Dold 0070014 RN5897.12/011/61 AC/DC24-60V insulation monitor 1K-2M 1K-2M
|
709,24 EUR |
|||||||||||
|
( 844,00 EUR incl. VAT ) ≈ £594.34 | ≈ $778.75 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001697 | ||||||||||
| Mfg Part No: | 0070014 | ||||||||||
| UPC/EAN: | 4030641700140 | ||||||||||
| Weight: | 0.335 kg | ||||||||||
| Type: | RN5897.12/011/61 AC/DC24-60V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0070014:
Applications
The RN5897/011 is universally applicable in IT systems with rated voltages up to AC 250 V or DC 300 V. When used with an external pre-stage device (e.g. RL 5898, RP 5898 or RR 5898), the rated voltage can be extended up to AC 1000 V or DC 1500 V. The device is designed for network capacitances up to 1000 μF and offers an optimized response time at high capacitances. It also enables monitoring in de-energized networks, which is important for safety in stationary installations.
Functions and equipment in detail
The device features two independently adjustable threshold settings, which can be used for pre-alarm and alarm. The adjustment range for both values is between 1 kΩ and 2 MΩ. Adjustment is performed via two rotary switches on the front of the device, ensuring user-friendly parameterization. Additionally, parameterization can be done via a Modbus RTU interface, which is galvanically isolated. A multicolored display shows the current insulation resistance, device status, and other parameters. The earth fault indication is integrated.
Technology explained simply
The insulation monitor operates with a measurement circuit between L(+) / L(-) and PE1 / PE2. The measurement is performed using an auxiliary voltage in the range AC/DC 24–60 V, supplied via terminals A1(+) / A2. After switching on the auxiliary voltage, the device performs an internal self-test, which takes approximately 12 seconds. Afterward, continuous measurement of the insulation resistance begins. The response time is optimized based on the setting of the maximum network capacitance. Wire break monitoring in the measurement circuit (L(+)/L(-)) is switchable off, while protective conductor connection monitoring (PE1/PE2) is not switchable off. A trigger output allows connection to an insulation fault detection system.
Compatibility and accessories
The device is compatible with external pre-stage devices that extend the system's rated voltage. The pre-stage devices RL 5898, RP 5898, and RR 5898 enable operation at higher voltages. The Modbus RTU interface allows remote reading and parameterization of all measured values, statuses, and settings. Functions can also be operated via Modbus. An external control input allows connection of a combined test/reset button.
Mounting and installation
The insulation monitor is designed as an installation distributor with a width of 52.5 mm. Mounting is done in standard distributor boxes. The terminals are intended for connection cables, with the auxiliary voltage supplied via A1(+) / A2. The tamper-proof transparent cover protects the device against unauthorized manipulation.
Advantages in operation
The device provides preventive fire and plant protection through early detection of insulation faults. It detects both symmetrical and asymmetrical faults and enables fast fault localization through selective earth fault detection according to L+ and L-. The galvanically isolated contacts (2 x 1 changeover) ensure safe signal transmission. Alarm storage is selectable, and automatic and manual device self-tests ensure reliability. Adjustment of threshold values and parameters is simple via rotary switches or Modbus, simplifying maintenance and commissioning. The certifications UL-listed C/US and DNV confirm suitability for use in corresponding application areas.
| Technical data | |
| Approvals | DNV, UL |
| Bus interface | Modbus RTU |
| Enclosure design | Distribution board |
| IMD type | AC, AC/DC, DC |
| Nominal voltage IT system | AC 0 - 230 V, AC 0 - 1000 (Coupling device) V, DC 0 - 230 V, DC 0 - 1500 (Coupling device) V |
| Response value | 1 - 2000 kΩ |
| Response value type | Adjustable |
| Width | 52,5 mm |
| Type | RN 5897/011 |
| Earth fault indicator | |
| Variant | |
| Alarm value | 1 kOhm - 2 MOhm |
| Auxiliary voltage | AC/DC 24 - 60 V |
| Contact equipping | 2 x 1 changeover contact |
| Prewarning value | 1 kOhm - 2 MOhm |
| Approvals and Markings | UL-listed C/US, DNV |
Questions & answers
What is the delivery time of Dold 0070014 RN5897.12/011/61 AC/DC24-60V insulation monitor 1K-2M 1K-2M?
The article Dold 0070014 RN5897.12/011/61 AC/DC24-60V insulation monitor 1K-2M 1K-2M is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0070014 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0070014 RN5897.12/011/61 AC/DC24-60V insulation monitor 1K-2M 1K-2M always at the best possible price. We can give you a discount of 2% on Dold 0070014 RN5897.12/011/61 AC/DC24-60V insulation monitor 1K-2M 1K-2M if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0070014 RN5897.12/011/61 AC/DC24-60V insulation monitor 1K-2M 1K-2M we can offer you a price of 677,32 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.