via the Power Rail. The maximum power consumption is 0.98 W.
Current Output
The output provides a current signal in the range of 0/4 mA to 20 mA, with the operating mode configurable as sink or source. In case of a fault, the signal is set to 0 mA (downscale) or 21.5 mA (upscale) according to NAMUR NE43.
Input Types
The input supports thermocouples, RTD resistance thermometers, potentiometers, and voltage signals. Measurement is performed with a measurement current of approximately 200 μA for RTD sensors.
Configuration
Configuration is performed via the PACTware software, connected through a programming interface on the device. Parameters such as measurement range, output characteristic, and fault detection settings can be individually adjusted.
Housing Width
The housing width is 20 mm, allowing the device to be mounted in standard 35 mm control panels.
Fault Detection
The integrated wire fault and sensor break monitoring signals faults via LEDs and a separate fault output. Fault detection is performed via loop monitoring for sensor break and short circuit.
Cold Junction Compensation (CJC)
For thermocouples, internal cold junction compensation (CJC) is available, with the optional accessory K-CJC-** used to improve measurement accuracy.
Connection Types
Connections are made via a removable terminal block. Input and output lines are connected to the corresponding terminals (1–4 for input, 7–9 for output).
Approvals and Standards
The device complies with standards IEC/EN 61508 and IEC/EN 61511 for safety integrity up to SIL 2. Approval for use in hazardous areas is for Zone 2 (Div. 2) and Zones 0, 1, 2 (Div. 1, 2).
Power Consumption
The maximum power consumption is 0.98 W, with supply voltage between 20 and 30 V DC.
| General | |
| Number of channels | 1-channel |
| Safety integrity level (SIL) | SIL 2 |
| Rated voltage | 20 ... 30 V DC |
| Power output | 0/4 ... 20 mA |
| Operation mode | sink or source |
| Input types | Thermocouple, RTD, potentiometer, voltage |
| Fault detection | Cable fault and sensor break monitoring |
| Configuration | PACTware |
| Housing width | 20 mm |
| Supply | 24 V DC (Power Rail) |
| Power consumption | ≤ 0,98 W |
| Cold junction compensation (CJC) | internal and external |
| Connection types | 2-wire and 3-wire connection |
| Approval | Zone 2 (Div. 2), Zone 0, 1, 2 (Div. 1, 2) |
| Standards | IEC/EN 61508, IEC/EN 61511 |
| Deviation due to ambient temperature | Pt100: ±(0.0015 % of measured value in K + 0.006 % of measurement range)/K ΔT amb; Thermocouples: ±(0.02 K + 0.005 % of measured value in °C + 0.006 % of measurement range)/K ΔT amb; mV: ±(0.01 % of measured value + 0.006 % of measurement range)/K ΔT amb; Potentiometer: ±0.006 % of measurement range/K ΔT amb |
| Calibration deviation | Pt100: ±(0.06 % of measured value in K + 0.1 % of measurement range + 0.1 K); Thermocouples: ±(0.05 % of measured value in °C + 0.1 % of measurement range + 1 K); mV: ±(50 μV + 0.1 % of measurement range); Potentiometer: ±(0.05 % of scaling + 0.1 % of measurement range) |
| Measurement current (RTD) | ca. 200 μA |
| Maximum cable resistance capacity | 50 Ω per conductor |
| Output characteristic | 0/4 mA ... 20 mA |
| Accessories | K-CJC-** (optional) |
| Programming interface | |
Questions & answers
What is the delivery time of Pepperl+Fuchs 70157025 KFD2-UT2-Ex1 universal temperature transmitter ?
The article Pepperl+Fuchs 70157025 KFD2-UT2-Ex1 universal temperature transmitter is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Pepperl+Fuchs 70157025 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Pepperl+Fuchs 70157025 KFD2-UT2-Ex1 universal temperature transmitter always at the best possible price. We can give you a discount of 2% on Pepperl+Fuchs 70157025 KFD2-UT2-Ex1 universal temperature transmitter if you choose payment in advance on ordering.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.