Product information for Dold 0065981:
Applications
The device is designed for use in industrial control systems, automation systems, and plants for heating, motor, valve, and lighting control. Due to its high switching frequency and noiseless operation, it is especially suitable for installations where mechanical relays or contactors would cause disturbance noises due to their mechanical movements. The load voltage up to 480 V and the load current up to 50 A (at 40 °C ambient temperature) enable use in medium to high power requirements.
Functions and equipment in detail
The solid-state contactor features protection circuitry using varistors, which protects against transient overvoltages and increases the device's lifespan. The control is digital via DC voltage, allowing integration into modern control systems such as PLCs or SPS systems. The on and off delay is each ≤ 1 ms plus 1/2 cycle of the mains voltage, with the 1/2 cycle being omitted in the instant-switching variant. The minimum load current is AC 40 mA, ensuring reliable switching even at low loads.
Technology explained simply
The device operates as a solid-state contactor, where no moving contacts are present, but electronic semiconductors (usually thyristors or triacs) close and open the current circuit. This eliminates mechanical wear, resulting in high lifespan and reliability. The zero-voltage switching function reduces electromagnetic compatibility (EMC) and prevents sparking. The peak blocking voltage is ± 1200 Vp, ensuring high insulation strength against transient voltage peaks. The power loss is calculated using the formula P = 1,2 [V] x Ieff. [A] / k [W], where k is the form factor (for sinusoidal current, k = 1,11).
Compatibility and accessories
The device is compliant with IEC/EN 60947-4-2 and IEC/EN 60947-4-3 and carries the UL-listed C/US approval, enabling use in the USA and Canada. It is available in various widths (22.5 mm, 45 mm, 90 mm) and can be clipped onto a DIN rail, enabling easy installation in enclosures. The load voltage ranges include AC 24–240 V and AC 24–480 V, with a frequency of 50/60 Hz. For protection of the semiconductors, semiconductor fuses (e.g. cylindrical fuse 10 x 38) are required, which are dimensioned differently depending on the configuration (1-, 2- or 3-pole). The limit load integral values (I²t) are specified for the 2-pole variant as 1800 A²s at 2 s, enabling high surge current resistance for connection to inductive loads such as motors or transformers.
Mounting and installation
Mounting is done by clipping onto a DIN rail, with the installation position required to be horizontal. The ambient temperature is 0 to 40 °C, with current derating required at 40 °C. The maximum device temperature is 60 °C, with current derating varying depending on width and heatsink design. The storage temperature is between -20 and +80 °C. The clearance and creepage distances correspond to pollution degree 3 and a rated impulse voltage of 4 kV according to IEC 60664-1.
Advantages in operation
Due to noiseless switching and high lifespan without mechanical wear, the device is particularly suitable for applications requiring high operational reliability and low maintenance. The EMC compliance according to IEC/EN 61000-6-4 and -6-1, as well as protection circuitry using varistors, increases reliability in electrically disturbed environments. The DIN rail mounting enables quick and flexible installation in existing enclosures. The zero-voltage switching function reduces load stress and extends the lifespan of motors and heating elements.
More spare projector bulbs for your Sanyo Beamer
| Technical data | |
| Approvals | UL |
| Load current up to | 50 A |
| Load voltage up to | AC 480 V |
| Number of poles | 1-pole, 2-pole, 3-pole |
| On/Off Input Control | DC |
| Width | 22,5 mm, 45 mm, 90 mm |
| Type | BF 9250/_ _8 |
| Variant | |
| Auxiliary voltage | DC 7 - 32 V |
| Contact equipping | without signal contact |
| Load current | 2 x AC 25 A |
| Load voltage | AC 24 - 480 V |
| Semiconductor output | 2-pole |
| Approvals and Markings | UL-listed C/US |
| Variant | Switching at zero crossing. With high I2t value |
Questions & answers
What is the delivery time of Dold 0065981 BF9250.92/108 UH=DC7-32V 2xAC25A semiconductor contactor AC24-480V?
The article Dold 0065981 BF9250.92/108 UH=DC7-32V 2xAC25A semiconductor contactor AC24-480V is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0065981 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0065981 BF9250.92/108 UH=DC7-32V 2xAC25A semiconductor contactor AC24-480V always at the best possible price. We can give you a discount of 2% on Dold 0065981 BF9250.92/108 UH=DC7-32V 2xAC25A semiconductor contactor AC24-480V if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0065981 BF9250.92/108 UH=DC7-32V 2xAC25A semiconductor contactor AC24-480V we can offer you a price of 266,33 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.