Dold 0068220 RR5886 AC/DC85-230V test current generator
|
1.108,54 EUR |
|||||||||||
|
( 1.319,16 EUR incl. VAT ) ≈ £928.96 | ≈ $1,217.18 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1002094 | ||||||||||
| Mfg Part No: | 0068220 | ||||||||||
| UPC/EAN: | 4030641682200 | ||||||||||
| Weight: | 0.33 kg | ||||||||||
| Type: | RR5886 AC/DC85-230V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0068220:
Applications
The RR 5886 is used in installations where high operational reliability and availability of power supply are required. These include industrial plants, shipbuilding, plant engineering, and photovoltaic systems. Insulation fault detection is performed in IT systems with nominal voltages of DC, AC, and 3AC in the range of 24 to 455 V. The application is particularly suited for networks where both alternating and direct current components are present simultaneously.
Functions and Equipment in Detail
The device generates positive and negative test currents used for monitoring DC networks and mixed AC/DC networks. The external current transformers operate independently and are connected to the measurement channels of the insulation fault detector RR 5887, where they are calibrated. The test current output can be manually initiated via a button or externally controlled via terminal connections (Y1, Y2). Shorting terminals Y1-Y2 disables the start/stop button. The test current output depends on the bus mode, which is controlled via the RS-485 bus connection.
Technology Explained Simply
The RR 5886 operates in master/slave mode and enables synchronization of test current evaluation via an RS-485 bus connection. Multiple insulation fault detectors can be connected via this bus, increasing the number of measurement channels. This allows for more precise localization of insulation faults in extensive networks. The Modbus RTU interface is used for controlling insulation fault detection and reading measured insulation fault currents. Status output is provided via an external switching output (terminals G, H). Device indicators include a green LED ON" (when operating voltage is applied), a yellow LED "BUS (RS-485 bus activity), and yellow LEDs for positive and negative test current pulse output.
Compatibility and Accessories
The test current generator RR 5886 is specifically designed for use with the insulation fault detector RR 5887. The interaction between both devices follows DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1). Insulation coordination is performed according to IEC 60664-1. External control via an insulation monitor is possible, facilitating integration into existing monitoring systems.
Mounting and Installation
Mounting is performed in standard control panels with a width of 105 mm. Connections are made via terminals: A1(+), A2 for auxiliary supply (AC/DC), L1(+), L2(-), L3, PE for IT network voltage connections, SH, GND, Rb, B, A, Ra for RS-485 bus connection (galvanically isolated), Y1, Y2 for switching input to control test current, and G, H for switching output for status indication.
Operational Advantages
By enabling early detection and localization of insulation faults, the RR 5886 allows for quick and targeted troubleshooting. The two alarm levels support timely recognition of dangerous insulation conditions. Intuitive operation through automatic calibration and clear adjustment elements reduces operator effort. The universal auxiliary voltage range of AC/DC 85 to 230 V increases flexibility during installation in various plant environments. Network operational safety and high availability are ensured through continuous monitoring and rapid fault localization.
| Technical data | |
| Bus interface | Modbus RTU, RS-485 |
| Nominal voltage IT system | DC, AC, 3AC 24 - 455 V |
| Operating mode | Master / Slave |
| Width | 105 mm |
| Type | RR 5886 |
| Variant | |
| Auxiliary voltage | AC/DC 85 - 230 V |
| Variant | For industrial plants |
Questions & answers
What is the delivery time of Dold 0068220 RR5886 AC/DC85-230V test current generator?
The article Dold 0068220 RR5886 AC/DC85-230V test current generator is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0068220 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0068220 RR5886 AC/DC85-230V test current generator always at the best possible price. We can give you a discount of 2% on Dold 0068220 RR5886 AC/DC85-230V test current generator if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 2 pieces of Dold 0068220 RR5886 AC/DC85-230V test current generator we can offer you a price of 1.058,66 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.