Dold 0069632
This image may differ from the desired article.
2.034,88 EUR
( 2.421,51 EUR incl. VAT )
≈ £1,705.23  |  ≈ $2,234.30
plus delivery charges: 55,00 €
On order · Delivery time approx. 20 workdaysinfo_outline
1x Dold 0069632 LK5895.12/800/61 DC24V 1k-250k insulation monitor 1k-250k
Datasheet:file_download Download
Lieske Part No.:100167
Mfg Part No: 0069632
UPC/EAN: 4030641696320
Weight:0.5 kg
Type:LK5895.12/800/61 DC24V 1k-250k
Graduated prices net
From piecesPrice per pieces
21.943,31 EUR
41.851,74 EUR
61.760,17 EUR
81.668,60 EUR

Product information for Dold 0069632:

The insulation monitor LK 5895 of the VARIMETER IMD family from Dold is a device for monitoring insulation quality in IT systems, particularly in ungrounded AC, DC, and mixed AC/DC networks with a nominal voltage up to 1000 V. It is designed for early detection of insulation faults to ensure preventive fire and system protection. The device is specifically designed for use in photovoltaic systems, including those with thin-film technology, as well as in battery networks, UPS systems, and networks with frequency converters. Insulation monitoring is performed in accordance with the standard IEC/EN 61557-8, ensuring the reliability and safety of the measurement.

Applications

The LK 5895 is universally applicable in various applications, including photovoltaic systems, hybrid and battery vehicles, networks with DC drives, and systems with high network capacitance up to 3000 μF. Monitoring is also possible in de-energized networks, making it particularly suitable for installations with intermittent power supply. Selective earth fault detection on L+ and L– enables rapid fault localization, reducing maintenance and downtime.

Functions and Equipment in Detail

The device features two adjustable threshold values: the alarm threshold in the range of 1 kΩ to 250 kΩ and the pre-alarm threshold, which can also be set in the range of 1 kΩ to 250 kΩ. Adjustment is performed via two ratchet rotary switches on the front of the device, which can be operated with a screwdriver. This ensures simple and clear operation. Measured values and device status are displayed via an LED bar, visually indicating the current insulation resistance. Additionally, a green LED labeled PWR lights up when supplied with DC auxiliary voltage.

Technology Explained Simply

The monitoring technology is based on an adapted measurement algorithm that reduces response time in networks with high capacitance. The measurement circuits can be deactivated via control terminals, for example, during network coupling. Measurement circuit monitoring includes wire break detection on L(+) and L(–), enabling detection of interruptions in the measurement circuit. The output relays operate on either the energized or de-energized principle, with selection possible depending on the application. An automatic and manual device self-test ensures functional verification of the device.

Compatibility and Accessories

The device is designed for IT systems with AC and DC voltages up to 1000 V. It detects both symmetrical and asymmetrical insulation faults. The contact configuration includes one changeover contact each for pre-alarm and alarm. External test and reset buttons can be connected to allow external verification of functionality or to reset the alarm state. Alarm memory is selectable, so an alarm can be retained even after the fault has disappeared.

Mounting and Installation

The device is designed for installation in enclosures and has a width of 90 mm. Connections are clearly labeled: A1+ and A2 for DC auxiliary voltage (24 V), L(+) and L(–) for the measurement circuit, KE and PE for the protective conductor, and control terminals G, R, T, and HM for configuring the operating behavior. Installation is done via screw terminals, ensuring a secure connection.

Operational Advantages

The LK 5895 offers an optimized measurement time, typically shorter than with conventional methods. Measurement is performed without an additional pre-stage device, simplifying installation. The visual display of insulation resistance via the LED bar enables quick visual inspection of the system status. The combination of simple operation, high reliability, and universal applicability makes the device a robust solution for insulation monitoring in modern electrical systems.

Approvals and Markings

The device is UL-listed C/US and UKCA-certified, confirming compliance with relevant safety and quality standards in the USA and the United Kingdom. These approvals ensure suitability for use in corresponding markets and applications.

Core Functions at a Glance

  • Insulation monitoring according to IEC/EN 61557-8
  • Adjustable thresholds for alarm and pre-alarm
  • LED display for insulation resistance and device status
  • Wire break detection on L(+) and L(–)
  • Universal applicability in AC, DC, and AC/DC networks up to 1000 V
  • Approvals UL-listed C/US, UKCA

The technical features such as auxiliary voltage (DC 24 V), contact configuration (2 x 1 changeover contact), and adjustment ranges for pre-alarm and alarm thresholds (20 kΩ to 2 MΩ and 1 kΩ to 250 kΩ respectively) are integrated into the device and correspond to the manufacturer’s specifications. The device class is specified for photovoltaic systems, although use in other IT systems is also possible.

Technical data
ApprovalsUL
ClassificationFor photovoltaic systems
Enclosure designSwitch cabinet
IMD typeAC, AC/DC, DC
Nominal voltage IT systemAC 0 - 1000 V, DC 0 - 1000 V
Response value1 - 250 kΩ
Response value typeAdjustable
Width90 mm
TypeLK 5895
Earth fault indicatorYes
Variant
Alarm value1 - 250 kOhm
Auxiliary voltageDC 24 V
Contact equipping2 x 1 changeover contact
Prewarning value1 - 250 kOhm
Approvals and MarkingsUL-listed C/US, UKCA
VariantWith wire-break detection at L(+)/L(-). Without analog output. With adapted measurement algorithm


Product data sheet
Datasheet for Dold 0069632, EAN: 4030641696320

Questions & answers

What is the delivery time of Dold 0069632 LK5895.12/800/61 DC24V 1k-250k insulation monitor 1k-250k?

The article Dold 0069632 LK5895.12/800/61 DC24V 1k-250k insulation monitor 1k-250k is currently not in stock but has been backordered.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0069632 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0069632 LK5895.12/800/61 DC24V 1k-250k insulation monitor 1k-250k always at the best possible price. We can give you a discount of 2% on Dold 0069632 LK5895.12/800/61 DC24V 1k-250k insulation monitor 1k-250k if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 2 pieces of Dold 0069632 LK5895.12/800/61 DC24V 1k-250k insulation monitor 1k-250k we can offer you a price of 1.943,31 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0069632 insulation monitor 1k-250k DC24V
Dold 0069632 LK5895.12/800/61 DC24V 1k-250k insulation monitor 1k-250k
2.034,88 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0069632 insulation monitor 1k-250k DC24V
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
2 + 5 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.