Dold 0069881 RN5893.12/100/61 AC/DC100-240V 5µF insulation monitor 1k-500k 1k-500k
|
684,28 EUR |
|||||||||||
|
( 814,29 EUR incl. VAT ) ≈ £573.43 | ≈ $751.34 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001699 | ||||||||||
| Mfg Part No: | 0069881 | ||||||||||
| UPC/EAN: | 4030641698812 | ||||||||||
| Weight: | 0.205 kg | ||||||||||
| Type: | RN5893.12/100/61 AC/DC100-240V 5µF | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0069881:
Applications
The insulation monitor is primarily intended for DC charging stations with voltages up to DC 1000 V. The use of an external pre-stage device RP 5898 enables monitoring of nominal voltages up to AC 690 V or DC 1000 V. It is also suitable for UPS systems, networks with frequency converters, battery networks, DC drives, hybrid and battery-powered vehicles, as well as mobile power generators. The application is in ungrounded systems, with a maximum operating voltage of AC 250 V or DC 300 V if no pre-stage device is used.
Functions and Equipment in Detail
The device features two independently adjustable trip thresholds, which can be used as a pre-alarm value and an alarm value. The adjustment range for both values is between 1 kΩ and 500 kΩ. Monitoring is performed via two configurable changeover contacts, each electrically isolated. These can be configured for various functions such as insulation fault alarm, pre-alarm, fault on DC+/DC−, or device fault. The operating mode of the alarm relays (active or passive current principle) is also adjustable.
Technology Explained Simply
Insulation monitoring is performed by an optimized measurement of insulation resistance, which functions reliably even with voltage fluctuations in the network. The measurement is based on evaluation of the network voltage. The response time of the device is a maximum of 1 second. A multicolored device status LED provides user-friendly visualization of the operating state. A manual self-test is available, and an automatic self-test can also be activated. Alarm storage is selectable, and the measurement circuits L(+) and L(−) as well as the protective earth connections PE1/PE2 are monitored for wire breakage (PE monitoring cannot be disabled). Monitoring also occurs when the network is de-energized.
Compatibility and Accessories
The device is equipped with a galvanically isolated Modbus RTU interface, via which all measured values, device states, and parameters can be read and configured. Configuration via Modbus enables remote control and monitoring. The connection option for an external pre-stage device RP 5898 extends the application range to higher voltages. The width is 52.5 mm, allowing installation in standard installation distributors.
Mounting and Installation
Power supply is via terminals A1(+) and A2 with auxiliary voltage AC/DC 100–240 V. After switching on the auxiliary voltage, the device performs an internal self-test. Mounting is in an installation distributor, where the tamper-proof transparent cover protects against unauthorized manipulation. An external control input allows connection of a combined test/reset button, with the additional option to pause the measurement function.
Advantages in Operation
The insulation monitor provides preventive fire and system protection through early detection of symmetrical and asymmetrical insulation faults. The adjustment of trip thresholds is simple via Modbus, facilitating integration into higher-level control systems. The extended operating temperature range of −40 °C to +70 °C makes the device suitable for demanding environments. The UL-Recognized (C/US) certification ensures use in corresponding markets.
| Technical data | |
| Approvals | UL-Recognized |
| Bus interface | Modbus RTU |
| Classification | For DC charging stations |
| Enclosure design | Distribution board |
| IMD type | AC, AC/DC, DC |
| Nominal voltage IT system | AC 0 - 230 V, AC 0 - 690 (Coupling device) V, DC 0 - 230 V, DC 0 - 1000 (Coupling device) V |
| Response value | 1 - 500 kΩ |
| Response value type | Adjustable |
| Width | 52,5 mm |
| Type | RN 5893/100 |
| Earth fault indicator | |
| Variant | |
| Alarm value | 1 - 500 kOhm |
| Auxiliary voltage | AC/DC 100 - 240 V |
| Contact equipping | 2 x 1 changeover contact |
| Prewarning value | 1 - 500 kOhm |
| Approvals and Markings | UL-rec. C/US |
| Variant | Für Netzableitkapazitäten bis 5 µF |
Questions & answers
What is the delivery time of Dold 0069881 RN5893.12/100/61 AC/DC100-240V 5µF insulation monitor 1k-500k 1k-500k?
The article Dold 0069881 RN5893.12/100/61 AC/DC100-240V 5µF insulation monitor 1k-500k 1k-500k is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0069881 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0069881 RN5893.12/100/61 AC/DC100-240V 5µF insulation monitor 1k-500k 1k-500k always at the best possible price. We can give you a discount of 2% on Dold 0069881 RN5893.12/100/61 AC/DC100-240V 5µF insulation monitor 1k-500k 1k-500k if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0069881 RN5893.12/100/61 AC/DC100-240V 5µF insulation monitor 1k-500k 1k-500k we can offer you a price of 653,49 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.