Mfg Part No: 0069400
UPC/EAN: 4030641694005
Weight:0.335 kg
Type:RN5897.12/321/61 AC/DC100-230V
Graduated prices net
From piecesPrice per pieces
3653,49 EUR
6622,69 EUR
9591,90 EUR
12561,11 EUR

Product information for Dold 0069400:

The insulation monitor RN5897/321 from Dold is a device of the VARIMETER IMD family for monitoring insulation quality in IT systems. It is designed for use in ungrounded AC, DC, and mixed AC/DC networks and is particularly suitable for DC charging stations for electric vehicles operated in accordance with IEC/EN 61851-23:2014/AC:2016-06. The device continuously monitors insulation and responds to earth faults or insulation degradation with defined trip thresholds. Parameterization is performed via a galvanically isolated Modbus RTU interface, enabling secure communication. Operating states are user-friendly visualized via a multicolored status LED.

Applications

The insulation monitor is intended for applications in modern IT systems, particularly in DC charging stations for electric vehicles with network voltages up to DC 1000 V. It is also suitable for UPS systems, networks with frequency converters, battery networks, DC drives, hybrid and battery-powered vehicles, as well as mobile power generators. The devices are designed for use in ungrounded networks, where the rated voltage of the IT system reaches up to AC 230 V or DC 230 V. When used with an external pre-stage device (RL 5898 or RP 5898), the rated voltage can be extended up to AC 690 V or DC 1000 V.

Functions and Equipment in Detail

The device features two independently adjustable trip thresholds, which can be used for pre-alarm and alarm functions. The adjustment range for both values is between 1 kΩ and 500 kΩ. Each trip threshold is signaled via a separate 1-changeover contact. The alarm relays can operate in either energized or de-energized mode, with the setting adjustable via Modbus. An automatic self-test is performed after each full hour of operation to ensure device functionality. Alarm memory is selectable, allowing alarm history to remain available even after a reset.

Technology Explained Simply

Insulation monitoring is performed in accordance with IEC/EN 61557-8. The device detects both symmetrical and asymmetrical insulation faults and can also monitor during de-energized network conditions. The measurement is optimized for network voltage fluctuations, utilizing network voltage for evaluation. The response time is maximum 1 second. Circuit monitoring for L(+) and L(-) detects wire breaks and is switchable off. Protective conductor connection monitoring for PE1 and PE2 is not switchable off. The auxiliary voltage can be operated in the range AC/DC 100–230 V. The width is 52.5 mm, enabling installation in standard installation distributors.

Compatibility and Accessories

The device can be combined with external pre-stage devices RL 5898 (for rated voltages up to AC 400 V / DC 500 V) or RP 5898 (for rated voltages up to AC 690 V / DC 1000 V) to monitor higher voltages. Communication is via Modbus RTU, allowing all measured values, device states, and parameters to be read and functions to be controlled. An external control input enables connection of a combined test/reset button, with additional capability to pause the measurement function.

Mounting and Installation

The insulation monitor is designed as an installation distributor and can be mounted in standard switchboards. Connections are clearly labeled: A1(+) and A2 for auxiliary voltage, L(+) and L(-) as well as VSG1 and VSG2 for the measurement circuit or pre-stage device, PE1 and PE2 for protective conductor, X1 and X2 for control input. The terminals are designed for secure connections. The tamper-proof transparent cover protects the device against unauthorized manipulation.

Advantages in Operation

The device provides preventive fire and system protection through early detection of insulation faults. Setting trip thresholds and parameters is simple via Modbus, enabling centralized control and monitoring. The operating temperature range extends from -40 °C to +70 °C, allowing use in demanding environments. The network capacitance can be up to 5 μF. The galvanic isolation of the Modbus interface increases safety and immunity to interference. The earth fault indication is integrated, enabling the operator to react directly to a fault.

Approvals

The device is UL-listed C/US and complies with the requirements of standard IEC/EN 61851-23:2014/AC:2016-06 for DC charging stations. Approvals and markings are documented in the datasheet and confirm suitability for use in corresponding installations.

Technical data
ApprovalsUL
Bus interfaceModbus RTU
ClassificationFor DC charging stations
Enclosure designDistribution board
IMD typeAC, AC/DC, DC
Nominal voltage IT systemAC 0 - 230 V, AC 0 - 690 (Coupling device) V, DC 0 - 230 V, DC 0 - 1000 (Coupling device) V
Response value1 - 500 kΩ
Response value typeAdjustable
Width52,5 mm
TypeRN 5897/321
Earth fault indicatorYes
Variant
Alarm value1 - 500 kOhm
Auxiliary voltageAC/DC 100 - 230 V
Contact equipping2 x 1 changeover contact
Prewarning value1 - 500 kOhm
Approvals and MarkingsUL-listed C/US


Product data sheet
Datasheet for Dold 0069400, EAN: 4030641694005

Questions & answers

What is the delivery time of Dold 0069400 RN5897.12/321/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k?

The article Dold 0069400 RN5897.12/321/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k is currently not in stock but has been backordered.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0069400 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0069400 RN5897.12/321/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k always at the best possible price. We can give you a discount of 2% on Dold 0069400 RN5897.12/321/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0069400 RN5897.12/321/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k we can offer you a price of 653,49 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0069400 RN5897.12/321/61 AC/DC100-230V insulation monitor 1k-500k
Dold 0069400 RN5897.12/321/61 AC/DC100-230V insulation monitor 1k-500k 1k-500k
684,28 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0069400 RN5897.12/321/61 AC/DC100-230V insulation monitor 1k-500k
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
6 + 7 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.