Dold 0070149 RN5897.12/300/61 AC/DC85-230V insulation monitor 10k-250k 20k-1M
|
459,13 EUR |
|||||||||||
|
( 546,36 EUR incl. VAT ) ≈ £383.37 | ≈ $503.21 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001683 | ||||||||||
| Mfg Part No: | 0070149 | ||||||||||
| UPC/EAN: | 4030641701499 | ||||||||||
| Weight: | 0.335 kg | ||||||||||
| Type: | RN5897.12/300/61 AC/DC85-230V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0070149:
Applications
The insulation monitor is universally applicable in various application areas, including UPS systems, networks with frequency converters, battery networks, DC drives, hybrid and battery-powered vehicles, as well as mobile power generators. It is designed for network capacitances up to 30 μF and also allows monitoring during de-energized networks, making it particularly suitable for systems with intermittent power supply.
Functions and Equipment in Detail
The device features two independently adjustable trigger thresholds: a pre-alarm threshold ranging from 20 kΩ to 1 MΩ and an alarm threshold from 10 kΩ to 250 kΩ. These settings enable differentiated responses to insulation degradation, with the pre-alarm triggering an early warning before the critical alarm threshold is reached. The output contacts consist of two individual changeover contacts—one for the pre-alarm and one for the alarm—which can be operated in either energized or de-energized mode depending on the application. A multicolored device status LED visualizes the operating state and allows for quick visual inspection of the device.
Technology Explained Simply
Insulation resistance measurement is performed between terminals L(+) and L(-) as well as PE1/PE2. An active test voltage pulse with alternating polarity is used to determine insulation quality. The connection monitoring for the measurement circuit L(+) / L(-) is switchable and generates a fault message if interrupted. The protective earth connection monitoring PE1/PE2 is non-switchable and ensures that a break in the protective conductor is also detected. After switching on the auxiliary voltage (AC/DC 85–230 V), the device performs an internal self-test lasting approximately 12 seconds. Afterward, continuous insulation measurement begins. An external control input (X1/X2) allows connection to a combined test/reset button.
Compatibility and Accessories
The device is designed for IT systems with rated voltages of AC 0–230 V and DC 0–230 V. It is suitable for use in AC, DC, and AC/DC networks. The auxiliary voltage can range from AC/DC 85–230 V, enabling flexible integration into existing power supplies. The width is 52.5 mm, allowing installation in standard installation distributors. Certifications include UL-listed C/US and CCC, enabling use in corresponding markets.
Mounting and Installation
Mounting is done in an installation distributor. Terminals L(+) and L(-) are connected directly to the network to be monitored, while PE1 and PE2 are connected to the protective conductor system via separate conductors. The auxiliary voltage is supplied via A1(+) and A2. The tamper-proof transparent cover protects the device against unauthorized manipulation and ensures safe operation.
Operational Advantages
The insulation monitor provides preventive fire and system protection through early detection of insulation faults. Alarm memory is selectable, so an alarm remains indicated even after the fault is resolved until manually reset. Simple operation via rotary switches and visual indication via the LED simplify maintenance and diagnostics. The device requires no additional pre-stage device, simplifying installation and reducing system costs.
| Technical data | |
| Approvals | UL |
| Classification | For mobile power generators |
| Enclosure design | Distribution board |
| IMD type | AC, AC/DC, DC |
| Nominal voltage IT system | AC 0 - 230 V, DC 0 - 230 V |
| Response value | 10 - 250 kΩ |
| Response value type | Adjustable |
| Width | 52,5 mm |
| Type | RN 5897/300 |
| Earth fault indicator | |
| Variant | |
| Alarm value | 10 - 250 kOhm |
| Auxiliary voltage | AC/DC 85 - 230 V |
| Contact equipping | 2 x 1 changeover contact |
| Prewarning value | 20 kOhm - 1 MOhm |
| Approvals and Markings | UL-listed C/US, CCC |
Questions & answers
What is the delivery time of Dold 0070149 RN5897.12/300/61 AC/DC85-230V insulation monitor 10k-250k 20k-1M?
The article Dold 0070149 RN5897.12/300/61 AC/DC85-230V insulation monitor 10k-250k 20k-1M is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0070149 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0070149 RN5897.12/300/61 AC/DC85-230V insulation monitor 10k-250k 20k-1M always at the best possible price. We can give you a discount of 2% on Dold 0070149 RN5897.12/300/61 AC/DC85-230V insulation monitor 10k-250k 20k-1M if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0070149 RN5897.12/300/61 AC/DC85-230V insulation monitor 10k-250k 20k-1M we can offer you a price of 438,47 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.