Dold 0070016 RN5897.12/060/61 AC/DC24-60V insulation monitor 1k-250k 20k-2M
|
632,67 EUR |
|||||||||||
|
( 752,88 EUR incl. VAT ) ≈ £530.18 | ≈ $694.67 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001695 | ||||||||||
| Mfg Part No: | 0070016 | ||||||||||
| UPC/EAN: | 4030641700164 | ||||||||||
| Weight: | 0.335 kg | ||||||||||
| Type: | RN5897.12/060/61 AC/DC24-60V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0070016:
Applications
The insulation monitor is universally applicable in various application areas, including UPS systems, networks with frequency converters, battery networks, DC drives, hybrid and battery-powered vehicles, as well as mobile power generators. It is designed for network capacitances up to 1000 μF and offers an optimized response time at high capacitances. Monitoring is carried out in accordance with IEC/EN 61557-8, ensuring a standardized and reliable measurement method.
Functions and Equipment in Detail
The device features two independently adjustable threshold settings: a warning threshold in the range of 20 kΩ to 2 MΩ and an alarm threshold from 1 kΩ to 250 kΩ. These settings are adjusted via two rotary switches on the front of the device. The display is a multi-colored illuminated screen showing the current insulation resistance, device status, and parameterization options. Monitoring of the measurement circuit L(+)/L(-) for wire break is switchable off, while monitoring of the protective conductor connection PE1/PE2 for wire break is not switchable off. A trigger output enables connection to an insulation fault detection system.
Technology Explained Simply
Insulation monitoring is performed by continuously measuring the resistance between the network conductors and the protective conductor. When the set thresholds are undershot, an alarm is triggered. Measurement can also be performed when the network is de-energized, enabling continuous monitoring even when idle. Monitoring of the measurement circuit for wire break ensures that a broken measurement circuit is detected to avoid false alarms. The tamper-proof transparent cover protects the device against unauthorized manipulation.
Compatibility and Accessories
The device can be combined with external pre-stage devices RL 5898, RP 5898, and RR 5898 to monitor higher rated voltages. RL 5898 is suitable for voltages up to AC 400 V / DC 500 V, RP 5898 for AC 690 V / DC 1000 V, and RR 5898 for AC 1000 V / DC 1500 V. Combining with these pre-stage devices extends the application range of the insulation monitor.
Mounting and Installation
The insulation monitor is designed as an installation distributor with a width of 52.5 mm. Power supply is via terminals A1(+) / A2 with auxiliary voltage AC/DC 24 to 60 V. After switching on the auxiliary voltage, an internal self-test runs, lasting approximately 12 seconds. Afterward, insulation resistance measurement begins. Connection examples and maximum voltages are described in the data sheet.
Operational Advantages
The insulation monitor provides preventive fire and system protection through early detection of insulation faults. Selective earth fault detection according to L+ and L- enables quick fault localization. Simple adjustment of thresholds and parameters via rotary switches and menu navigation facilitates commissioning. Alarm storage is selectable, and an external control input allows connection of a combined test/reset button. The measurement stop function is integrated to interrupt the measurement selectively.
Approvals and Markings
The device is UL-listed C/US and CCC-certified. Additionally, it has approvals according to DNV and UL, confirming its suitability for use in various industries and regions. Compliance with standards IEC/EN 61557-8 and the approvals ensure safe and reliable operation.
Enclosure Design and Mounting
The device is designed as an installation distributor with a width of 52.5 mm. The tamper-proof transparent cover protects the device against manipulation. Mounting is in standard distributor boxes, with connection terminals for auxiliary voltage and measurement circuits clearly labeled.
Functions for Safety and Reliability
The insulation monitor features an automatic and manual device self-test to check functionality. Monitoring of the measurement circuit for wire break ensures detection of a broken measurement circuit. Monitoring of the protective conductor connection PE1/PE2 for wire break is not switchable off to ensure continuous monitoring of the protective conductor. Alarm storage is selectable to document alarm history.
Application-Specific Features
The device is suitable for use in IT systems with high network capacitances. Setting the maximum network capacitance allows for shortening the response time. The operating or standby current principle for alarm relays is adjustable to adapt the alarm function to requirements. The multi-colored display facilitates interpretation of the device status.
| Technical data | |
| Approvals | DNV, UL |
| Enclosure design | Distribution board |
| IMD type | AC, AC/DC, DC |
| Nominal voltage IT system | AC 0 - 230 V, AC 0 - 1000 (Coupling device) V, DC 0 - 230 V, DC 0 - 1500 (Coupling device) V |
| Response value | 1 - 250 kΩ |
| Response value type | Adjustable |
| Width | 52,5 mm |
| Type | RN 5897/010 |
| Earth fault indicator | |
| Variant | |
| Alarm value | 1 - 250 kOhm |
| Auxiliary voltage | AC/DC 24 - 60 V |
| Contact equipping | 2 x 1 changeover contact |
| Prewarning value | 20 kOhm - 2 MOhm |
| Approvals and Markings | UL-listed C/US, CCC |
| Variant | With measuring stop function |
Questions & answers
What is the delivery time of Dold 0070016 RN5897.12/060/61 AC/DC24-60V insulation monitor 1k-250k 20k-2M?
The article Dold 0070016 RN5897.12/060/61 AC/DC24-60V insulation monitor 1k-250k 20k-2M is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0070016 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0070016 RN5897.12/060/61 AC/DC24-60V insulation monitor 1k-250k 20k-2M always at the best possible price. We can give you a discount of 2% on Dold 0070016 RN5897.12/060/61 AC/DC24-60V insulation monitor 1k-250k 20k-2M if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0070016 RN5897.12/060/61 AC/DC24-60V insulation monitor 1k-250k 20k-2M we can offer you a price of 604,20 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.