Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

Dold 0069399 RN5897.12/321/61 AC/DC24-60V insulation monitor 1k-500k 1k- 500k

Your rating:
Average rating
product review for Dold 0069399 RN5897.12/321/61 AC/DC24-60V insulation monitor 1k-500k 1k- 500k
( 4 / 5 ) 1 ratings
Dold 0069399
This image may differ from the desired article.
684,28 EUR
( 814,29 EUR incl. VAT )
≈ £573.43  |  ≈ $751.34
plus delivery charges: 55,00 €
On order · Delivery time approx. 20 workdaysinfo_outline
1x Dold 0069399 RN5897.12/321/61 AC/DC24-60V insulation monitor 1k-500k 1k- 500k
Datasheet:file_download Download
Lieske Part No.:1001703
Mfg Part No: 0069399
UPC/EAN: 4030641693992
Weight:0.335 kg
Type:RN5897.12/321/61 AC/DC24-60V
Graduated prices net
From piecesPrice per pieces
3653,49 EUR
6622,69 EUR
9591,90 EUR
12561,11 EUR

Product information for Dold 0069399:

The insulation monitor RN5897.12/321/61 AC/DC24-60V from Dold is a device of the VARIMETER IMD family for monitoring insulation in IT systems. It is designed for use in ungrounded AC, DC, and mixed AC/DC networks and is particularly suitable for DC charging stations for electric vehicles specified according to IEC/EN 61851-23:2014/AC:2016-06. The device monitors insulation even when the network is de-energized and detects both symmetrical and asymmetrical insulation faults. Parameterization is performed via a galvanically isolated Modbus RTU interface, through which all measured values, device statuses, and settings can be read and controlled.

Applications

The insulation monitor is universally applicable in IT systems with rated voltages up to AC 230 V and DC 230 V. With external pre-stage devices RL 5898 or RP 5898, it can be used for higher voltages up to AC 690 V or DC 1000 V. Main application areas include DC charging stations for electric vehicles, UPS systems, networks with frequency converters, battery networks, DC drives, hybrid and battery-powered vehicles, as well as mobile power generators. The devices are designed for network leakage capacitances up to 5 μF.

Functions and Equipment in Detail

The device features two independently adjustable trip thresholds, which can be used for pre-alarm and alarm functions. The adjustment range for both thresholds is between 1 kΩ and 500 kΩ. For each trip threshold, there is a dedicated changeover contact serving as a signaling relay. The relay operation mode (active or rest current principle) is selectable. A multicolored device status LED visually indicates the operating state in a user-friendly manner. An automatic self-test is performed after each full hour of operation, and a manual self-test is also possible. Alarm memory storage is selectable, and the measurement circuits L(+) and L(-) are monitored for wire break (can be disabled). The protective earth connections PE1/PE2 are also monitored for wire break, which cannot be disabled.

Technology Explained Simply

Insulation monitoring is performed according to IEC/EN 61557-8. The device measures the insulation resistance and responds when the set thresholds are undershot. The response time is maximum 1 second. The measurement is optimized even during network voltage fluctuations, as the network voltage is evaluated. The auxiliary voltage can range from AC/DC 24 to 60 V. The device is designed for an extended operating temperature range of -40 °C to +70 °C. The width is 52.5 mm, enabling installation in standard installation distributors. An external control input (X1, X2) allows connection of a combined test/reset button, with the additional option to pause the measurement function. The Modbus RTU interface is galvanically isolated, ensuring secure communication even in electrically noisy environments.

Compatibility and Accessories

The device is compatible with external pre-stage devices RL 5898 (for voltages up to AC 400 V / DC 500 V) and RP 5898 (for voltages up to AC 690 V / DC 1000 V). These extend the application range of the insulation monitor to higher voltages. Connections for the pre-stage device are made via terminals L(+), L(-), VSG1, VSG2. The devices are UL-listed C/US, confirming approval for use in North America.

Mounting and Installation

The insulation monitor is mounted in installation distributors. The width of 52.5 mm corresponds to the standard for DIN rail mounting. Connections are made via terminals: A1(+) and A2 for auxiliary voltage, L(+) and L(-) for the measurement circuit, PE1 and PE2 for protective earth, X1 and X2 for the external control input. Modbus signals are connected via terminals A and B. The tamper-proof transparent cover protects the device against unauthorized manipulation.

Operational Advantages

The device provides preventive fire and system protection through early detection of insulation faults. Setting trip thresholds and parameters is simple via Modbus, enabling centralized control and monitoring. The display of operating states via the multicolored LED simplifies diagnosis. The high operating temperature of up to +70 °C makes the device suitable for demanding environments. The galvanic isolation of the Modbus interface increases safety and immunity to interference. The combination of two adjustable trip thresholds enables a differentiated alarm strategy, e.g., pre-alarm for slight insulation degradation and alarm for critical values.

Technical data
ApprovalsUL
Bus interfaceModbus RTU
ClassificationFor DC charging stations
Enclosure designDistribution board
IMD typeAC, AC/DC, DC
Nominal voltage IT systemAC 0 - 230 V, AC 0 - 690 (Coupling device) V, DC 0 - 230 V, DC 0 - 1000 (Coupling device) V
Response value1 - 500 kΩ
Response value typeAdjustable
Width52,5 mm
TypeRN 5897/321
Earth fault indicatorYes
Variant
Alarm value1 - 500 kOhm
Auxiliary voltageAC/DC 24 - 60 V
Contact equipping2 x 1 changeover contact
Prewarning value1 - 500 kOhm
Approvals and MarkingsUL-listed C/US


Product data sheet
Datasheet for Dold 0069399, EAN: 4030641693992

Questions & answers

What is the delivery time of Dold 0069399 RN5897.12/321/61 AC/DC24-60V insulation monitor 1k-500k 1k- 500k?

The article Dold 0069399 RN5897.12/321/61 AC/DC24-60V insulation monitor 1k-500k 1k- 500k is currently not in stock but has been backordered.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0069399 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0069399 RN5897.12/321/61 AC/DC24-60V insulation monitor 1k-500k 1k- 500k always at the best possible price. We can give you a discount of 2% on Dold 0069399 RN5897.12/321/61 AC/DC24-60V insulation monitor 1k-500k 1k- 500k if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0069399 RN5897.12/321/61 AC/DC24-60V insulation monitor 1k-500k 1k- 500k we can offer you a price of 653,49 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0069399 RN5897.12/321/61 AC/DC24-60V insulation monitor 1k-500k
Dold 0069399 RN5897.12/321/61 AC/DC24-60V insulation monitor 1k-500k 1k- 500k
684,28 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0069399 RN5897.12/321/61 AC/DC24-60V insulation monitor 1k-500k
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
3 + 6 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.