Eltako 21100102 ESR12NP-230V+UC surge switch relay 1NO non-potential-free
|
61,53 EUR 64,12 EUR |
|||||||||||
|
( 73,22 EUR incl. VAT ) ≈ £51.50 | ≈ $67.62 plus delivery charges: 55,00 € |
|||||||||||
| Delivery time from supplier's stock (ca.) 3 workdaysinfo_outline | |||||||||||
| In Stock: >50 pieces | |||||||||||
| Lieske Part No.: | 662529 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfg Part No: | 21100102 | ||||||||||
| UPC/EAN: | 4010312107928 | ||||||||||
| Weight: | 0.123 kg | ||||||||||
| Type: | ESR12NP-230V+UC | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Eltako 21100102:
Applications
This device is intended for use in electrical installations indoors, particularly in residential and commercial buildings where automated or time-controlled lighting is required. It is suitable for controlling 230V LED lamps up to 600 watts and incandescent lamps up to 2300 watts. The ESV function with delayed reset allows for automatic switching off of lighting after a defined time if no manual off command is issued. This is especially useful in corridors, stairwells, or office rooms to save energy. When used in a circuit with a field release switch FR12-230V, no additional base load is required, provided the monitoring voltage of the release switch is set to max.
Functions and Equipment in Detail
The device features a non-potential-free make contact with a rated switching capacity of 16A/250V AC. The switching function occurs at zero crossing to protect contacts and connected lamps. The control voltage is 230V, supplemented by a galvanically isolated universal control voltage ranging from 8 to 230V (UC), enabling flexible actuation from various control sources. The supply and switching voltage is also 230V. The delayed reset in the ESV function is adjustable via a minute scale from 2 to 120 minutes. Additionally, the options switch-off warning" and "push-button permanent light can be activated. When switch-off warning is enabled, the lighting flickers for 30 seconds before automatic switch-off to allow for manual override. When permanent light is enabled, the device switches to permanent light if a control push-button is pressed for longer than 1 second; permanent light is turned off by pressing the button again for longer than 2 seconds, otherwise it turns off automatically after 2 hours. Combining both functions results in the switch-off warning only occurring after the permanent light has been switched off.
Technology Explained Simply
The hybrid technology of the ESR12NP-230V+UC combines the advantages of electronic control with a mechanical relay. The electronic actuation ensures wear-free switching and precise time control, while the relay handles high switching capacity. Zero-crossing switching minimizes electrical stress and extends the life of contacts and connected lamps. The actuation LED blinks after 15 minutes if a push-button is blocked (not in ER function), indicating a malfunction. Standby power consumption is only 0.5 watts, ensuring energy-efficient operation. In the event of supply voltage failure, the device is switched off in a defined manner to avoid uncontrolled states.
Compatibility and Accessories
The device is suitable for actuation via 230V control sources, with the 230V control input capable of handling neon lamp current up to 150mA, regardless of ignition voltage (not in ER function). It can be used in relay functions for feedback with the switching voltage of a dimmer switch. The galvanically isolated universal control voltage (8–230V UC) allows use with various control sources, including push-buttons, sensors, or other control devices. Compatibility with the field release switch FR12-230V permits use without additional base load, provided the monitoring voltage is set to max.
Mounting and Installation
The device is mounted on a DIN support rail (TH35), with an installation width of 18 mm. Mounting is done by simply snapping it into the rail. The connection terminals are designed for wiring, with exact terminal assignments according to the respective connection diagram. The functions ES, ER, and ESV are selected via an integrated rotary switch. The delayed reset time is adjusted using a minute scale on the device. Installation requires no special tools, but compliance with electrical safety regulations is mandatory.
Operational Advantages
Operation of the ESR12NP-230V+UC is characterized by low switching noise and high reliability. The hybrid technology ensures long service life and minimizes maintenance requirements. The precise adjustability of the delayed reset and the options for switch-off warning and push-button permanent light increase flexibility in use. The low standby power consumption of 0.5 watts contributes to energy efficiency. Galvanic isolation of the control voltage enhances safety and enables flexible integration into existing installations.
| General | |
| Degree of protection | not specified |
| Switching power | 16 A/250V AC |
| Control voltage | 230 V |
| Universal control voltage | 8..230 V |
| Supply voltage | 230 V |
| Switching voltage | 230 V |
| Release-delay | 2 to 120 minutes |
| Stand-by loss | 0,5 W |
| Nebulizer current at 230V input | 150 mA |
| Functions | ES, ER, ESV |
| Push-button constant light | Switchable |
| Pre-warning of switching-off | Switchable |
| Switching noise | very low |
| Built-in width | 18 mm |
| Mounting | DIN-EN 60715 TH35 |
| Contact circuit | At zero crossing |
| Technology | Hybrid technology |
| LED lamp power | 600 W |
| Incandescent lamp power | 2300 W |
| Constant light switch-off time | 2 Hours |
| Shut-off warning duration | 30 Seconds |
| Push-button constant light activation | longer than 1 second |
| Push-button constant light shutdown | longer than 2 seconds |
| Drive control when switch is blocked | LED blinks after 15 minutes |
| Behavior in case of power failure | defined off |
| Compatibility with FR12-230V | no additional base load required, monitoring voltage at maximum |
| Control LED | |
Questions & answers
What is the delivery time of Eltako 21100102 ESR12NP-230V+UC surge switch relay 1NO non-potential-free ?
The article Eltako 21100102 ESR12NP-230V+UC surge switch relay 1NO non-potential-free is currently in stock
According to our experience the article is ready for dispatch within 3 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Eltako 21100102 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Eltako 21100102 ESR12NP-230V+UC surge switch relay 1NO non-potential-free always at the best possible price. We can give you a discount of 2% on Eltako 21100102 ESR12NP-230V+UC surge switch relay 1NO non-potential-free if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 6 pieces of Eltako 21100102 ESR12NP-230V+UC surge switch relay 1NO non-potential-free we can offer you a price of 57,84 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.