Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

Dold 0070015 RN5897.12/011/61 AC/DC100-230V insulation monitor 1K-2M 1K-2M

Your rating:
Average rating
product review for Dold 0070015 RN5897.12/011/61 AC/DC100-230V insulation monitor 1K-2M 1K-2M
( 4.3 / 5 ) 3 ratings
Dold 0070015
This image may differ from the desired article.
709,24 EUR
( 844,00 EUR incl. VAT )
≈ £594.34  |  ≈ $778.75
plus delivery charges: 55,00 €
On order · Delivery time approx. 20 workdaysinfo_outline
1x Dold 0070015 RN5897.12/011/61 AC/DC100-230V insulation monitor 1K-2M 1K-2M
Datasheet:file_download Download
Lieske Part No.:1001696
Mfg Part No: 0070015
UPC/EAN: 4030641700157
Weight:0.335 kg
Type:RN5897.12/011/61 AC/DC100-230V
Graduated prices net
From piecesPrice per pieces
3677,32 EUR
6645,41 EUR
9613,49 EUR
12581,58 EUR

Product information for Dold 0070015:

The insulation monitor RN5897.12/011/61 AC/DC100-230V from Dold is a device for monitoring insulation in IT systems, particularly in ungrounded AC, DC, and mixed AC/DC networks. The device belongs to the VARIMETER IMD family and is used for continuous monitoring of the insulation resistance between the line conductors L(+) and L(-) as well as the protective conductor PE1/PE2. It is suitable for use in industrial plants, UPS systems, networks with frequency converters, battery networks, DC drives, hybrid and battery-powered vehicles, as well as mobile power generators. The function is based on insulation monitoring according to IEC/EN 61557-8, with the trip threshold adjustable in the range of 1 to 2000 kΩ. Adjustment is performed via two rotary switches on the device front, allowing two independent trip thresholds for pre-alarm and alarm to be defined. The adjustment range for both values is between 1 kΩ and 2 MΩ.

Applications

The device is universally applicable in IT systems with nominal voltages up to AC 250 V or DC 300 V. When used with an external pre-stage device (e.g. RL 5898, RP 5898 or RR 5898), the nominal voltage can be extended to AC 1000 V or DC 1500 V. Monitoring also occurs when the network is de-energized, ensuring continuous safety function. The maximum network capacitance is 1000 μF, with optimized response time at high capacitances. Measurement takes place in the measuring circuit between L(+) / L(-) and PE1/PE2, with integrated wire break monitoring for the measuring circuit (switchable) and for the protective conductor PE1/PE2 (non-switchable).

Functions and Equipment in Detail

The insulation monitor features two galvanically isolated 1-changeover contacts, each used for pre-alarm and alarm. Indication is provided via a multi-coloured illuminated display, showing the current insulation resistance, device status and parameter settings. Operation is performed via the rotary switches and menu navigation on the display. Additionally, an external control input is available for a combined test/reset button. Alarm memory is selectable, and an automatic and manual device self-test is integrated. The tamper-proof transparent cover protects the device against unauthorized manipulation.

Technology Explained Simply

Monitoring is performed via a measuring circuit that measures the insulation resistance between the network conductors and the protective conductor. The trip thresholds are adjustable, enabling early warning (pre-alarm) when insulation resistance decreases and an alarm at critical values. Galvanic isolation of the contacts ensures safe signal transmission. The Modbus RTU interface enables remote reading and parameterization of all measured values, device states and parameters. The auxiliary voltage is supplied via terminals A1(+) / A2 with AC/DC 100–230 V. The width is 52.5 mm, allowing installation in standard installation distributors.

Compatibility and Accessories

The device is compatible with external pre-stage devices of types RL 5898, RP 5898 and RR 5898, which extend the system’s nominal voltage. The Modbus RTU interface enables integration into higher-level control and monitoring systems. A trigger output for insulation fault detection systems is also available to support fault localization.

Mounting and Installation

Mounting is performed in an installation distributor. The width of 52.5 mm corresponds to the standard for DIN rail mounting. The auxiliary voltage is connected via terminals A1(+) / A2. Network connections are made via terminals L(+) / L(-) and PE1/PE2. The device front is equipped with rotary switches and a display for parameterization and indication. The tamper-proof cover is sealed after commissioning to prevent manipulation.

Operational Advantages

The insulation monitor provides preventive fire and plant protection through early detection of insulation faults. Selective earth fault detection according to L+ and L- enables quick fault localization. Galvanically isolated contacts and the Modbus interface increase reliability and integration into existing systems. Adjustable trip thresholds and monitoring even when the network is de-energized ensure flexible and safe use in various application scenarios. The certifications UL-listed C/US and DNV confirm suitability for use in respective markets.

Approvals and Markings

The device is certified with UL-listed C/US and DNV, confirming compliance with respective safety and quality requirements. Monitoring is performed according to IEC/EN 61557-8, ensuring application in industrial and technical installations.

Technical data
ApprovalsDNV, UL
Bus interfaceModbus RTU
Enclosure designDistribution board
IMD typeAC, AC/DC, DC
Nominal voltage IT systemAC 0 - 230 V, AC 0 - 1000 (Coupling device) V, DC 0 - 230 V, DC 0 - 1500 (Coupling device) V
Response value1 - 2000 kΩ
Response value typeAdjustable
Width52,5 mm
TypeRN 5897/011
Earth fault indicatorYes
Variant
Alarm value1 kOhm - 2 MOhm
Auxiliary voltageAC/DC 100 - 230 V
Contact equipping2 x 1 changeover contact
Prewarning value1 kOhm - 2 MOhm
Approvals and MarkingsUL-listed C/US, DNV


Product data sheet
Datasheet for Dold 0070015, EAN: 4030641700157

Questions & answers

What is the delivery time of Dold 0070015 RN5897.12/011/61 AC/DC100-230V insulation monitor 1K-2M 1K-2M?

The article Dold 0070015 RN5897.12/011/61 AC/DC100-230V insulation monitor 1K-2M 1K-2M is currently not in stock but has been backordered.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0070015 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0070015 RN5897.12/011/61 AC/DC100-230V insulation monitor 1K-2M 1K-2M always at the best possible price. We can give you a discount of 2% on Dold 0070015 RN5897.12/011/61 AC/DC100-230V insulation monitor 1K-2M 1K-2M if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0070015 RN5897.12/011/61 AC/DC100-230V insulation monitor 1K-2M 1K-2M we can offer you a price of 677,32 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0070015 RN5897.12/011/61 AC/DC100-230V insulation monitor 1K-2M
Dold 0070015 RN5897.12/011/61 AC/DC100-230V insulation monitor 1K-2M 1K-2M
709,24 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0070015 RN5897.12/011/61 AC/DC100-230V insulation monitor 1K-2M
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
8 + 9 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.