Dold 0065944, EAN: 4030641659448

Dold 0065944 voltage relay AC25-250V Tv=0-20S

Dold 0065944 voltage relay AC25-250V Tv=0-20S

Lieske Part No. 1002180
Mfg Part No 0065944
EAN-Code 4030641659448
Manufacturer Dold
Here only 291,36 EUR
346,72 EUR incl. VAT

Further information for Dold 0065944 voltage relay AC25-250V Tv=0-20S

Technical data
1- / 3-phase1
Enclosure designSwitch cabinet
Nominal voltage max.AC 500 V, DC 450 V
Output contacts2 C/O contacts
Width22,5 mm
TypeMK 9054N
Variant
Auxiliary voltageAC/DC 80 - 230 V
Contact equipping2 changeover contacts
Measuring rangeAC 25 - 250 V
Operate delay0,1 - 20 s
Switching delay0 - 20 s
Terminal typefixed terminal block with screw terminal
Approvals and MarkingsCCC
VariantOvervoltage relay. Energized on trip. With remote potentiometer
The Dold voltage relay MK9054N.12/110 AC25-250V Tv=0-20S is an overvoltage relay of the VARIMETER series, designed for monitoring single-phase DC and AC voltage networks in industrial applications. The device operates on the operating current principle and is designed for use in enclosures. It features a fixed terminal block with screw terminals and a width of 22.5 mm, making it suitable for standard control panels. Device settings are adjusted via rotary switches on the front, ensuring simple and user-friendly configuration.

Applications
This relay is designed for continuous voltage monitoring in the range AC 25–250 V. It is used for early detection of voltage fluctuations to prevent damage to electrical systems and equipment. Applications are particularly in industrial environments where high operational safety and reliability are required. The integrated switching delay of 0 to 20 seconds enables differentiated response to short-term voltage spikes, avoiding false tripping. The pickup delay of 0.1 to 20 seconds ensures controlled response after reaching the setpoint.

Functions and equipment in detail
The device features 2 changeover contacts as output contacts, which can be used to control auxiliary circuits or warning signals. The contacts are rated for a maximum nominal voltage of AC 500 V and DC 450 V. The auxiliary voltage is AC/DC 80–230 V, allowing flexible use in various network voltage conditions. An integrated remote potentiometer enables remote control of the pickup value, although the measurement circuit and remote potentiometer are not galvanically isolated. Terminal markings include auxiliary voltage (A1, A2), voltage input (e, f), and contacts (11, 12, 14 and 21, 22, 24). Indication is provided by a green LED for operational readiness and a yellow LED for contact status.

Technology explained simply
The relay measures the arithmetic mean of the rectified measurement voltage. For AC voltages, the device is calibrated to the RMS value. Settings are adjusted via rotary switches, allowing both pickup value and dropout value (hysteresis) to be set. The hysteresis depends on the setpoint and must be considered during configuration. The start-up bypass activates only once upon applying auxiliary voltage to bridge start-up processes. The switching delay delays switching after exceeding the threshold, allowing short-term voltage spikes to be ignored.

Compatibility and accessories
The device is designed for monitoring DC and AC voltages in the range AC 25–250 V. It can also be used as an undervoltage relay, where the switching delay activates after falling below the hysteresis value. The measurement frequency extends up to 5 kHz, enabling detection of high-frequency signals. Galvanic isolation between auxiliary circuit and measurement circuit ensures safe separation of current circuits. The maximum permissible continuous voltage is 500 V AC or 450 V DC.

Mounting and installation
The relay is mounted in enclosures and features a fixed terminal block with screw terminals. Mounting is done in standard control panels with a width of 22.5 mm. Connection terminals are clearly labeled, with terminals Z1, Z2, Z3 designated for the remote potentiometer. During installation, ensure that the remote potentiometer is connected earth-free and potential-free, as it is not galvanically isolated from the measurement circuit. Terminal e" should be connected to "N", "- or GND to avoid phase voltages on the remote potentiometer.

Advantages in operation
Early detection of voltage anomalies enables preventive maintenance and prevents failures. LED indicators provide quick insight into the operational status. Switching delay and start-up bypass ensure reliable and disturbance-free operation. Galvanic isolation between auxiliary and measurement circuits increases safety. The device complies with standards IEC/EN 60255-1 and IEC/EN 60947-1 and is certified with CCC approval.