Dold 0065944 MK9054N.12/110 AC25-250V Tv=0-20S voltage relay AC/DC80-230V Ta=0.1-20S
|
291,36 EUR |
|||||||||||
|
( 346,72 EUR incl. VAT ) ≈ £244.16 | ≈ $319.91 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1002180 | ||||||||||
| Mfg Part No: | 0065944 | ||||||||||
| UPC/EAN: | 4030641659448 | ||||||||||
| Weight: | 0.195 kg | ||||||||||
| Type: | MK9054N.12/110 AC25-250V Tv=0-20S | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0065944:
Applications
This relay is designed for continuous voltage monitoring in the range AC 25–250 V. It is used for early detection of voltage fluctuations to prevent damage to electrical systems and equipment. Applications are particularly in industrial environments where high operational safety and reliability are required. The integrated switching delay of 0 to 20 seconds enables differentiated response to short-term voltage spikes, avoiding false tripping. The pickup delay of 0.1 to 20 seconds ensures controlled response after reaching the setpoint.
Functions and equipment in detail
The device features 2 changeover contacts as output contacts, which can be used to control auxiliary circuits or warning signals. The contacts are rated for a maximum nominal voltage of AC 500 V and DC 450 V. The auxiliary voltage is AC/DC 80–230 V, allowing flexible use in various network voltage conditions. An integrated remote potentiometer enables remote control of the pickup value, although the measurement circuit and remote potentiometer are not galvanically isolated. Terminal markings include auxiliary voltage (A1, A2), voltage input (e, f), and contacts (11, 12, 14 and 21, 22, 24). Indication is provided by a green LED for operational readiness and a yellow LED for contact status.
Technology explained simply
The relay measures the arithmetic mean of the rectified measurement voltage. For AC voltages, the device is calibrated to the RMS value. Settings are adjusted via rotary switches, allowing both pickup value and dropout value (hysteresis) to be set. The hysteresis depends on the setpoint and must be considered during configuration. The start-up bypass activates only once upon applying auxiliary voltage to bridge start-up processes. The switching delay delays switching after exceeding the threshold, allowing short-term voltage spikes to be ignored.
Compatibility and accessories
The device is designed for monitoring DC and AC voltages in the range AC 25–250 V. It can also be used as an undervoltage relay, where the switching delay activates after falling below the hysteresis value. The measurement frequency extends up to 5 kHz, enabling detection of high-frequency signals. Galvanic isolation between auxiliary circuit and measurement circuit ensures safe separation of current circuits. The maximum permissible continuous voltage is 500 V AC or 450 V DC.
Mounting and installation
The relay is mounted in enclosures and features a fixed terminal block with screw terminals. Mounting is done in standard control panels with a width of 22.5 mm. Connection terminals are clearly labeled, with terminals Z1, Z2, Z3 designated for the remote potentiometer. During installation, ensure that the remote potentiometer is connected earth-free and potential-free, as it is not galvanically isolated from the measurement circuit. Terminal e" should be connected to "N", "- or GND to avoid phase voltages on the remote potentiometer.
Advantages in operation
Early detection of voltage anomalies enables preventive maintenance and prevents failures. LED indicators provide quick insight into the operational status. Switching delay and start-up bypass ensure reliable and disturbance-free operation. Galvanic isolation between auxiliary and measurement circuits increases safety. The device complies with standards IEC/EN 60255-1 and IEC/EN 60947-1 and is certified with CCC approval.
| Technical data | |
| 1- / 3-phase | 1 |
| Enclosure design | Switch cabinet |
| Nominal voltage max. | AC 500 V, DC 450 V |
| Output contacts | 2 C/O contacts |
| Width | 22,5 mm |
| Type | MK 9054N |
| Variant | |
| Auxiliary voltage | AC/DC 80 - 230 V |
| Contact equipping | 2 changeover contacts |
| Measuring range | AC 25 - 250 V |
| Operate delay | 0,1 - 20 s |
| Switching delay | 0 - 20 s |
| Terminal type | fixed terminal block with screw terminal |
| Approvals and Markings | CCC |
| Variant | Overvoltage relay. Energized on trip. With remote potentiometer |
Questions & answers
What is the delivery time of Dold 0065944 MK9054N.12/110 AC25-250V Tv=0-20S voltage relay AC/DC80-230V Ta=0.1-20S?
The article Dold 0065944 MK9054N.12/110 AC25-250V Tv=0-20S voltage relay AC/DC80-230V Ta=0.1-20S is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0065944 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0065944 MK9054N.12/110 AC25-250V Tv=0-20S voltage relay AC/DC80-230V Ta=0.1-20S always at the best possible price. We can give you a discount of 2% on Dold 0065944 MK9054N.12/110 AC25-250V Tv=0-20S voltage relay AC/DC80-230V Ta=0.1-20S if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0065944 MK9054N.12/110 AC25-250V Tv=0-20S voltage relay AC/DC80-230V Ta=0.1-20S we can offer you a price of 278,25 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.