Dold 0068565 ND5014/120 foldable current transformer
|
634,06 EUR |
|||||||||||
|
( 754,53 EUR incl. VAT ) ≈ £531.34 | ≈ $696.20 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 2121927 | ||||||||||
| Mfg Part No: | 0068565 | ||||||||||
| UPC/EAN: | 4030641685652 | ||||||||||
| Weight: | 1.5 kg | ||||||||||
| Type: | ND5014/120 | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0068565:
Applications
The ND5014/120 is used in systems where differential current measurement according to IEC/EN 62020 is required, for example in protection systems against electrical fault currents. It is designed for monitoring currents in the range of 10 mA to a maximum of 30 A. The application is in conjunction with the DOLD differential current monitors IL 5882 and SL 5882, where all current-carrying conductors — except the protective earth conductor PE — are routed through the transformer. This is typical for fault current protection systems in electrical installations.
Functions and Equipment in Detail
The transformer features a passage opening with an inner diameter of 119 mm, making it suitable for larger conductor cross-sections. Mounting is vertical or horizontal on a DIN rail using the included plinth. The conductor connection terminals are equipped with spring pressure connection (Push-In technology), enabling quick and secure wiring. The stripping length is 6 mm, and the permissible conductor cross-sections range from 0.2 mm² to 2.5 mm² for rigid and flexible conductors (corresponding to AWG 24 to 12).
Technology Explained Simply
The hinged current transformer operates on the principle of a current transformer, where the primary current (up to 10 A here) is transformed into a secondary, smaller current (nominal transformation ratio 500:1). This secondary current is transmitted to the differential current monitor, which determines the difference between the currents in the individual conductors. If deviations from the norm occur (e.g. fault currents), the monitor can trigger appropriate protective measures. The accuracy class of the transformer is 3, which is sufficient for use in protection systems. The insulation coordination is according to IEC 61869-1, with a maximum voltage of AC 720 V and a rated impulse withstand voltage of 8 kV at pollution degree 3.
Compatibility and Accessories
The ND5014/120 is approved exclusively for operation with the DOLD differential current monitors IL 5882 and SL 5882. The connection is made via terminals i and k, which are duplicated to ensure a secure connection to the monitor. Mounting is done on an included plinth designed for the DIN rail.
Mounting and Installation
Mounting is done by opening the transformer, inserting the current-carrying conductors into the passage opening, and closing the cover. The terminals are equipped with Push-In technology, allowing wiring without tools. The maximum actuation force is 40 N. When using screw fastening, care must be taken to avoid excessive forces on the mounting feet, as these only hold the transformer itself and do not absorb forces from the conductors passing through. The conductors must be freely routed through the transformer to ensure correct positioning.
Advantages in Operation
The ND5014/120 offers easy mounting and retrofitting in existing systems, as no conductors need to be cut. The hinged cover protects the terminal block and prevents accidental disconnection of wiring. DIN rail mounting allows flexible positioning, and screw fastening provides additional stability. Compliance with standards IEC 61869-1 and IEC 61869-8, as well as approval for differential current measurement according to IEC/EN 62020, ensures reliability and safety in operation. The ambient temperature range is -40 °C to +80 °C, enabling broad application in various environments. The flammability class V0 according to UL94 indicates the high safety of the material.
| Technical data | |
| Diameter | 49 mm, 79 mm, 119 mm |
| For relay type | IL 5882, SL 5882 |
| Type | ND 5014 |
| Variant | |
| Variant | 119 mm inner diameter |
Questions & answers
What is the delivery time of Dold 0068565 ND5014/120 foldable current transformer ?
The article Dold 0068565 ND5014/120 foldable current transformer is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0068565 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0068565 ND5014/120 foldable current transformer always at the best possible price. We can give you a discount of 2% on Dold 0068565 ND5014/120 foldable current transformer if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0068565 ND5014/120 foldable current transformer we can offer you a price of 624,55 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.