Dold 0069519 RL9405/100 3/N AC80-230V 50Hz energy meter
|
360,52 EUR |
|||||||||||
|
( 429,02 EUR incl. VAT ) ≈ £302.12 | ≈ $395.85 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1000977 | ||||||||||
| Mfg Part No: | 0069519 | ||||||||||
| UPC/EAN: | 4030641695194 | ||||||||||
| Weight: | 0.105 kg | ||||||||||
| Type: | RL9405/100 3/N AC80-230V 50Hz | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0069519:
Applications
The energy meter RL9405/100 is intended for measurement in 3-phase networks with neutral conductor, regardless of whether it is an IT-, TN- or TT-system. It is used in industrial and commercial facilities where accurate measurement of voltage, current, power, and energy consumption is required. Measurement is continuous, capturing effective and peak values of phase voltage and phase current, network frequency, power factor, active power, reactive power, apparent power, active energy, reactive energy, and apparent energy. Measurement accuracy is ±0.5 %, sufficient for reliable data acquisition in monitoring and control systems.
Functions and equipment in detail
The device features an integrated memory that stores energy consumption even after power supply is switched off. Current transformer ratios can be set via Modbus, allowing adaptation to market-standard current transformers with secondary rated currents of 100 mA, 1 A, or 5 A, and a secondary rated voltage of 333 mV. Measurement ranges extend up to 1000 A when using external current transformers. The Modbus RTU interface supports baud rates of 9600, 19200, and 38400 bit/s and allows setting the slave address from 1 to 99 directly on the device.
Technology explained simply
The voltage inputs (L1, L2, L3, N) serve both as power supply source and as measurement channels. Current measurement is performed via external current transformers connected to terminals i1, k1, i2, k2, i3, k3. The RS485 interface (terminals GND, A, B) enables communication via Modbus RTU. Galvanic isolation of the interface protects the device and connected equipment from voltage surges. The operating voltage is generated from the measurement voltage of all three phases, allowing the device to operate independently of a separate power supply. The minimum current is 0.05 % of the rated output current multiplied by the current transformer ratio.
Compatibility and accessories
The energy meter RL9405/100 is designed for use with current transformers having a secondary rated current of 1 A. It can be connected to market-standard current transformers, whose winding ratio can be set via Modbus. The Modbus RTU interface enables connection to systems supporting the Modbus protocol. Device indicators consist of a green LED (ON, indicating applied operating voltage) and a yellow LED (BUS, indicating RS485 bus activity).
Mounting and installation
The device is installed in enclosures or installation small distributors. Mounting is done in standard 35 mm width, fitting into typical enclosure modules. Connection terminals are clearly labeled (L1, L2, L3, N for voltage, i1–i3, k1–k3 for current, GND, A, B for RS485). Current transformers must be connected externally, with terminals i1–i3 and k1–k3 assigned to respective phases. The Modbus address and baud rate can be set directly on the device.
Advantages in operation
The compact design with 35 mm width frees up more space in the enclosure. Permanent storage of energy measurement values enables continuous documentation even during power failure. Power supply from the measurement voltage reduces the number of required supply lines. The Modbus RTU interface provides a standardized interface for integration into existing monitoring and control systems. Measurement accuracy of ±0.5 % ensures reliable data for operational monitoring. The device is not intended for billing purposes according to EU Directive 2004/22/EC (MID) and therefore must not be used as an electricity meter for active energy consumption.
| Technical data | |
| 1- / 3-phase | 3 |
| Auxiliary voltage | Without |
| Bus interface | Modbus RTU |
| Enclosure design | Distribution board |
| Measuring range max. | 230 V |
| Standard measuring range | 3/N AC 80 - 230 V |
| Width | 35 mm |
| Type | RL 9405 |
| Variant | |
| Nominal voltage | 3/N AC 80 - 230 V / 140 - 400 V 50 Hz |
| Variant | Secondary rated current of the current transformers 1 A |
Questions & answers
What is the delivery time of Dold 0069519 RL9405/100 3/N AC80-230V 50Hz energy meter?
The article Dold 0069519 RL9405/100 3/N AC80-230V 50Hz energy meter is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0069519 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0069519 RL9405/100 3/N AC80-230V 50Hz energy meter always at the best possible price. We can give you a discount of 2% on Dold 0069519 RL9405/100 3/N AC80-230V 50Hz energy meter if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0069519 RL9405/100 3/N AC80-230V 50Hz energy meter we can offer you a price of 344,30 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.