Product information for Dold 0067692:
Applications
The device is intended for use in industrial plants, shipbuilding, plant engineering, and photovoltaic installations. Special emphasis is placed on its use in areas used for medical purposes, where high operational safety and availability of power supply are required. The ability to detect insulation faults early contributes to avoiding failures and ensuring the functionality of critical systems.
Functions and Equipment in Detail
The RR5887.12/011 features 8 measurement channels, each of which can connect an external current transformer. The number of measurement channels can be increased by connecting multiple devices via an RS-485 bus connection, thereby enabling more precise fault location in extensive networks. The device operates in slave mode, meaning it functions within a network of multiple devices under the control of a master. Communication takes place via the RS-485 bus interface, which can optionally also be used for Modbus RTU. This allows integration into existing fieldbus systems and central evaluation of measurement data.
Technology Explained Simply
The operation is based on injecting a test current into the network via the RR 5886, while the RR 5887 evaluates this current. The external current transformers detect the test current at various points in the network and transmit the signals to the measurement channels of the RR 5887. The device recognizes two alarm levels: a pre-alarm when the insulation fault current exceeds 1 mA, and an alarm when the current exceeds 5 mA. These levels enable a step-by-step response to deteriorating insulation conditions. Indication is provided via LEDs – green for operating voltage, yellow for pre-alarm, and red for alarm. A yellow LED labeled BUS indicates activity on the RS-485 connection.
Compatibility and Accessories
The device is specifically designed for use with the test current generator RR 5886 and complies with standards DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1). Insulation coordination is performed according to IEC 60664-1. The nominal voltage of the IT system can be DC, AC, or 3AC in the range of 24 to 455 V. The auxiliary voltage for the device itself is in the range of AC/DC 85 to 230 V. The width is 105 mm, enabling installation in standard control panels.
Mounting and Installation
Installation is carried out via terminal connections. The terminals are designated for auxiliary voltage (A1, A2), current transformers (K1–K4/I1–I4), RS-485 bus (SH, GND, Rb, B, A, Ra), switching output (G, H), and alarm relays (11–14, 21–24). A switching input (X1, X2) allows setting the memory behavior for alarm states, which can be activated via a wire bridge or an external control input with a maximum of 24 V DC. The function is active-low, meaning alarm memory is activated when a low level is applied.
Advantages in Operation
Early detection and localization of insulation faults enable targeted and rapid correction, increasing operational safety. Simple operation via clear adjustment elements and automatic calibration reduces maintenance effort. Fault memory allows documentation of alarm states, which is helpful for tracing malfunctions. The integrated alarm relays (two changeover contacts each for pre-alarm and alarm) enable control of external signaling devices or control systems. Galvanic isolation of the RS-485 bus connection increases system immunity to interference and safety.
| Technical data | |
| Bus interface | Modbus RTU, RS-485 |
| Nominal voltage IT system | DC, AC, 3AC 24 - 455 V |
| Operating mode | Slave |
| Width | 105 mm |
| Type | RR 5887 |
| Failure storage | |
| Variant | |
| Auxiliary voltage | AC/DC 85 - 230 V |
| Contact equipping | 2 changeover contacts |
| Variant | For rooms for medical purposes. 8 measuring channels |
Questions & answers
What is the delivery time of Dold 0067692 RR5887.12/011 AC/DC85-230V insulation fault detector?
The article Dold 0067692 RR5887.12/011 AC/DC85-230V insulation fault detector is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0067692 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0067692 RR5887.12/011 AC/DC85-230V insulation fault detector always at the best possible price. We can give you a discount of 2% on Dold 0067692 RR5887.12/011 AC/DC85-230V insulation fault detector if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0067692 RR5887.12/011 AC/DC85-230V insulation fault detector we can offer you a price of 790,52 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.