LTC H05V-K 1.0 mm² black 100 m in carton PVC-insulated single-core cable Eca
|
39,38 EUR |
|||||||||||
|
incl. 11,07 EUR copper surcharge ( 46,86 EUR incl. VAT ) ≈ £32.92 | ≈ $43.51 plus delivery charges: 55,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 2 workdaysinfo_outline | |||||||||||
| Sales unit: 100 meters | |||||||||||
| In Stock: >25 meters | |||||||||||
| Lieske Part No.: | 974585 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | |||||||||||
| Weight: | 1.773 kg | ||||||||||
| Type: | H05V-K 1,0 SW | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for LTC H05V-K 1,0 SW:
Applications
This cable is suitable for use in electrical devices, lighting systems, and protected installations within buildings. It is intended for use in doorbell and signaling systems, meaning it is designed for applications with low voltage and low power. Installation takes place in protected areas, for example in conduits, under plaster, or in luminaires, with the ambient temperature during installation ranging between +5 °C and +70 °C. After installation, the cable can be operated at temperatures from -30 °C to +70 °C.
Functions and Features in Detail
The conductor is made of bare, fine-stranded copper, ensuring high flexibility and good electrical conductivity. The PVC insulation provides reliable protection against electrical voltages and is specified according to VDE 0207. The sheath color complies with VDE 0293 standards, ensuring uniform color coding and thus easy identification of the cable during installation. The maximum operating temperature is +70 °C, making the cable suitable for use in indoor environments with normal ambient temperatures.
Technical Explanation
The nominal voltage of 300/500 V means the cable is designed for alternating voltages up to 300 V and direct voltages up to 500 V. The test voltage of 2000 V serves as a safety margin and ensures the insulation remains stable even under increased voltage. The minimum bending radius is 15 times the cable diameter, allowing flexible installation without damaging the conductor. The flame retardancy according to VDE 0472 Part 804, Test Method B (equivalent to IEC 332-1), indicates that the cable is only limitedly flammable and does not propagate live flames, enhancing safety in buildings.
Compatibility and Accessories
The cable is intended for use in doorbell and signaling systems, with installation required in protected areas. It is not intended for use in open, unprotected areas or outdoors. Installation in conduits, under plaster, or in luminaires is permitted, provided ambient conditions do not exceed the specified temperature ranges.
Installation and Mounting
Installation takes place in protected areas, with the cable being routed in conduits, under plaster, or in luminaires. Installation must occur at temperatures between +5 °C and +70 °C to ensure optimal processing and functionality. The minimum bending radius of 15 times the cable diameter must be observed to avoid damaging the copper braid. The cable is intended for use in doorbell and signaling systems, with electrical requirements of these systems to be considered.
Operational Advantages
The flexible PVC insulation and fine-stranded copper conductor enable easy and safe installation. The high test voltage and flame retardancy according to VDE 0472 Part 804, Test Method B, ensure enhanced safety during operation. The cable is designed for indoor use and provides reliable electrical conduction under normal ambient conditions. Adhering to the specified temperature ranges and installation conditions ensures long service life and stable performance.
The item price shown refers to 100 meters LTC H05V-K 1,0 SW
| General | |
| Nominal voltage | 300/500 V |
| Test voltage | 2000 V |
| Installation temperature range | +5 °C - +70 °C |
| Temperature range after installation | -30 °C - +70 °C |
| Operation temperature | +70 °C |
| Bending radius | 15 x cable diameter min. |
| Flame retardancy | According to VDE 0472 T. 804 test type B (IEC 332-1) |
| Conductor | bare copper, fine-stranded |
| Insulation | PVC according to VDE 0207 |
| Sheath colour | in accordance with VDE 0293 |
Questions & answers
What is the delivery time of LTC H05V-K 1.0 mm² black 100 m in carton PVC-insulated single-core cable Eca?
The article LTC H05V-K 1.0 mm² black 100 m in carton PVC-insulated single-core cable Eca is currently in stock
According to our experience the article is ready for dispatch within 2 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of LTC H05V-K 1,0 SW to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you LTC H05V-K 1.0 mm² black 100 m in carton PVC-insulated single-core cable Eca always at the best possible price. We can give you a discount of 2% on LTC H05V-K 1.0 mm² black 100 m in carton PVC-insulated single-core cable Eca if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 10 meters of LTC H05V-K 1.0 mm² black 100 m in carton PVC-insulated single-core cable Eca we can offer you a price of 35,98 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.
How many units does the article contain?
LTC H05V-K 1.0 mm² black 100 m in carton PVC-insulated single-core cable Eca is offered by us in a sales unit of 100 meters If you need a larger quantity, you can contact us at any time. We will make a special offer for you