Further information for Pepperl+Fuchs 70157025 KFD2-UT2-Ex1 temperature transmitter
General
Number of channels
1-channel
Safety integrity level (SIL)
SIL 2
Rated voltage
20 ... 30 V DC
Power output
0/4 ... 20 mA
Operation mode
sink or source
Input types
Thermocouple, RTD, potentiometer, voltage
Fault detection
Cable fault and sensor break monitoring
Configuration
PACTware
Housing width
20 mm
Supply
24 V DC (Power Rail)
Power consumption
≤ 0,98 W
Cold junction compensation (CJC)
internal and external
Connection types
2-wire and 3-wire connection
Approval
Zone 2 (Div. 2), Zone 0, 1, 2 (Div. 1, 2)
Standards
IEC/EN 61508, IEC/EN 61511
Deviation due to ambient temperature
Pt100: ±(0.0015 % of measured value in K + 0.006 % of measurement range)/K ΔT amb; Thermocouples: ±(0.02 K + 0.005 % of measured value in °C + 0.006 % of measurement range)/K ΔT amb; mV: ±(0.01 % of measured value + 0.006 % of measurement range)/K ΔT amb; Potentiometer: ±0.006 % of measurement range/K ΔT amb
Calibration deviation
Pt100: ±(0.06 % of measured value in K + 0.1 % of measurement range + 0.1 K); Thermocouples: ±(0.05 % of measured value in °C + 0.1 % of measurement range + 1 K); mV: ±(50 μV + 0.1 % of measurement range); Potentiometer: ±(0.05 % of scaling + 0.1 % of measurement range)
Measurement current (RTD)
ca. 200 μA
Maximum cable resistance capacity
50 Ω per conductor
Output characteristic
0/4 mA ... 20 mA
Accessories
K-CJC-** (optional)
Programming interface
The KFD2-UT2-Ex1 from Pepperl+Fuchs is a 1-channel isolation barrier temperature transmitter designed for use in safety-critical applications. The device converts signals from temperature sensors such as thermocouples, RTD resistance thermometers, potentiometers, or voltage signals into a standardized current signal in the range of 0/4 mA to 20 mA. It is powered by a 24 V DC supply (Power Rail) and is suitable for use in hazardous areas, with the operating mode configurable as sink or source. Configuration is performed via the PACTware software, allowing individual settings such as measurement range, output characteristic, and fault detection parameters to be adjusted.
Applications
The KFD2-UT2-Ex1 is used in industrial process environments, particularly in the chemical, petrochemical, and process engineering industries, where secure transmission of temperature data from hazardous zones to the control level is required. It is intended for use in Zone 2 (Div. 2) and Zones 0, 1, 2 (Div. 1, 2), with the exact zone assignment varying depending on installation and environment. The integrated wire fault and sensor break monitoring enables reliable fault detection, signaled via LEDs and a separate fault output.
Functions and Equipment in Detail
The device features a universal input supporting various sensor types: thermocouples of types B, E, J, K, N, R, S, T (IEC 584-1:1995), L (DIN 43710:1985), TXK, TXKH, TXA (P8.585-2001), RTD types such as Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751:1995), Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94), Cu10, Cu50, Cu100 (P50353-92), Ni100 (DIN 43760), potentiometers in the range 0...20 kΩ (2-wire connection) or 0.8...20 kΩ (3-wire connection), and voltage signals in the range -100...100 mV. Measurement is performed with a measurement current of approximately 200 μA for RTD sensors. The maximum line resistance capacity is 50 Ω per line. Calibration deviation is ±(0.06 % of measured value in K + 0.1 % of measurement range + 0.1 K) for Pt100 with 4-wire connection, ±(0.05 % of measured value in °C + 0.1 % of measurement range + 1 K, with 1.2 K for types R and S) for thermocouples, ±(50 μV + 0.1 % of measurement range) for mV signals, and ±(0.05 % of scaling + 0.1 % of measurement range, without considering line errors) for potentiometers.
