Product information for Dold 0066451:
Applications
This differential current monitor is intended for use in industrial and technical installations, particularly in systems with mixed AC/DC networks. It serves to detect insulation faults early, which could otherwise lead to fire or equipment damage. The device is used in installation distributors, with a width of 52.5 mm allowing integration into standard control panels. The devices are specified according to IEC/EN 62020 and VDE 0663, ensuring compliance with international safety and functional standards.
Functions and Equipment in Detail
The device features four adjustable measurement ranges from 10 mA to 3 A (0.01–3 A), set via rotary switches. The settings are protected against unauthorized changes by a tamper-proof transparent cover. Upon fault detection, a pre-alarm is triggered, signaled via a separate changeover contact and an LED indicator. A second changeover contact is used for alarm notification, also with LED indication. The LED bar displays the current differential current value, enabling visual monitoring of the operating status. A test button allows functional testing, while a reset button is used to clear the indicators after fault resolution.
Technology Explained Simply
The RN5883 detects differential currents indicating insulation faults via an external current transformer. Measurement is performed using either the residual current or operating current principle, with selection depending on the application. The response delay (0–10 s) prevents false alarms caused by short-term disturbances. Wire break detection ensures that a broken measurement circuit is recognized, avoiding misinterpretations. The relay contacts are configured as changeover contacts, allowing them to be used for various control and signaling tasks.
Compatibility and Accessories
The device is specifically designed for use with current transformers ND5015/024 and ND5015/035. It is available without an analog output, enabling use in pure signaling applications. Certifications UL-listed C/US and CCC confirm compliance with respective safety standards in the USA and China. The devices are designed for use in installation distributors, with a width of 52.5 mm enabling standard mounting in control panels.
Mounting and Installation
Mounting is performed in installation distributors. The connection terminals are designed for connection to external current transformers and auxiliary power supply. Settings for measurement range, time delay, and threshold values are adjusted via mechanical rotary switches. The tamper-proof transparent cover protects the settings from unauthorized changes. The devices are designed for use in earthed networks, with auxiliary voltage required in the range AC/DC 80–230 V.
Operational Advantages
The RN5883 enables early fault detection, increasing system availability and avoiding costly downtimes. Visual indication via LED bar and status LEDs provides a quick overview of the operating status. Separate relay contacts for pre-alarm and alarm allow differentiated responses to fault conditions. Wire break detection and test function enhance system reliability. Use in AC/DC networks expands the application range compared to pure AC systems.
| Technical data | |
| Adjustable measuring ranges | 0,01 - 3 A |
| Approvals | UL |
| Classification | Type B (AC, DC even and pulsating) |
| Enclosure design | Distribution board |
| Type of voltage | AC, DC |
| Width | 52,5 mm |
| Type | RN 5883 |
| Broken conductor detection | |
| Clear key | |
| Operate delay | |
| Relay contact / output | |
| Test key | |
| Variant | |
| Auxiliary voltage | AC/DC 80 - 230 V |
| Contact equipping | 1 changeover contact for prewarning, 1 changeover contact for alarm |
| Measuring range | 10 - 3000 mA |
| Time delay | 0 - 10 s |
| Approvals and Markings | UL-listed C/US, CCC |
| Variant | For current transformer ND5015/024, ND5015/035. Without analogue output |
Questions & answers
What is the delivery time of Dold 0066451 RN5883.12/61 AC/DC80-230V 10-3000mA residual current monitor type B 0-10s?
The article Dold 0066451 RN5883.12/61 AC/DC80-230V 10-3000mA residual current monitor type B 0-10s is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0066451 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0066451 RN5883.12/61 AC/DC80-230V 10-3000mA residual current monitor type B 0-10s always at the best possible price. We can give you a discount of 2% on Dold 0066451 RN5883.12/61 AC/DC80-230V 10-3000mA residual current monitor type B 0-10s if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0066451 RN5883.12/61 AC/DC80-230V 10-3000mA residual current monitor type B 0-10s we can offer you a price of 545,61 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.