Dold 0067691 RR5887.12/010 AC/DC85-230V insulation fault locator
|
462,96 EUR |
|||||||||||
|
( 550,92 EUR incl. VAT ) ≈ £387.96 | ≈ $508.33 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001647 | ||||||||||
| Mfg Part No: | 0067691 | ||||||||||
| UPC/EAN: | 4030641676919 | ||||||||||
| Weight: | 0.355 kg | ||||||||||
| Type: | RR5887.12/010 AC/DC85-230V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0067691:
Applications
This device is designed for use in industrial plants, shipbuilding, plant engineering, and photovoltaic installations. It is especially relevant in medical facilities, where interruption of power supply can be critical. The ability to detect and locate insulation faults early contributes to avoiding failures and increasing system availability. The application is in IT systems with nominal voltages of DC, AC, and 3AC in the range of 24 to 455 V.
Functions and Equipment in Detail
The device supports two alarm levels: a pre-alarm for insulation fault currents above 1 mA and an alarm for currents above 5 mA. These levels allow for a step-by-step response to deteriorating insulation conditions. Status indication is provided via LED indicators: green LED for operating voltage, yellow LEDs for pre-alarm per channel, red LEDs for alarm per channel, and a yellow BUS-LED for RS-485 bus activity. A summary alarm relay with 2 changeover contacts enables output of pre-alarm and alarm states. A push-button is used for manual reset of alarms as well as for testing and calibration of the current transformers.
Technology Explained Simply
The device operates as a slave, meaning it communicates within a network via an RS-485 bus connection with other devices. The bus interface supports Modbus RTU, enabling integration into existing fieldbus systems. The auxiliary voltage is AC/DC 85 to 230 V, allowing universal adaptation to various power supply networks. The width of 105 mm allows mounting in standard control panels. Fault memory can be activated via a switching input (terminals X1, X2), which can be controlled either by a wire bridge or by an external device with a maximum of 24 V DC. When fault memory is activated, alarm states are retained after an insulation fault detection cycle.
Compatibility and Accessories
The device is specifically designed for use with the test current generator RR 5886, which injects the necessary test currents into the network. The cooperation follows DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1). Insulation coordination is performed according to IEC 60664-1. The number of measurement channels can be extended by linking multiple RR 5887 devices via RS-485, thereby improving fault localization in extensive networks.
Mounting and Installation
Mounting is done in standard control panels with a width of 105 mm. The connection terminals are clearly labeled: A1/A2 for auxiliary voltage, K1 to K4/I1 to I4 for current transformers, SH, GND, Rb, B, A, Ra for RS-485 bus connection, X1/X2 for switching input, G/H for status output, and 11/12/14 as well as 21/22/24 for the alarm relay. Wiring is done according to the circuit diagram in the datasheet.
Advantages in Operation
The combination of automatic balancing function, clear operation, and the ability to store alarm states enables quick and targeted fault correction. Integration into Modbus networks and the scalability of measurement channels through additional devices increase the flexibility and scalability of the system. Operational safety is enhanced by early detection of insulation faults and clear visual indication of fault states.
| Technical data | |
| Bus interface | Modbus RTU, RS-485 |
| Nominal voltage IT system | DC, AC, 3AC 24 - 455 V |
| Operating mode | Slave |
| Width | 105 mm |
| Type | RR 5887 |
| Failure storage | |
| Variant | |
| Auxiliary voltage | AC/DC 85 - 230 V |
| Contact equipping | 2 changeover contacts |
| Variant | For rooms for medical purposes. 4 measuring channels |
Questions & answers
What is the delivery time of Dold 0067691 RR5887.12/010 AC/DC85-230V insulation fault locator?
The article Dold 0067691 RR5887.12/010 AC/DC85-230V insulation fault locator is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0067691 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0067691 RR5887.12/010 AC/DC85-230V insulation fault locator always at the best possible price. We can give you a discount of 2% on Dold 0067691 RR5887.12/010 AC/DC85-230V insulation fault locator if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0067691 RR5887.12/010 AC/DC85-230V insulation fault locator we can offer you a price of 442,13 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.



