Dold 0068565, EAN: 4030641685652

Dold 0068565 ND5014/120 current transformer

Industrial Material > Industrial relays and contactors > Switching units / measuring, control relay

Dold 0068565 ND5014/120 current transformer

Lieske Part No. 2121927
Mfg Part No 0068565
EAN-Code 4030641685652
Manufacturer Dold
Here only 634,06 EUR
754,53 EUR incl. VAT

Further information for Dold 0068565 ND5014/120 current transformer

Technical data
Diameter49 mm, 79 mm, 119 mm
For relay typeIL 5882, SL 5882
TypeND 5014
Variant
Variant119 mm inner diameter
The ND5014/120 hinged current transformer from Dold is a measuring current transformer for differential current measurement in conjunction with the differential current monitors IL 5882 and SL 5882. It is designed for monitoring alternating and pulsating direct currents and is specifically designed for mounting on current-carrying conductors without disconnecting the conductors. The hinged design enables easy installation, especially for retrofits in existing systems. The transformer is intended for use in industrial and technical systems where precise fault current monitoring is required.

Applications

The ND5014/120 is used in systems where differential current measurement according to IEC/EN 62020 is required, for example in protection systems against electrical fault currents. It is designed for monitoring currents in the range of 10 mA to a maximum of 30 A. The application is in conjunction with the DOLD differential current monitors IL 5882 and SL 5882, where all current-carrying conductors — except the protective earth conductor PE — are routed through the transformer. This is typical for fault current protection systems in electrical installations.

Functions and Equipment in Detail

The transformer features a passage opening with an inner diameter of 119 mm, making it suitable for larger conductor cross-sections. Mounting is vertical or horizontal on a DIN rail using the included plinth. The conductor connection terminals are equipped with spring pressure connection (Push-In technology), enabling quick and secure wiring. The stripping length is 6 mm, and the permissible conductor cross-sections range from 0.2 mm² to 2.5 mm² for rigid and flexible conductors (corresponding to AWG 24 to 12).

Technology Explained Simply

The hinged current transformer operates on the principle of a current transformer, where the primary current (up to 10 A here) is transformed into a secondary, smaller current (nominal transformation ratio 500:1). This secondary current is transmitted to the differential current monitor, which determines the difference between the currents in the individual conductors. If deviations from the norm occur (e.g. fault currents), the monitor can trigger appropriate protective measures. The accuracy class of the transformer is 3, which is sufficient for use in protection systems. The insulation coordination is according to IEC 61869-1, with a maximum voltage of AC 720 V and a rated impulse withstand voltage of 8 kV at pollution degree 3.

Compatibility and Accessories

The ND5014/120 is approved exclusively for operation with the DOLD differential current monitors IL 5882 and SL 5882. The connection is made via terminals i and k, which are duplicated to ensure a secure connection to the monitor. Mounting is done on an included plinth designed for the DIN rail.

Mounting and Installation

Mounting is done by opening the transformer, inserting the current-carrying conductors into the passage opening, and closing the cover. The terminals are equipped with Push-In technology, allowing wiring without tools. The maximum actuation force is 40 N. When using screw fastening, care must be taken to avoid excessive forces on the mounting feet, as these only hold the transformer itself and do not absorb forces from the conductors passing through. The conductors must be freely routed through the transformer to ensure correct positioning.

Advantages in Operation

The ND5014/120 offers easy mounting and retrofitting in existing systems, as no conductors need to be cut. The hinged cover protects the terminal block and prevents accidental disconnection of wiring. DIN rail mounting allows flexible positioning, and screw fastening provides additional stability. Compliance with standards IEC 61869-1 and IEC 61869-8, as well as approval for differential current measurement according to IEC/EN 62020, ensures reliability and safety in operation. The ambient temperature range is -40 °C to +80 °C, enabling broad application in various environments. The flammability class V0 according to UL94 indicates the high safety of the material.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/2121927