Dold 0070148 RN5897.12/300/61 AC/DC24-60V insulation monitor 10k-250k 20k-1M
|
459,13 EUR |
|||||||||||
|
( 546,36 EUR incl. VAT ) ≈ £384.75 | ≈ $504.12 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001680 | ||||||||||
| Mfg Part No: | 0070148 | ||||||||||
| UPC/EAN: | 4030641701482 | ||||||||||
| Weight: | 0.335 kg | ||||||||||
| Type: | RN5897.12/300/61 AC/DC24-60V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0070148:
Applications
The insulation monitor is suitable for monitoring networks in various application areas, including UPS systems, networks with frequency converters, battery networks, DC drives, hybrid and battery-powered vehicles, as well as mobile power generators. It is universally applicable in systems that do not have direct earthing and enables continuous monitoring of insulation resistances, even when the network is de-energized.
Functions and equipment in detail
The device features two independently adjustable trip thresholds, which can be used for pre-alarm and alarm functions. The adjustment range for the pre-alarm value is between 20 kΩ and 1 MΩ, and for the alarm value between 10 kΩ and 250 kΩ. Adjustment is performed via three rotary switches on the front of the device, enabling user-friendly parameterization. The operating states are visualized via a multicolored device status LED, which indicates the current state of the device.
Technology explained simply
The insulation monitor measures the insulation resistance between the test terminals L(+) and L(-) as well as the protective earth terminals PE1 and PE2. An active measurement process with alternating polarity is carried out to detect symmetrical and asymmetrical insulation faults. The measurement is also performed when the network is de-energized, enabling continuous monitoring. The auxiliary voltage is supplied via terminals A1(+) and A2 and can be in the range AC/DC 24–60 V. The device features an automatic and manual self-test, which takes approximately 12 seconds after switching on the auxiliary voltage.
Compatibility and accessories
The device is designed for network leakage capacitances up to 30 μF and does not require an additional pre-stage device. The connection monitoring for the test circuit L(+) / L(-) is switchable off, while monitoring of the protective earth terminals PE1 / PE2 cannot be deactivated. An external control input (X1, X2) allows connection of a combined test/reset button. The contact configuration includes two 1-changeover contacts, used for the pre-alarm and alarm signals.
Mounting and installation
The insulation monitor is designed as an installation distributor and has a width of 52.5 mm, making it suitable for standard control panels. The terminals L(+) and L(-) are connected directly to the network to be monitored, while PE1 and PE2 must be connected to the protective earth system via separate conductors. The network type (AC, DC, 3NAC) is set via a rotary switch. The tamper-proof transparent cover protects the device against unauthorized manipulation.
Advantages in operation
With separate trip thresholds for pre-alarm and alarm, the operator can respond early to developing insulation degradation before a critical condition is reached. Alarm memory is selectable, so that an alarm remains stored even after the fault has cleared. Simple operation via rotary switches and visual indication via the LED facilitate maintenance and diagnosis. The device is designed for mobile applications and meets the requirements for use in mobile power generators.
Approvals and markings
The device is UL-listed C/US and carries the CCC mark. It complies with the requirements of standard IEC/EN 61557-8 and is suitable for use in IT systems with nominal voltages up to AC 230 V and DC 230 V. The auxiliary voltage can be in the range AC/DC 24–60 V, enabling flexible integration into various power supply systems. The device class is defined for mobile power generators, ensuring specific application safety.
| Technical data | |
| Approvals | UL |
| Classification | For mobile power generators |
| Enclosure design | Distribution board |
| IMD type | AC, AC/DC, DC |
| Nominal voltage IT system | AC 0 - 230 V, DC 0 - 230 V |
| Response value | 10 - 250 kΩ |
| Response value type | Adjustable |
| Width | 52,5 mm |
| Type | RN 5897/300 |
| Earth fault indicator | |
| Variant | |
| Alarm value | 10 - 250 kOhm |
| Auxiliary voltage | AC/DC 24 - 60 V |
| Contact equipping | 2 x 1 changeover contact |
| Prewarning value | 20 kOhm - 1 MOhm |
| Approvals and Markings | UL-listed C/US, CCC |
Questions & answers
What is the delivery time of Dold 0070148 RN5897.12/300/61 AC/DC24-60V insulation monitor 10k-250k 20k-1M?
The article Dold 0070148 RN5897.12/300/61 AC/DC24-60V insulation monitor 10k-250k 20k-1M is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0070148 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0070148 RN5897.12/300/61 AC/DC24-60V insulation monitor 10k-250k 20k-1M always at the best possible price. We can give you a discount of 2% on Dold 0070148 RN5897.12/300/61 AC/DC24-60V insulation monitor 10k-250k 20k-1M if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0070148 RN5897.12/300/61 AC/DC24-60V insulation monitor 10k-250k 20k-1M we can offer you a price of 438,47 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.