Dold 0070013 RN5897.12/010/61 DC12-24V insulation monitor 1k-250k 20k-2M
|
632,67 EUR |
|||||||||||
|
( 752,88 EUR incl. VAT ) ≈ £530.18 | ≈ $694.67 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001693 | ||||||||||
| Mfg Part No: | 0070013 | ||||||||||
| UPC/EAN: | 4030641700133 | ||||||||||
| Weight: | 0.335 kg | ||||||||||
| Type: | RN5897.12/010/61 DC12-24V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0070013:
Applications
The insulation monitor is universally applicable in various systems, including UPS systems, networks with frequency converters, battery networks, DC drives, hybrid and battery-powered vehicles, as well as mobile power generators. It monitors both AC and DC networks up to a maximum of 250 V AC or 300 V DC. The use of an external pre-stage device (e.g. RL 5898, RP 5898 or RR 5898) can extend the maximum rated voltages to AC 1000 V or DC 1500 V. Monitoring also occurs when the network is de-energized, increasing reliability in critical operating conditions.
Functions and Equipment in Detail
The device features two independently adjustable threshold settings: a pre-alarm level ranging from 20 kΩ to 2 MΩ and an alarm level from 1 kΩ to 250 kΩ. These values can be easily and user-friendly adjusted via two rotary switches on the front of the device. Display is provided by a multi-colored illuminated screen showing the current insulation resistance, device status, and parameterization options. Selective earth fault detection for L+ and L– enables quick fault localization. Additionally, an integrated trigger output is available for insulation fault detection systems.
Technology Explained Simply
Insulation monitoring is performed according to the standard IEC/EN 61557-8. The device detects both symmetrical and asymmetrical insulation faults. Measurement takes place in the measuring circuit between terminals L(+) / L(–) and PE1 / PE2. The response time is optimized by setting the maximum network capacitance (up to 1000 μF), which is particularly important for systems with high capacitance. Wire break monitoring in the measuring circuit is switchable off, while monitoring of the protective conductor connections PE1/PE2 is not switchable off. The operating mode of the alarm relay (active or rest current principle) is adjustable.
Compatibility and Accessories
The insulation monitor can be operated both with and without an external pre-stage device. Combining it with pre-stage devices RL 5898, RP 5898 or RR 5898 extends the maximum rated voltages. The auxiliary voltage is supplied via terminals A1(+) / A2. An external control input allows the use of a combined test/reset button. The tamper-proof transparent cover protects the device against unauthorized manipulation.
Mounting and Installation
The device is mounted in installation distributors and requires a module width of 52.5 mm. The connection terminals are clearly labeled, with terminals L(+) and L(–) connected directly to the network to be monitored. When using a pre-stage device, the connection is made via the corresponding terminals. After switching on the auxiliary voltage, the device performs an internal self-test lasting approximately 12 seconds, which is displayed on the screen.
Advantages in Operation
The insulation monitor provides preventive fire and system protection through early detection of insulation faults. The two-stage alarm function (pre-alarm and alarm) allows for differentiated response to decreasing insulation values. Alarm memory is selectable, and automatic and manual device self-tests ensure operational reliability. The clear display and simple parameterization reduce maintenance time and increase operational safety. Certifications UL-listed C/US, CCC, DNV, and UL confirm suitability for use in various markets.
| Technical data | |
| Approvals | DNV, UL |
| Enclosure design | Distribution board |
| IMD type | AC, AC/DC, DC |
| Nominal voltage IT system | AC 0 - 230 V, AC 0 - 1000 (Coupling device) V, DC 0 - 230 V, DC 0 - 1500 (Coupling device) V |
| Response value | 1 - 250 kΩ |
| Response value type | Adjustable |
| Width | 52,5 mm |
| Type | RN 5897/010 |
| Earth fault indicator | |
| Variant | |
| Alarm value | 1 - 250 kOhm |
| Auxiliary voltage | DC 12 - 24 V |
| Contact equipping | 2 x 1 changeover contact |
| Prewarning value | 20 kOhm - 2 MOhm |
| Approvals and Markings | UL-listed C/US, CCC |
Questions & answers
What is the delivery time of Dold 0070013 RN5897.12/010/61 DC12-24V insulation monitor 1k-250k 20k-2M?
The article Dold 0070013 RN5897.12/010/61 DC12-24V insulation monitor 1k-250k 20k-2M is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0070013 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0070013 RN5897.12/010/61 DC12-24V insulation monitor 1k-250k 20k-2M always at the best possible price. We can give you a discount of 2% on Dold 0070013 RN5897.12/010/61 DC12-24V insulation monitor 1k-250k 20k-2M if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0070013 RN5897.12/010/61 DC12-24V insulation monitor 1k-250k 20k-2M we can offer you a price of 604,20 EUR per piece. The more you buy, the cheaper the article will be.