Technology Explained Simply
The isolation barrier ensures galvanic isolation between the field side (sensor) and the control level to prevent electrical interference and potential ignition sources. The current output is in the range of 0/4 mA to 20 mA, with the output configurable as sink or source. In case of a fault, the signal is set to 0 mA (downscale) or 21.5 mA (upscale) according to NAMUR NE43. The supply voltage is between 20 and 30 V DC, with a maximum power consumption of 0.98 W. Temperature deviation is ±(0.0015 % of measured value in K + 0.006 % of measurement range)/K ΔT amb for Pt100, ±(0.02 K + 0.005 % of measured value in °C + 0.006 % of measurement range)/K ΔT amb for thermocouples, ±(0.01 % of measured value + 0.006 % of measurement range)/K ΔT amb for mV signals, and ±0.006 % of measurement range/K ΔT amb for potentiometers.
Compatibility and Accessories
For internal cold junction compensation (CJC) for thermocouples, the optional accessory K-CJC-** is available. This can be connected to improve measurement accuracy for thermocouples. Configuration is performed via the PACTware software, connected through a programming interface on the device. The devices are designed for mounting in standard 35 mm control panels, with a housing width of 20 mm.
Mounting and Installation
Mounting is in standard control panels with 35 mm width. Connections are made via a removable terminal block. Power is supplied via the Power Rail with 24 V DC. Input and output lines are connected to the corresponding terminals (1–4 for input, 7–9 for output). Configuration is done via PACTware, where parameters such as measurement range, output characteristic, and fault detection settings are adjusted.
Operational Advantages
The KFD2-UT2-Ex1 offers high safety integrity up to SIL 2 according to IEC/EN 61508 and IEC/EN 61511, making it suitable for safety-critical applications. The integrated fault detection ensures reliable signal transmission, with faults signaled via LEDs and a separate fault output. Universal input support allows use with various sensor types, increasing flexibility in application. Configuration via PACTware enables simple and precise adjustment of device parameters.
Safety Integrity Level (SIL)
The device achieves a Safety Integrity Level (SIL) of SIL 2 according to IEC/EN 61508 and IEC/EN 61511, enabling use in safety-critical applications. The functions for wire fault and sensor break monitoring contribute to reliability.
Supply Voltage
The rated voltage is between 20 and 30 V DC, with power supplied via the Power Rail. The maximum power consumption is 0.98 W.
Current Output
The output provides a current signal in the range of 0/4 mA to 20 mA, with the operating mode configurable as sink or source. In case of a fault, the signal is set to 0 mA (downscale) or 21.5 mA (upscale) according to NAMUR NE43.
Input Types
The input supports thermocouples, RTD resistance thermometers, potentiometers, and voltage signals. Measurement is performed with a measurement current of approximately 200 μA for RTD sensors.
Configuration
Configuration is performed via the PACTware software, connected through a programming interface on the device. Parameters such as measurement range, output characteristic, and fault detection settings can be individually adjusted.
Housing Width
The housing width is 20 mm, allowing the device to be mounted in standard 35 mm control panels.
Fault Detection
The integrated wire fault and sensor break monitoring signals faults via LEDs and a separate fault output. Fault detection is performed via loop monitoring for sensor break and short circuit.
Cold Junction Compensation (CJC)
For thermocouples, internal cold junction compensation (CJC) is available, with the optional accessory K-CJC-** used to improve measurement accuracy.
Connection Types
Connections are made via a removable terminal block. Input and output lines are connected to the corresponding terminals (1–4 for input, 7–9 for output).
Approvals and Standards
The device complies with standards IEC/EN 61508 and IEC/EN 61511 for safety integrity up to SIL 2. Approval for use in hazardous areas is for Zone 2 (Div. 2) and Zones 0, 1, 2 (Div. 1, 2).
Power Consumption
The maximum power consumption is 0.98 W, with supply voltage between 20 and 30 V DC.