Dold 0067065 ND5016/070 differential current transformer

Dold 0067065 ND5016/070 differential current transformer

Lieske Part No. 1000864
Mfg Part No 0067065
EAN-Code 4030641670658
Manufacturer Dold
Here only 148,49 EUR
176,70 EUR incl. VAT

Further information for Dold 0067065 ND5016/070 differential current transformer

Technical data
Diameter24 mm, 35 mm, 70 mm
For relay typeIL 5882, SL 5882
TypeND 5016
Variant
Variant70 mm inner diameter
The Dold differential current transformer ND5016/070 is an external measuring transformer for monitoring electrical installations in earthed networks. It is used together with the differential current monitors IL 5882 and SL 5882 to detect insulation faults at an early stage without interrupting operational continuity. The transformer is specifically designed for use in industrial and installation distributors and enables continuous monitoring of lines by passing all current conductors (excluding protective earth conductor PE) through its inner diameter. The measurement is carried out via the induced voltage in the transformer, which is generated when an imbalance in current – i.e. a fault current – occurs. This fault current is detected and evaluated by the connected differential current monitor.

Applications

The ND5016/070 is used for preventive installation monitoring in industrial and commercial electrical systems. It is suitable for installations where immediate disconnection upon insulation faults is not required, but early warning is sufficient to initiate maintenance measures. The application is particularly intended for earthed networks, where detection of insulation degradation contributes to preventing fires and system failures. Installation is either on DIN rail – horizontally or vertically – or by screw mounting, allowing flexible integration into existing enclosures.

Functions and Equipment in Detail

The transformer features an inner diameter of 70 mm, suitable for passing multiple conductors. It is part of a system consisting of the transformer and a differential current monitor, with measurement carried out via terminals i and k. The operation is based on the principle of differential current measurement: in a fault-free state, the sum of all currents is zero, so no voltage is induced in the transformer. In case of an insulation fault, a fault current flows to earth, creating a current imbalance and inducing a measurable voltage in the transformer. This voltage is detected and evaluated by the differential current monitor. The transformer supports detection of alternating and pulsating direct currents (Type A according to IEC/TR 60755) and is designed for frequencies from 20 to 2000 Hz.

Technology Explained Simply

The ND5016/070 operates on the residual current principle, where the output relay is not activated in the event of a fault, but only an indication is given. The measurement is performed via an external transformer that encircles the conductors of the monitored circuit. The induced voltage is evaluated by the differential current monitor (IL 5882 or SL 5882), which displays the status via LED indicators (green for auxiliary voltage, red for pre-warning and alarm). The wire break detection ensures that a broken conductor in the transformer circuit is immediately detected to avoid false alarms. The response time is short, enabling rapid fault detection; however, with pulsating fault currents and a time delay of 0 s, the output relay may flicker, which can be prevented by setting a short delay.

Compatibility and Accessories

The differential current transformer ND5016/070 is specifically developed for use with the differential current monitors IL 5882 and SL 5882. These devices are available in two housing types: IL 5882 with 63 mm depth and bottom-mounted terminals for installation and industrial distributors according to DIN 43880, and SL 5882 with 100 mm depth and top-mounted terminals for enclosures with mounting plate. The transformers are also compatible with other models such as ND 5019 or the hinged current transformer ND 5014, with the exact selection depending on the specific installation and the number of conductors.

Mounting and Installation

Mounting is either on DIN rail – horizontally or vertically – or by screw fastening. Installation requires passing all conductors to be monitored (excluding PE) through the inner diameter of the transformer. Connection to the differential current monitor is made via terminals i and k. Positioning must ensure that all relevant conductors are captured and the transformer is not mechanically stressed. Adherence to mounting instructions is crucial for the reliability of the measurement.

Advantages in Operation

The use of the ND5016/070 enables early detection of insulation faults, increasing system availability and enabling preventive maintenance. Status indication is provided via LED indicators, directly informing the operator. Wire break detection prevents false alarms, and the short response time ensures rapid fault detection. Compatibility with various differential current monitors and flexible mounting options increase the versatility of the transformer in different application scenarios. Compliance with standard IEC/EN 62020 ensures the reliability and safety of the system.