Eltako 21100102, EAN: 4010312107928

Eltako 21100102 Surge Relay 1S non-potential-free

Installation > Modular devices / equipment installation > Impulse switch / relay

Eltako 21100102 Surge Relay 1S non-potential-free

Lieske Part No. 662529
Mfg Part No 21100102
EAN-Code 4010312107928
Manufacturer Eltako
Here only 61,53 EUR
73,22 EUR incl. VAT

Further information for Eltako 21100102 Surge Relay 1S non-potential-free

General
Degree of protectionnot specified
Switching power16 A/250V AC
Control voltage230 V
Universal control voltage8..230 V
Supply voltage230 V
Switching voltage230 V
Release-delay2 to 120 minutes
Stand-by loss0,5 W
Nebulizer current at 230V input150 mA
FunctionsES, ER, ESV
Push-button constant lightSwitchable
Pre-warning of switching-offSwitchable
Switching noisevery low
Built-in width18 mm
MountingDIN-EN 60715 TH35
Contact circuitAt zero crossing
TechnologyHybrid technology
LED lamp power600 W
Incandescent lamp power2300 W
Constant light switch-off time2 Hours
Shut-off warning duration30 Seconds
Push-button constant light activationlonger than 1 second
Push-button constant light shutdownlonger than 2 seconds
Drive control when switch is blockedLED blinks after 15 minutes
Behavior in case of power failuredefined off
Compatibility with FR12-230Vno additional base load required, monitoring voltage at maximum
Control LEDYes
The Eltako ESR12NP-230V+UC is a modular device in the category of power surge switches / relays, specifically designed for mounting on a support rail according to DIN-EN 60715 TH35. It features an installation width of 18 mm (1 module unit) and a depth of 58 mm. The device is used for electronic control of lighting systems and other consumers in a 230V network, enabling switching between functions of power surge switch, switching relay, and power surge switch with delayed reset (ES, ER, ESV) via an integrated rotary switch. The hybrid technology combines wear-free electronic actuation with a special relay to ensure high switching capacity and long service life.

Applications
This device is intended for use in electrical installations indoors, particularly in residential and commercial buildings where automated or time-controlled lighting is required. It is suitable for controlling 230V LED lamps up to 600 watts and incandescent lamps up to 2300 watts. The ESV function with delayed reset allows for automatic switching off of lighting after a defined time if no manual off command is issued. This is especially useful in corridors, stairwells, or office rooms to save energy. When used in a circuit with a field release switch FR12-230V, no additional base load is required, provided the monitoring voltage of the release switch is set to max.

Functions and Equipment in Detail
The device features a non-potential-free make contact with a rated switching capacity of 16A/250V AC. The switching function occurs at zero crossing to protect contacts and connected lamps. The control voltage is 230V, supplemented by a galvanically isolated universal control voltage ranging from 8 to 230V (UC), enabling flexible actuation from various control sources. The supply and switching voltage is also 230V. The delayed reset in the ESV function is adjustable via a minute scale from 2 to 120 minutes. Additionally, the options switch-off warning" and "push-button permanent light can be activated. When switch-off warning is enabled, the lighting flickers for 30 seconds before automatic switch-off to allow for manual override. When permanent light is enabled, the device switches to permanent light if a control push-button is pressed for longer than 1 second; permanent light is turned off by pressing the button again for longer than 2 seconds, otherwise it turns off automatically after 2 hours. Combining both functions results in the switch-off warning only occurring after the permanent light has been switched off.

Technology Explained Simply
The hybrid technology of the ESR12NP-230V+UC combines the advantages of electronic control with a mechanical relay. The electronic actuation ensures wear-free switching and precise time control, while the relay handles high switching capacity. Zero-crossing switching minimizes electrical stress and extends the life of contacts and connected lamps. The actuation LED blinks after 15 minutes if a push-button is blocked (not in ER function), indicating a malfunction. Standby power consumption is only 0.5 watts, ensuring energy-efficient operation. In the event of supply voltage failure, the device is switched off in a defined manner to avoid uncontrolled states.

Compatibility and Accessories
The device is suitable for actuation via 230V control sources, with the 230V control input capable of handling neon lamp current up to 150mA, regardless of ignition voltage (not in ER function). It can be used in relay functions for feedback with the switching voltage of a dimmer switch. The galvanically isolated universal control voltage (8–230V UC) allows use with various control sources, including push-buttons, sensors, or other control devices. Compatibility with the field release switch FR12-230V permits use without additional base load, provided the monitoring voltage is set to max.

Mounting and Installation
The device is mounted on a DIN support rail (TH35), with an installation width of 18 mm. Mounting is done by simply snapping it into the rail. The connection terminals are designed for wiring, with exact terminal assignments according to the respective connection diagram. The functions ES, ER, and ESV are selected via an integrated rotary switch. The delayed reset time is adjusted using a minute scale on the device. Installation requires no special tools, but compliance with electrical safety regulations is mandatory.

Operational Advantages
Operation of the ESR12NP-230V+UC is characterized by low switching noise and high reliability. The hybrid technology ensures long service life and minimizes maintenance requirements. The precise adjustability of the delayed reset and the options for switch-off warning and push-button permanent light increase flexibility in use. The low standby power consumption of 0.5 watts contributes to energy efficiency. Galvanic isolation of the control voltage enhances safety and enables flexible integration into existing installations.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/662529
qrcode für Eltako 21100102 Surge Relay 1S non-potential-free