Dold 0067065 ND5016/070 differential current transformer
|
148,49 EUR |
|||||||||||
|
( 176,70 EUR incl. VAT ) ≈ £124.43 | ≈ $163.04 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1000864 | ||||||||||
| Mfg Part No: | 0067065 | ||||||||||
| UPC/EAN: | 4030641670658 | ||||||||||
| Weight: | 0.123 kg | ||||||||||
| Type: | ND5016/070 | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0067065:
Applications
The ND5016/070 is used for preventive installation monitoring in industrial and commercial electrical systems. It is suitable for installations where immediate disconnection upon insulation faults is not required, but early warning is sufficient to initiate maintenance measures. The application is particularly intended for earthed networks, where detection of insulation degradation contributes to preventing fires and system failures. Installation is either on DIN rail – horizontally or vertically – or by screw mounting, allowing flexible integration into existing enclosures.
Functions and Equipment in Detail
The transformer features an inner diameter of 70 mm, suitable for passing multiple conductors. It is part of a system consisting of the transformer and a differential current monitor, with measurement carried out via terminals i and k. The operation is based on the principle of differential current measurement: in a fault-free state, the sum of all currents is zero, so no voltage is induced in the transformer. In case of an insulation fault, a fault current flows to earth, creating a current imbalance and inducing a measurable voltage in the transformer. This voltage is detected and evaluated by the differential current monitor. The transformer supports detection of alternating and pulsating direct currents (Type A according to IEC/TR 60755) and is designed for frequencies from 20 to 2000 Hz.
Technology Explained Simply
The ND5016/070 operates on the residual current principle, where the output relay is not activated in the event of a fault, but only an indication is given. The measurement is performed via an external transformer that encircles the conductors of the monitored circuit. The induced voltage is evaluated by the differential current monitor (IL 5882 or SL 5882), which displays the status via LED indicators (green for auxiliary voltage, red for pre-warning and alarm). The wire break detection ensures that a broken conductor in the transformer circuit is immediately detected to avoid false alarms. The response time is short, enabling rapid fault detection; however, with pulsating fault currents and a time delay of 0 s, the output relay may flicker, which can be prevented by setting a short delay.
Compatibility and Accessories
The differential current transformer ND5016/070 is specifically developed for use with the differential current monitors IL 5882 and SL 5882. These devices are available in two housing types: IL 5882 with 63 mm depth and bottom-mounted terminals for installation and industrial distributors according to DIN 43880, and SL 5882 with 100 mm depth and top-mounted terminals for enclosures with mounting plate. The transformers are also compatible with other models such as ND 5019 or the hinged current transformer ND 5014, with the exact selection depending on the specific installation and the number of conductors.
Mounting and Installation
Mounting is either on DIN rail – horizontally or vertically – or by screw fastening. Installation requires passing all conductors to be monitored (excluding PE) through the inner diameter of the transformer. Connection to the differential current monitor is made via terminals i and k. Positioning must ensure that all relevant conductors are captured and the transformer is not mechanically stressed. Adherence to mounting instructions is crucial for the reliability of the measurement.
Advantages in Operation
The use of the ND5016/070 enables early detection of insulation faults, increasing system availability and enabling preventive maintenance. Status indication is provided via LED indicators, directly informing the operator. Wire break detection prevents false alarms, and the short response time ensures rapid fault detection. Compatibility with various differential current monitors and flexible mounting options increase the versatility of the transformer in different application scenarios. Compliance with standard IEC/EN 62020 ensures the reliability and safety of the system.
| Technical data | |
| Diameter | 24 mm, 35 mm, 70 mm |
| For relay type | IL 5882, SL 5882 |
| Type | ND 5016 |
| Variant | |
| Variant | 70 mm inner diameter |
Questions & answers
What is the delivery time of Dold 0067065 ND5016/070 differential current transformer?
The article Dold 0067065 ND5016/070 differential current transformer is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0067065 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0067065 ND5016/070 differential current transformer always at the best possible price. We can give you a discount of 2% on Dold 0067065 ND5016/070 differential current transformer if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0067065 ND5016/070 differential current transformer we can offer you a price of 141,81 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.