Dold 0069322 UG9831.12 DC20-1000V UH=DC24V DC voltage relay
|
408,71 EUR |
|||||||||||
|
( 486,36 EUR incl. VAT ) ≈ £342.50 | ≈ $448.76 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1000853 | ||||||||||
| Mfg Part No: | 0069322 | ||||||||||
| UPC/EAN: | 4030641693220 | ||||||||||
| Weight: | 0.225 kg | ||||||||||
| Type: | UG9831.12 DC20-1000V UH=DC24V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0069322:
Applications
The relay is intended for monitoring DC power supply systems in industrial plants. It is used to detect impending failures early and enable preventive maintenance measures. This increases operational safety and ensures plant availability. Applications include systems with DC power supply, such as in automation technology, power engineering, or systems with battery storage.
Functions and Equipment in Detail
The device features two changeover contacts as output contacts, each providing a contact for the switching state and one for the rest state. The setting of the trigger values is done via rotary switches, which can be adjusted in steps of 10 V between 20 and 990 V. The built-in response delay prevents false alarms caused by short-term voltage fluctuations. Operational status indication is provided by LEDs: a green LED indicates the ready-to-operate state, a red LED displays error codes, and two yellow LEDs indicate activation of the output relays. Error codes are displayed by a specific number of blink pulses, for example, error code 1 indicates a parameterization error.
Technology Explained Simply
The relay measures the input voltage via terminals e+ and f and compares it with the set threshold values. When the voltage exceeds or falls below the specified range, the corresponding changeover contact is activated. The hysteresis ensures that the relay does not toggle rapidly around the threshold due to minor fluctuations. The internal overvoltage protection circuit with MOV (Metal Oxide Varistor) protects the device against transient voltage spikes. Voltage measurement is performed with an internal resistance of approximately 10 MΩ, ensuring high load independence. The auxiliary voltage must meet the requirements of SELV (safety extra-low voltage) or PELV (protective extra-low voltage).
Compatibility and Accessories
The relay is designed for use in single-phase DC networks. The terminal clamps are designed for connection with cables and wires. The device functions are independent of additional modules or external controls. Adjustment is done directly on the device via rotary switches, with a tamper-proof transparent cover providing adjustment protection. The devices are specified according to IEC/EN 60255-1, ensuring compliance with standards for measuring instruments in electrical power engineering.
Mounting and Installation
Mounting is done in an enclosure with a width of 22.5 mm. The terminals for auxiliary voltage (A1/A2) and voltage measurement (e+/f) are clearly labeled. The output relays (11-14 and 21-24) are intended for connection to external signaling or control devices. The devices are designed for use in industrial environments, with operating conditions such as temperature and humidity complying with specified limits. Installation is performed by securing the device in the enclosure and wiring the terminals according to the circuit diagram.
Advantages in Operation
The high repeatability and wide measurement range of DC 20 to 1000 V enable precise and reliable monitoring. Simple device adjustment via rotary switches and visual operational indication via LEDs facilitate commissioning and maintenance. Preventive maintenance is supported by early detection of voltage deviations, increasing productivity and preventing damage to downstream devices. The tamper-proof cover protects settings from unauthorized changes, which is particularly advantageous in safety-critical installations.
| Technical data | |
| 1- / 3-phase | 1 |
| Enclosure design | Switch cabinet |
| Nominal voltage max. | DC 1000 V |
| Output contacts | 2 x 1 C/O contacts |
| Width | 22,5 mm |
| Type | UG 9831 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | DC 24 V |
| Contact equipping | 2 x 1 changeover contact |
| Nominal voltage | DC 1000 V |
| Variant | For overvoltage or undervoltage monitoring |
Questions & answers
What is the delivery time of Dold 0069322 UG9831.12 DC20-1000V UH=DC24V DC voltage relay?
The article Dold 0069322 UG9831.12 DC20-1000V UH=DC24V DC voltage relay is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0069322 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0069322 UG9831.12 DC20-1000V UH=DC24V DC voltage relay always at the best possible price. We can give you a discount of 2% on Dold 0069322 UG9831.12 DC20-1000V UH=DC24V DC voltage relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0069322 UG9831.12 DC20-1000V UH=DC24V DC voltage relay we can offer you a price of 390,32 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.